Nathalie I Bouwer, Crista Liesting, Marcel J M Kofflard, Jasper J Brugts, Marc C J Kock, Jos J E M Kitzen, Mark-David Levin, Eric Boersma
{"title":"2d超声心动图与心脏MRI应变:一项接受曲妥珠单抗治疗的her2阳性乳腺癌患者的前瞻性队列研究","authors":"Nathalie I Bouwer, Crista Liesting, Marcel J M Kofflard, Jasper J Brugts, Marc C J Kock, Jos J E M Kitzen, Mark-David Levin, Eric Boersma","doi":"10.1186/s12947-021-00266-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>We aimed to study the predictive value of early two-dimensional echocardiography (2DE) speckle tracking (ST) for left ventricular ejection fraction (LVEF) changes during trastuzumab treatment for HER2-positive breast cancer.</p><p><strong>Methods: </strong>HER2-positive breast cancer patients receiving trastuzumab, with or without anthracycline, underwent 2DE-ST at baseline and after 3 and 6 months (m) trastuzumab. Cardiac magnetic resonance (CMR) imaging (with ST) was performed at baseline and 6 m. We studied the correlation between 2DE-ST- and CMR-derived global longitudinal strain (GLS) and global radial strain (GRS) measured at the same time. Additionally, we associated baseline and 3 m 2DE-ST measurements with later CMR-LVEF, and with cardiotoxicity, defined as CMR-LVEF < 45% and/or absolute decline > 10% during trastuzumab.</p><p><strong>Results: </strong>Forty-seven patients were included. Median baseline LVEF was 60.4%. GLS measurements based on 2DE-ST and CMR showed weak correlation (Pearson's r = 0.33; p = 0.041); GRS measurements were uncorrelated (r = 0.09; p = 0.979). 2DE-LVEF at baseline and 3 m, and 2DE-ST-GLS at 3 m were predictive of CMR-LVEF at 6 m. In contrast, the change in 2DE-ST-GLS at 3 m was predictive of the change in CMR-LVEF at 6 m, whereas the change in 2DE-LVEF was not. Importantly, the 11 patients who developed cardiotoxicity (28%) had larger 2DE-ST-GLS change at 3 m than those who did not (median 5.2%-points versus 1.7%-points; odds ratio for 1% difference change 1.81, 95% confidence interval 1.11-2.93; p = 0.016; explained variance 0.34).</p><p><strong>Conclusions: </strong>Correlations between 2DE-ST and CMR-derived measurements are weak. Nevertheless, ST-measurements appeared useful to improve the performance of 2DE in predicting LVEF changes after 6 m of trastuzumab treatment.</p>","PeriodicalId":9613,"journal":{"name":"Cardiovascular Ultrasound","volume":"19 1","pages":"35"},"PeriodicalIF":1.9000,"publicationDate":"2021-11-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8576921/pdf/","citationCount":"6","resultStr":"{\"title\":\"2D-echocardiography vs cardiac MRI strain: a prospective cohort study in patients with HER2-positive breast cancer undergoing trastuzumab.\",\"authors\":\"Nathalie I Bouwer, Crista Liesting, Marcel J M Kofflard, Jasper J Brugts, Marc C J Kock, Jos J E M Kitzen, Mark-David Levin, Eric Boersma\",\"doi\":\"10.1186/s12947-021-00266-x\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>We aimed to study the predictive value of early two-dimensional echocardiography (2DE) speckle tracking (ST) for left ventricular ejection fraction (LVEF) changes during trastuzumab treatment for HER2-positive breast cancer.</p><p><strong>Methods: </strong>HER2-positive breast cancer patients receiving trastuzumab, with or without anthracycline, underwent 2DE-ST at baseline and after 3 and 6 months (m) trastuzumab. Cardiac magnetic resonance (CMR) imaging (with ST) was performed at baseline and 6 m. We studied the correlation between 2DE-ST- and CMR-derived global longitudinal strain (GLS) and global radial strain (GRS) measured at the same time. Additionally, we associated baseline and 3 m 2DE-ST measurements with later CMR-LVEF, and with cardiotoxicity, defined as CMR-LVEF < 45% and/or absolute decline > 10% during trastuzumab.</p><p><strong>Results: </strong>Forty-seven patients were included. Median baseline LVEF was 60.4%. GLS measurements based on 2DE-ST and CMR showed weak correlation (Pearson's r = 0.33; p = 0.041); GRS measurements were uncorrelated (r = 0.09; p = 0.979). 2DE-LVEF at baseline and 3 m, and 2DE-ST-GLS at 3 m were predictive of CMR-LVEF at 6 m. In contrast, the change in 2DE-ST-GLS at 3 m was predictive of the change in CMR-LVEF at 6 m, whereas the change in 2DE-LVEF was not. Importantly, the 11 patients who developed cardiotoxicity (28%) had larger 2DE-ST-GLS change at 3 m than those who did not (median 5.2%-points versus 1.7%-points; odds ratio for 1% difference change 1.81, 95% confidence interval 1.11-2.93; p = 0.016; explained variance 0.34).