{"title":"运动机能胶带适度地增加皮肤血流量,而不考虑胶带的应用技术。","authors":"Daniel H Craighead,&nbsp;Sean W Shank,&nbsp;Kyle M Volz,&nbsp;Lacy M Alexander","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Kinesiology tape (KNT) is commonly used for injury prevention and as part of rehabilitation to treat muscle and joint pain. KNT is purported to increase local blood flow by lifting the skin and reducing local pressure. Whether or not skin blood flow is increased by KNT is not presently known. We carried out 2 experiments to elucidate the effects of KNT on skin blood flow. Protocol 1: KNT was applied to the skin at 0%, 25%, 50%, and 100% relative tension. Red cell flux, an index of skin blood flow, was measured by laser Doppler flowmetry (LDF) at each site and at a no-tape control site. There was an overall effect of tape on cutaneous vascular conductance (CVC: LDF/MAP) (KNT: 0.12 (95% confidence interval: 0.10, 0.14), control 0.08 (0.07, 0.10) flux•mmHg<sup>-1</sup>; p<0.01), but no effect of tension (all p>0.05). Subjects kept KNT on for 3 days then returned for follow-up testing. CVC was not changed after 3 days of KNT application (p=0.07). Protocol 2: KNT was applied to the skin with and without convolutions. There was an overall effect of tape on CVC (KNT: 0.30 (0.21, 0.39), control 0.15 (0.09, 0.21) flux•mmHg<sup>-1</sup>; p=0.03), but no difference between KNT applied with or without convolutions (all p>0.05). These data suggest that KNT modestly increases microvascular blood flow, regardless of tension or presence of convolutions.</p>","PeriodicalId":93317,"journal":{"name":"Journal of performance health research","volume":"1 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2017-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8439387/pdf/nihms937340.pdf","citationCount":"0","resultStr":"{\"title\":\"Kinesiology tape modestly increases skin blood flow regardless of tape application technique.\",\"authors\":\"Daniel H Craighead,&nbsp;Sean W Shank,&nbsp;Kyle M Volz,&nbsp;Lacy M Alexander\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Kinesiology tape (KNT) is commonly used for injury prevention and as part of rehabilitation to treat muscle and joint pain. KNT is purported to increase local blood flow by lifting the skin and reducing local pressure. Whether or not skin blood flow is increased by KNT is not presently known. We carried out 2 experiments to elucidate the effects of KNT on skin blood flow. Protocol 1: KNT was applied to the skin at 0%, 25%, 50%, and 100% relative tension. Red cell flux, an index of skin blood flow, was measured by laser Doppler flowmetry (LDF) at each site and at a no-tape control site. There was an overall effect of tape on cutaneous vascular conductance (CVC: LDF/MAP) (KNT: 0.12 (95% confidence interval: 0.10, 0.14), control 0.08 (0.07, 0.10) flux•mmHg<sup>-1</sup>; p<0.01), but no effect of tension (all p>0.05). Subjects kept KNT on for 3 days then returned for follow-up testing. CVC was not changed after 3 days of KNT application (p=0.07). Protocol 2: KNT was applied to the skin with and without convolutions. There was an overall effect of tape on CVC (KNT: 0.30 (0.21, 0.39), control 0.15 (0.09, 0.21) flux•mmHg<sup>-1</sup>; p=0.03), but no difference between KNT applied with or without convolutions (all p>0.05). These data suggest that KNT modestly increases microvascular blood flow, regardless of tension or presence of convolutions.</p>\",\"PeriodicalId\":93317,\"journal\":{\"name\":\"Journal of performance health research\",\"volume\":\"1 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2017-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8439387/pdf/nihms937340.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of performance health research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2017/5/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of performance health research","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2017/5/17 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

运动机能胶带(KNT)通常用于损伤预防和作为康复治疗肌肉和关节疼痛的一部分。KNT据称是通过提升皮肤和降低局部压力来增加局部血液流动。目前尚不清楚KNT是否会增加皮肤血流量。我们进行了两个实验来阐明KNT对皮肤血流的影响。方案1:KNT以0%、25%、50%和100%的相对张力作用于皮肤。采用激光多普勒血流仪(LDF)测量每个部位和无胶带对照部位的红细胞通量(皮肤血流指数)。胶带对皮肤血管传导(CVC: LDF/MAP)的总体影响(KNT: 0.12(95%可信区间:0.10,0.14),对照组0.08(0.07,0.10)通量•mmHg-1;p0.05)。受试者使用KNT 3天后返回进行后续测试。施用KNT 3 d后CVC无明显变化(p=0.07)。方案2:将KNT应用于有或没有卷曲的皮肤。胶带对CVC的总体影响(KNT: 0.30(0.21, 0.39),对照组:0.15 (0.09,0.21)flux•mmHg-1;p=0.03),但使用卷积或不使用卷积的KNT无差异(均p>0.05)。这些数据表明,KNT适度地增加微血管血流,而不管紧张或存在卷曲。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Kinesiology tape modestly increases skin blood flow regardless of tape application technique.

Kinesiology tape (KNT) is commonly used for injury prevention and as part of rehabilitation to treat muscle and joint pain. KNT is purported to increase local blood flow by lifting the skin and reducing local pressure. Whether or not skin blood flow is increased by KNT is not presently known. We carried out 2 experiments to elucidate the effects of KNT on skin blood flow. Protocol 1: KNT was applied to the skin at 0%, 25%, 50%, and 100% relative tension. Red cell flux, an index of skin blood flow, was measured by laser Doppler flowmetry (LDF) at each site and at a no-tape control site. There was an overall effect of tape on cutaneous vascular conductance (CVC: LDF/MAP) (KNT: 0.12 (95% confidence interval: 0.10, 0.14), control 0.08 (0.07, 0.10) flux•mmHg-1; p<0.01), but no effect of tension (all p>0.05). Subjects kept KNT on for 3 days then returned for follow-up testing. CVC was not changed after 3 days of KNT application (p=0.07). Protocol 2: KNT was applied to the skin with and without convolutions. There was an overall effect of tape on CVC (KNT: 0.30 (0.21, 0.39), control 0.15 (0.09, 0.21) flux•mmHg-1; p=0.03), but no difference between KNT applied with or without convolutions (all p>0.05). These data suggest that KNT modestly increases microvascular blood flow, regardless of tension or presence of convolutions.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Kinesiology tape modestly increases skin blood flow regardless of tape application technique. Kinesiology tape modestly increases skin blood flow regardless of tape application technique.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1