{"title":"模拟研究设计选择对预测性病人监测报警算法观察性能的影响。","authors":"David O Nahmias,&nbsp;Christopher G Scully","doi":"10.1109/bhi50953.2021.9508544","DOIUrl":null,"url":null,"abstract":"<p><p>There are multiple study design choices to be selected in order to perform evaluations of predictive patient monitoring algorithms related to the event and true positive alarm definitions (e.g., how far ahead of the event is a true positive alarm). Often, passively collected patient monitoring datasets from clinical environments are available to perform these types of studies, so that the effects of different study design choices can be simulated to evaluate the robustness of an algorithm to those choices. Here, we simulate the effects of varying alarm and event definition criteria on the reported performance of the early warning score to predict hypotensive events. A total of 432 combinations of study design choices were simulated. Area under the receiver-operating characteristic curve varied from greater than 0.8 to less than 0.5 by adjusting alarm and event definition criteria. Traditional metrics for evaluating diagnostic systems were modulated across a wide range by adjusting study design choices for a predictive algorithm using a patient monitoring dataset. This highlights the importance of examining study design choices for new predictive patient monitoring algorithms and presents an approach to simulate different study designs with retrospective patient monitoring data as part of a robustness evaluation.</p>","PeriodicalId":72024,"journal":{"name":"... IEEE-EMBS International Conference on Biomedical and Health Informatics. IEEE-EMBS International Conference on Biomedical and Health Informatics","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8392319/pdf/nihms-1734184.pdf","citationCount":"0","resultStr":"{\"title\":\"Simulating Study Design Choice Effects on Observed Performance of Predictive Patient Monitoring Alarm Algorithms.\",\"authors\":\"David O Nahmias,&nbsp;Christopher G Scully\",\"doi\":\"10.1109/bhi50953.2021.9508544\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>There are multiple study design choices to be selected in order to perform evaluations of predictive patient monitoring algorithms related to the event and true positive alarm definitions (e.g., how far ahead of the event is a true positive alarm). Often, passively collected patient monitoring datasets from clinical environments are available to perform these types of studies, so that the effects of different study design choices can be simulated to evaluate the robustness of an algorithm to those choices. Here, we simulate the effects of varying alarm and event definition criteria on the reported performance of the early warning score to predict hypotensive events. A total of 432 combinations of study design choices were simulated. Area under the receiver-operating characteristic curve varied from greater than 0.8 to less than 0.5 by adjusting alarm and event definition criteria. Traditional metrics for evaluating diagnostic systems were modulated across a wide range by adjusting study design choices for a predictive algorithm using a patient monitoring dataset. This highlights the importance of examining study design choices for new predictive patient monitoring algorithms and presents an approach to simulate different study designs with retrospective patient monitoring data as part of a robustness evaluation.</p>\",\"PeriodicalId\":72024,\"journal\":{\"name\":\"... IEEE-EMBS International Conference on Biomedical and Health Informatics. IEEE-EMBS International Conference on Biomedical and Health Informatics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8392319/pdf/nihms-1734184.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"... IEEE-EMBS International Conference on Biomedical and Health Informatics. IEEE-EMBS International Conference on Biomedical and Health Informatics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1109/bhi50953.2021.9508544\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/8/10 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"... IEEE-EMBS International Conference on Biomedical and Health Informatics. IEEE-EMBS International Conference on Biomedical and Health Informatics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1109/bhi50953.2021.9508544","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/8/10 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

为了对与事件和真阳性警报定义(例如,事件发生前多远是真阳性警报)相关的预测性患者监测算法进行评估,需要选择多种研究设计选择。通常,从临床环境中被动收集的患者监测数据集可用于执行这些类型的研究,因此可以模拟不同研究设计选择的效果,以评估算法对这些选择的鲁棒性。在这里,我们模拟了不同的报警和事件定义标准对早期预警评分报告性能的影响,以预测低血压事件。总共模拟了432种研究设计选择组合。通过调整报警和事件定义标准,接收器工作特征曲线下的面积从大于0.8变化到小于0.5。通过调整使用患者监测数据集的预测算法的研究设计选择,对评估诊断系统的传统指标进行了大范围的调整。这突出了研究设计选择对新的预测性患者监测算法的重要性,并提出了一种方法,以回顾性患者监测数据模拟不同的研究设计,作为鲁棒性评估的一部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Simulating Study Design Choice Effects on Observed Performance of Predictive Patient Monitoring Alarm Algorithms.

There are multiple study design choices to be selected in order to perform evaluations of predictive patient monitoring algorithms related to the event and true positive alarm definitions (e.g., how far ahead of the event is a true positive alarm). Often, passively collected patient monitoring datasets from clinical environments are available to perform these types of studies, so that the effects of different study design choices can be simulated to evaluate the robustness of an algorithm to those choices. Here, we simulate the effects of varying alarm and event definition criteria on the reported performance of the early warning score to predict hypotensive events. A total of 432 combinations of study design choices were simulated. Area under the receiver-operating characteristic curve varied from greater than 0.8 to less than 0.5 by adjusting alarm and event definition criteria. Traditional metrics for evaluating diagnostic systems were modulated across a wide range by adjusting study design choices for a predictive algorithm using a patient monitoring dataset. This highlights the importance of examining study design choices for new predictive patient monitoring algorithms and presents an approach to simulate different study designs with retrospective patient monitoring data as part of a robustness evaluation.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Stratification and Survival Prediction for Amyotrophic Lateral Sclerosis Patients Transcutaneous Cervical Vagus Nerve Stimulation Reduces Respiratory Variability in the Context of Opioid Withdrawal. Genomics transformer for diagnosing Parkinson's disease. Transcutaneous Cervical Vagus Nerve Stimulation Lengthens Exhalation in the Context of Traumatic Stress. Analysis of Regions of Interest and Distractor Regions in Breast Biopsy Images.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1