无角膜异常白内障患者B/F比值分布及其对眼参数的影响

IF 1.2 4区 医学 Q4 MEDICINE, RESEARCH & EXPERIMENTAL Clinical and Investigative Medicine Pub Date : 2021-12-31 DOI:10.25011/cim.v44i4.37197
Michael Deng, Lina Lan, Tianhui Chen, Min Zhang, Jiahui Chen, Qinghe Jing, Yongxiang Jiang
{"title":"无角膜异常白内障患者B/F比值分布及其对眼参数的影响","authors":"Michael Deng,&nbsp;Lina Lan,&nbsp;Tianhui Chen,&nbsp;Min Zhang,&nbsp;Jiahui Chen,&nbsp;Qinghe Jing,&nbsp;Yongxiang Jiang","doi":"10.25011/cim.v44i4.37197","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the distribution of the posterior-anterior corneal radius ratio (B/F ratio; posterior corneal radius/anterior corneal radius) in patients without corneal abnormalities, and to investigate which parameters affect this ratio.</p><p><strong>Methods: </strong>Five thousand eyes from 5,000 patients who underwent cataract surgery were recruited to this study. We explored the linear relationship between B/F ratio and 13 variables using Principal Component-Multivariate Linear Regression Analysis.</p><p><strong>Results: </strong>The B/F ratio was negatively correlated with the difference between simulated keratometry (SimK) and true net power (TNP), central corneal thickness, spherical aberration (SA), and posterior corneal astigmatism and positively correlated with posterior corneal radius, corneal posterior surface, axial length (AL) and anterior corneal radius. Several variables (central corneal thickness, difference between SimK and TNP and asphericity coefficient (Q-value) of the posterior corneal surface) had the highest loading on the final score. B/F ratio reflects the refractive state and anatomical structure of the cornea: thus, higher B/F ratios were associated with larger posterior corneal surface curvature radius, longer axial length, thinner central corneal thickness, lower high order aberrations of the cornea and SA, and the numerical difference between simK and TNP gradually reduced. In clinical practice, for patients with lower B/F ratio, special care should be taken in the choice of system used for intraocular lens (IOL) measurements.</p>","PeriodicalId":50683,"journal":{"name":"Clinical and Investigative Medicine","volume":null,"pages":null},"PeriodicalIF":1.2000,"publicationDate":"2021-12-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of the B/F Ratio Distribution of Cataract Patients Without Corneal Abnormalities and Its Effect on Ocular Parameters.\",\"authors\":\"Michael Deng,&nbsp;Lina Lan,&nbsp;Tianhui Chen,&nbsp;Min Zhang,&nbsp;Jiahui Chen,&nbsp;Qinghe Jing,&nbsp;Yongxiang Jiang\",\"doi\":\"10.25011/cim.v44i4.37197\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To evaluate the distribution of the posterior-anterior corneal radius ratio (B/F ratio; posterior corneal radius/anterior corneal radius) in patients without corneal abnormalities, and to investigate which parameters affect this ratio.</p><p><strong>Methods: </strong>Five thousand eyes from 5,000 patients who underwent cataract surgery were recruited to this study. We explored the linear relationship between B/F ratio and 13 variables using Principal Component-Multivariate Linear Regression Analysis.</p><p><strong>Results: </strong>The B/F ratio was negatively correlated with the difference between simulated keratometry (SimK) and true net power (TNP), central corneal thickness, spherical aberration (SA), and posterior corneal astigmatism and positively correlated with posterior corneal radius, corneal posterior surface, axial length (AL) and anterior corneal radius. Several variables (central corneal thickness, difference between SimK and TNP and asphericity coefficient (Q-value) of the posterior corneal surface) had the highest loading on the final score. B/F ratio reflects the refractive state and anatomical structure of the cornea: thus, higher B/F ratios were associated with larger posterior corneal surface curvature radius, longer axial length, thinner central corneal thickness, lower high order aberrations of the cornea and SA, and the numerical difference between simK and TNP gradually reduced. In clinical practice, for patients with lower B/F ratio, special care should be taken in the choice of system used for intraocular lens (IOL) measurements.</p>\",\"PeriodicalId\":50683,\"journal\":{\"name\":\"Clinical and Investigative Medicine\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.2000,\"publicationDate\":\"2021-12-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Clinical and Investigative Medicine\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.25011/cim.v44i4.37197\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"MEDICINE, RESEARCH & EXPERIMENTAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Investigative Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.25011/cim.v44i4.37197","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"MEDICINE, RESEARCH & EXPERIMENTAL","Score":null,"Total":0}
引用次数: 0

