M Jurich, S Svarzchtein, F Bidolegui, S Pereira, E Fuentes, E Wagner, D Godoy, A Cid-Casteulani
{"title":"[高能胫骨板骨折的放射学和功能结果]。","authors":"M Jurich, S Svarzchtein, F Bidolegui, S Pereira, E Fuentes, E Wagner, D Godoy, A Cid-Casteulani","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>The tibial plateau fractures due to high-energy mechanisms are serious injuries that occur on a load bearing joint. These are difficult to approach because, also affect the bone structure of the leg, they usually have associated soft tissue injuries.</p><p><strong>Objective: </strong>To evaluate the radiological and functional results of high-energy tibial plateau fractures with a minimum follow-up of one year.</p><p><strong>Material and methods: </strong>Retrospective, observational and multicenter study. Analysis of radiological and functional outcomes in the treatment of high-energy tibial plateau fractures, treated by open reduction and internal fixation (ORIF) between 2014 and 2019.</p><p><strong>Results: </strong>54 fractures treated by ORIF. Follow-up one year. 98.1% consolidation in 13 weeks on average. 83.4% without alterations of the axis in the coronal plane. 74% without postoperative joint widening. Functional scores: Lysholm 82.1 average points and Oxford Knee Score (OKS) 39.5 average points.</p><p><strong>Conclusion: </strong>The joint range of motion was reduced after a high-energy tibial plateau fracture, but with good functional results. The less off axis and less post-operative radiographic widening, the better results are obtained.</p>","PeriodicalId":7081,"journal":{"name":"Acta ortopedica mexicana","volume":"35 4","pages":"322-326"},"PeriodicalIF":0.0000,"publicationDate":"2021-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Radiological and functional results in high-energy tibial plate fractures].\",\"authors\":\"M Jurich, S Svarzchtein, F Bidolegui, S Pereira, E Fuentes, E Wagner, D Godoy, A Cid-Casteulani\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Introduction: </strong>The tibial plateau fractures due to high-energy mechanisms are serious injuries that occur on a load bearing joint. These are difficult to approach because, also affect the bone structure of the leg, they usually have associated soft tissue injuries.</p><p><strong>Objective: </strong>To evaluate the radiological and functional results of high-energy tibial plateau fractures with a minimum follow-up of one year.</p><p><strong>Material and methods: </strong>Retrospective, observational and multicenter study. Analysis of radiological and functional outcomes in the treatment of high-energy tibial plateau fractures, treated by open reduction and internal fixation (ORIF) between 2014 and 2019.</p><p><strong>Results: </strong>54 fractures treated by ORIF. Follow-up one year. 98.1% consolidation in 13 weeks on average. 83.4% without alterations of the axis in the coronal plane. 74% without postoperative joint widening. Functional scores: Lysholm 82.1 average points and Oxford Knee Score (OKS) 39.5 average points.</p><p><strong>Conclusion: </strong>The joint range of motion was reduced after a high-energy tibial plateau fracture, but with good functional results. The less off axis and less post-operative radiographic widening, the better results are obtained.</p>\",\"PeriodicalId\":7081,\"journal\":{\"name\":\"Acta ortopedica mexicana\",\"volume\":\"35 4\",\"pages\":\"322-326\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta ortopedica mexicana\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta ortopedica mexicana","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Radiological and functional results in high-energy tibial plate fractures].
Introduction: The tibial plateau fractures due to high-energy mechanisms are serious injuries that occur on a load bearing joint. These are difficult to approach because, also affect the bone structure of the leg, they usually have associated soft tissue injuries.
Objective: To evaluate the radiological and functional results of high-energy tibial plateau fractures with a minimum follow-up of one year.
Material and methods: Retrospective, observational and multicenter study. Analysis of radiological and functional outcomes in the treatment of high-energy tibial plateau fractures, treated by open reduction and internal fixation (ORIF) between 2014 and 2019.
Results: 54 fractures treated by ORIF. Follow-up one year. 98.1% consolidation in 13 weeks on average. 83.4% without alterations of the axis in the coronal plane. 74% without postoperative joint widening. Functional scores: Lysholm 82.1 average points and Oxford Knee Score (OKS) 39.5 average points.
Conclusion: The joint range of motion was reduced after a high-energy tibial plateau fracture, but with good functional results. The less off axis and less post-operative radiographic widening, the better results are obtained.