</p><p><strong>Conclusions: </strong>Correlations between 2DE-ST and CMR-derived measurements are weak. Nevertheless, ST-measurements appeared useful to improve the performance of 2DE in predicting LVEF changes after 6 m of trastuzumab treatment.</p>\",\"PeriodicalId\":9613,\"journal\":{\"name\":\"Cardiovascular Ultrasound\",\"volume\":\"19 1\",\"pages\":\"35\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2021-11-09\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8576921/pdf/\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Ultrasound\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12947-021-00266-x\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12947-021-00266-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 6
摘要
背景:我们旨在研究曲妥珠单抗治疗her2阳性乳腺癌期间,早期二维超声心动图(2DE)斑点追踪(ST)对左室射血分数(LVEF)变化的预测价值。方法:her2阳性乳腺癌患者接受曲妥珠单抗,联合或不联合蒽环类药物,在基线和曲妥珠单抗3个月和6个月(m)后接受2DE-ST。在基线和6 m时进行心脏磁共振(CMR)成像(带ST)。我们研究了2DE-ST-和cmr同时测量的全球纵向应变(GLS)和全球径向应变(GRS)之间的相关性。此外,我们将基线和3 m 2DE-ST测量与后来的CMR-LVEF和心脏毒性(定义为曲妥珠单抗期间CMR-LVEF为10%)相关联。结果:纳入47例患者。中位基线LVEF为60.4%。基于2DE-ST的GLS测量与CMR呈弱相关性(Pearson’s r = 0.33;p = 0.041);GRS测量值不相关(r = 0.09;p = 0.979)。基线和3m时的2DE-LVEF和3m时的2DE-ST-GLS可预测6m时的CMR-LVEF。相比之下,3 m时2DE-ST-GLS的变化可以预测6 m时CMR-LVEF的变化,而2DE-LVEF的变化则不能预测。重要的是,11名发生心脏毒性的患者(28%)在3 m时的2DE-ST-GLS变化大于未发生心脏毒性的患者(中位数5.2% vs 1.7%;1%差异变化的优势比为1.81,95%置信区间为1.11-2.93;p = 0.016;解释方差0.34)。结论:2DE-ST与cmr测量结果之间的相关性较弱。然而,st测量似乎有助于提高2DE预测曲妥珠单抗治疗6 m后LVEF变化的性能。
2D-echocardiography vs cardiac MRI strain: a prospective cohort study in patients with HER2-positive breast cancer undergoing trastuzumab.
Background: We aimed to study the predictive value of early two-dimensional echocardiography (2DE) speckle tracking (ST) for left ventricular ejection fraction (LVEF) changes during trastuzumab treatment for HER2-positive breast cancer.
Methods: HER2-positive breast cancer patients receiving trastuzumab, with or without anthracycline, underwent 2DE-ST at baseline and after 3 and 6 months (m) trastuzumab. Cardiac magnetic resonance (CMR) imaging (with ST) was performed at baseline and 6 m. We studied the correlation between 2DE-ST- and CMR-derived global longitudinal strain (GLS) and global radial strain (GRS) measured at the same time. Additionally, we associated baseline and 3 m 2DE-ST measurements with later CMR-LVEF, and with cardiotoxicity, defined as CMR-LVEF < 45% and/or absolute decline > 10% during trastuzumab.
Results: Forty-seven patients were included. Median baseline LVEF was 60.4%. GLS measurements based on 2DE-ST and CMR showed weak correlation (Pearson's r = 0.33; p = 0.041); GRS measurements were uncorrelated (r = 0.09; p = 0.979). 2DE-LVEF at baseline and 3 m, and 2DE-ST-GLS at 3 m were predictive of CMR-LVEF at 6 m. In contrast, the change in 2DE-ST-GLS at 3 m was predictive of the change in CMR-LVEF at 6 m, whereas the change in 2DE-LVEF was not. Importantly, the 11 patients who developed cardiotoxicity (28%) had larger 2DE-ST-GLS change at 3 m than those who did not (median 5.2%-points versus 1.7%-points; odds ratio for 1% difference change 1.81, 95% confidence interval 1.11-2.93; p = 0.016; explained variance 0.34).
Conclusions: Correlations between 2DE-ST and CMR-derived measurements are weak. Nevertheless, ST-measurements appeared useful to improve the performance of 2DE in predicting LVEF changes after 6 m of trastuzumab treatment.
期刊介绍:
Cardiovascular Ultrasound is an online journal, publishing peer-reviewed: original research; authoritative reviews; case reports on challenging and/or unusual diagnostic aspects; and expert opinions on new techniques and technologies. We are particularly interested in articles that include relevant images or video files, which provide an additional dimension to published articles and enhance understanding.
As an open access journal, Cardiovascular Ultrasound ensures high visibility for authors in addition to providing an up-to-date and freely available resource for the community. The journal welcomes discussion, and provides a forum for publishing opinion and debate ranging from biology to engineering to clinical echocardiography, with both speed and versatility.