摘要

目的:评价角膜后前侧半径比(B/F ratio;无角膜异常患者的后角膜半径/前角膜半径),并探讨哪些参数影响这一比例。方法:从5000例白内障手术患者中选取5000只眼睛作为研究对象。采用主成分-多元线性回归分析方法探讨了资产负债率与13个变量之间的线性关系。结果:B/F比值与模拟角膜度数(SimK)与真净度数(TNP)之差、角膜中央厚度、球差(SA)、角膜后散光呈负相关,与角膜后半径、角膜后表面、角膜轴长(AL)、角膜前半径呈正相关。几个变量(角膜中央厚度、SimK与TNP之差和角膜后表面非球面系数(q值))对最终评分的影响最大。B/F比值反映了角膜的屈光状态和解剖结构,因此,B/F比值越高,角膜后表面曲率半径越大,角膜轴向长度越长,角膜中央厚度越薄,角膜高阶像差和SA越低,simK与TNP的数值差异逐渐减小。在临床实践中,对于B/F比较低的患者,在选择人工晶状体(IOL)测量系统时应特别注意。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Evaluation of the B/F Ratio Distribution of Cataract Patients Without Corneal Abnormalities and Its Effect on Ocular Parameters.

Purpose: To evaluate the distribution of the posterior-anterior corneal radius ratio (B/F ratio; posterior corneal radius/anterior corneal radius) in patients without corneal abnormalities, and to investigate which parameters affect this ratio.

Methods: Five thousand eyes from 5,000 patients who underwent cataract surgery were recruited to this study. We explored the linear relationship between B/F ratio and 13 variables using Principal Component-Multivariate Linear Regression Analysis.

Results: The B/F ratio was negatively correlated with the difference between simulated keratometry (SimK) and true net power (TNP), central corneal thickness, spherical aberration (SA), and posterior corneal astigmatism and positively correlated with posterior corneal radius, corneal posterior surface, axial length (AL) and anterior corneal radius. Several variables (central corneal thickness, difference between SimK and TNP and asphericity coefficient (Q-value) of the posterior corneal surface) had the highest loading on the final score. B/F ratio reflects the refractive state and anatomical structure of the cornea: thus, higher B/F ratios were associated with larger posterior corneal surface curvature radius, longer axial length, thinner central corneal thickness, lower high order aberrations of the cornea and SA, and the numerical difference between simK and TNP gradually reduced. In clinical practice, for patients with lower B/F ratio, special care should be taken in the choice of system used for intraocular lens (IOL) measurements.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Clinical and Investigative Medicine
Clinical and Investigative Medicine 医学-医学:研究与实验
CiteScore
1.50
自引率
12.50%
发文量
18
审稿时长
>12 weeks
期刊介绍: Clinical and Investigative Medicine (CIM), publishes original work in the field of Clinical Investigation. Original work includes clinical or laboratory investigations and clinical reports. Reviews include information for Continuing Medical Education (CME), narrative review articles, systematic reviews, and meta-analyses.
期刊最新文献
Clinical Application of CT Imaging Grading System in Upper Urinary Tract Calculi with Kidney Infection. Newsletter Fall 2024: Clinician Investigator Trainee Association of Canada (CITAC). The Impact of miR-34a on Endothelial Cell Viability and Apoptosis in Ischemic Stroke: Unraveling the MTHFR-Homocysteine Pathway. Young Investigator Interview with CSCI Awardee, Dr. Kenneth Rockwood. Global Trends and Frontier in Research on Pancreatic Alpha Cells: A Bibliometric Analysis from 2013 to 2023.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1