{"title":"全主动脉弓修复术中吻合口远端止血的救助方法。","authors":"Takashi Yamauchi","doi":"10.5761/atcs.nm.21-00228","DOIUrl":null,"url":null,"abstract":"<p><p>Intraoperative bleeding from the distal anastomotic site during graft replacement of the arch to distal arch via median sternotomy to treat an aortic aneurysm is sometimes difficult to control because of the limited distal view. I herein report a case in which I addressed this uncontrollable bleeding using a commercialized frozen elephant trunk.</p>","PeriodicalId":8037,"journal":{"name":"Annals of Thoracic and Cardiovascular Surgery","volume":"28 3","pages":"236-238"},"PeriodicalIF":1.1000,"publicationDate":"2022-06-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/85/0d/atcs-28-236.PMC9209892.pdf","citationCount":"0","resultStr":"{\"title\":\"Bailout Solution for Hemostasis from Distal Anastomotic Site during Total Aortic Arch Repair.\",\"authors\":\"Takashi Yamauchi\",\"doi\":\"10.5761/atcs.nm.21-00228\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Intraoperative bleeding from the distal anastomotic site during graft replacement of the arch to distal arch via median sternotomy to treat an aortic aneurysm is sometimes difficult to control because of the limited distal view. I herein report a case in which I addressed this uncontrollable bleeding using a commercialized frozen elephant trunk.</p>\",\"PeriodicalId\":8037,\"journal\":{\"name\":\"Annals of Thoracic and Cardiovascular Surgery\",\"volume\":\"28 3\",\"pages\":\"236-238\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2022-06-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/85/0d/atcs-28-236.PMC9209892.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of Thoracic and Cardiovascular Surgery\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.5761/atcs.nm.21-00228\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/12/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Thoracic and Cardiovascular Surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.5761/atcs.nm.21-00228","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/12/16 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
Bailout Solution for Hemostasis from Distal Anastomotic Site during Total Aortic Arch Repair.
Intraoperative bleeding from the distal anastomotic site during graft replacement of the arch to distal arch via median sternotomy to treat an aortic aneurysm is sometimes difficult to control because of the limited distal view. I herein report a case in which I addressed this uncontrollable bleeding using a commercialized frozen elephant trunk.