{"title":"轻度认知障碍的听觉 P50 门控:病例对照研究","authors":"Weidong Song, Xiaohui Hu, Guohua Xie, Wentao Lai, Yang Wang, Donghui Wu","doi":"10.1177/15333175211068966","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective</b>: Auditory P50 gating changed might be a neurophysiological biomarker of the diagnosis of Mild Cognitive Impairment (MCI). We aimed to determine the impact of MCI in auditory P50 gating. <b>Methods</b>: All recruited participants completed structured questionnaires and finished auditory P50 gating measure. Results: A total of 20 MCI patients and 17 controls had been recruited. MCI patients had a significant higher reduction of P50 gating at Fz site, when compared to controls (1.21 ± .68 vs .66 ± .37, P = .00). Zero point five was the best cut off point to distinguish MCI and control of auditory P50 gating S2/S1 at Fz site. The P50 average amplitude at Pz site in MCI patients was significantly higher than controls (2.62 ± 1.20 vs 1.70 ± .74, P = .01). <b>Conclusion</b>: MCI patients might have impaired the ability of inhibiting the repeated stimulus.</p>","PeriodicalId":50816,"journal":{"name":"American Journal of Alzheimers Disease and Other Dementias","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10623964/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Auditory P50 Gating in Mild Cognitive Impairment: A Case-Control Study.\",\"authors\":\"Weidong Song, Xiaohui Hu, Guohua Xie, Wentao Lai, Yang Wang, Donghui Wu\",\"doi\":\"10.1177/15333175211068966\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b>Objective</b>: Auditory P50 gating changed might be a neurophysiological biomarker of the diagnosis of Mild Cognitive Impairment (MCI). We aimed to determine the impact of MCI in auditory P50 gating. <b>Methods</b>: All recruited participants completed structured questionnaires and finished auditory P50 gating measure. Results: A total of 20 MCI patients and 17 controls had been recruited. MCI patients had a significant higher reduction of P50 gating at Fz site, when compared to controls (1.21 ± .68 vs .66 ± .37, P = .00). Zero point five was the best cut off point to distinguish MCI and control of auditory P50 gating S2/S1 at Fz site. The P50 average amplitude at Pz site in MCI patients was significantly higher than controls (2.62 ± 1.20 vs 1.70 ± .74, P = .01). <b>Conclusion</b>: MCI patients might have impaired the ability of inhibiting the repeated stimulus.</p>\",\"PeriodicalId\":50816,\"journal\":{\"name\":\"American Journal of Alzheimers Disease and Other Dementias\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10623964/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American Journal of Alzheimers Disease and Other Dementias\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/15333175211068966\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CLINICAL NEUROLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Alzheimers Disease and Other Dementias","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/15333175211068966","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
The Auditory P50 Gating in Mild Cognitive Impairment: A Case-Control Study.
Objective: Auditory P50 gating changed might be a neurophysiological biomarker of the diagnosis of Mild Cognitive Impairment (MCI). We aimed to determine the impact of MCI in auditory P50 gating. Methods: All recruited participants completed structured questionnaires and finished auditory P50 gating measure. Results: A total of 20 MCI patients and 17 controls had been recruited. MCI patients had a significant higher reduction of P50 gating at Fz site, when compared to controls (1.21 ± .68 vs .66 ± .37, P = .00). Zero point five was the best cut off point to distinguish MCI and control of auditory P50 gating S2/S1 at Fz site. The P50 average amplitude at Pz site in MCI patients was significantly higher than controls (2.62 ± 1.20 vs 1.70 ± .74, P = .01). Conclusion: MCI patients might have impaired the ability of inhibiting the repeated stimulus.
期刊介绍:
American Journal of Alzheimer''s Disease and other Dementias® (AJADD) is for professionals on the frontlines of Alzheimer''s care, dementia, and clinical depression--especially physicians, nurses, psychiatrists, administrators, and other healthcare specialists who manage patients with dementias and their families. This journal is a member of the Committee on Publication Ethics (COPE).