高精度微量热量计:仪器、程序和生化应用。

D K Steckler, R N Goldberg, Y B Tewari, T J Buckley
{"title":"高精度微量热量计:仪器、程序和生化应用。","authors":"D K Steckler, R N Goldberg, Y B Tewari, T J Buckley","doi":"10.6028/jres.091.018","DOIUrl":null,"url":null,"abstract":"<p><p>Apparatus and procedures used for high-precision microcalorimetric measurements are described. The calorimeter is of the heat-conduction type and utilizes semi-conductor thermoelectric modules. The bicompartmental reaction vessel is made of high-density polyethylene and holds about 0.5 mL of solution in each compartment. Imprecision of heat measurement is 0.2 percent when measuring 300 mJ of heat produced by a rapid chemical reaction. Three microcalorimeters are operated simultaneously using a microcomputer and a data acquisition system. Thermochemical and kinetic applications are described. The acquisition of data from an isoperibol solution calorimeter is also described.</p>","PeriodicalId":93321,"journal":{"name":"Journal of research of the National Bureau of Standards (1977)","volume":"91 3","pages":"113-121"},"PeriodicalIF":0.0000,"publicationDate":"1986-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6658430/pdf/jres-91-113.pdf","citationCount":"0","resultStr":"{\"title\":\"High Precision Microcalorimetry: Apparatus, Procedures, and Biochemical Applications.\",\"authors\":\"D K Steckler, R N Goldberg, Y B Tewari, T J Buckley\",\"doi\":\"10.6028/jres.091.018\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Apparatus and procedures used for high-precision microcalorimetric measurements are described. The calorimeter is of the heat-conduction type and utilizes semi-conductor thermoelectric modules. The bicompartmental reaction vessel is made of high-density polyethylene and holds about 0.5 mL of solution in each compartment. Imprecision of heat measurement is 0.2 percent when measuring 300 mJ of heat produced by a rapid chemical reaction. Three microcalorimeters are operated simultaneously using a microcomputer and a data acquisition system. Thermochemical and kinetic applications are described. The acquisition of data from an isoperibol solution calorimeter is also described.</p>\",\"PeriodicalId\":93321,\"journal\":{\"name\":\"Journal of research of the National Bureau of Standards (1977)\",\"volume\":\"91 3\",\"pages\":\"113-121\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1986-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC6658430/pdf/jres-91-113.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of research of the National Bureau of Standards (1977)\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.6028/jres.091.018\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of research of the National Bureau of Standards (1977)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.6028/jres.091.018","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

介绍了用于高精度微量热量测量的仪器和程序。热量计是热传导型的,并且利用半导体热电模块。双室反应容器由高密度聚乙烯制成,并且在每个室中容纳约0.5mL溶液。当测量由快速化学反应产生的300mJ的热量时,热量测量的不精确性为0.2%。使用微型计算机和数据采集系统同时操作三个微量热量计。介绍了热化学和动力学应用。还描述了从等容溶液量热计获取数据的过程。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
High Precision Microcalorimetry: Apparatus, Procedures, and Biochemical Applications.

Apparatus and procedures used for high-precision microcalorimetric measurements are described. The calorimeter is of the heat-conduction type and utilizes semi-conductor thermoelectric modules. The bicompartmental reaction vessel is made of high-density polyethylene and holds about 0.5 mL of solution in each compartment. Imprecision of heat measurement is 0.2 percent when measuring 300 mJ of heat produced by a rapid chemical reaction. Three microcalorimeters are operated simultaneously using a microcomputer and a data acquisition system. Thermochemical and kinetic applications are described. The acquisition of data from an isoperibol solution calorimeter is also described.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
The Temperature Dependence of Spectral Broadening in the Hg (61S0-63P1) Multiplet At High Optical Densities. Absolute Isotopic Abundance Ratio And Atomic Weight Of a Reference Sample of Gallium. Thermal Expansion of Platinum And Platinum-Rhodium Alloys. The Triple Point of Oxygen In Sealed Transportable Cells. A Multi-kilogram Capacity Calorimeter For Heterogeneous Materials.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1