{"title":"角膜前段光学相干断层扫描评价角膜间环段位置。","authors":"Ebru Gorgun, Raciha Beril Kucumen, Nursal Melda Yenerel, Ferda Ciftci","doi":"10.3928/15428877-20120301-01","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and objective: </strong>To examine the exact position of implanted Keraring (Mediphacos, Belo Horizonte, Brazil) segments by high-resolution anterior segment optical coherence tomography (AS-OCT).</p><p><strong>Patients and methods: </strong>This study included 17 eyes of 13 patients with keratoconus who underwent uneventful intracorneal ring segment implantation with the aid of femtosecond laser. Eyes were evaluated by AS-OCT at the third postoperative month. Distance from the apex of the triangular cross-section of the ring segment to the anterior corneal surface and distances from two basal corners to the posterior corneal surface were measured.</p><p><strong>Results: </strong>Distance from apex to anterior corneal surface (263.1 ± 42.9 μm) was significantly smaller than target depth calculated intraoperatively (356.9 ± 35.7 μm, P < .001). Distance between outer basal corner and posterior corneal surface was significantly greater than distance between inner basal corner and posterior corneal surface.</p><p><strong>Conclusion: </strong>High-resolution AS-OCT is a rapid, convenient, and valuable technique in the follow-up of patients with implanted Keraring segments that may be helpful in predicting ring-related complications.</p>","PeriodicalId":54675,"journal":{"name":"Ophthalmic Surgery Lasers & Imaging","volume":" ","pages":"214-21"},"PeriodicalIF":0.0000,"publicationDate":"2012-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3928/15428877-20120301-01","citationCount":"21","resultStr":"{\"title\":\"Assessment of intrastromal corneal ring segment position with anterior segment optical coherence tomography.\",\"authors\":\"Ebru Gorgun, Raciha Beril Kucumen, Nursal Melda Yenerel, Ferda Ciftci\",\"doi\":\"10.3928/15428877-20120301-01\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and objective: </strong>To examine the exact position of implanted Keraring (Mediphacos, Belo Horizonte, Brazil) segments by high-resolution anterior segment optical coherence tomography (AS-OCT).</p><p><strong>Patients and methods: </strong>This study included 17 eyes of 13 patients with keratoconus who underwent uneventful intracorneal ring segment implantation with the aid of femtosecond laser. Eyes were evaluated by AS-OCT at the third postoperative month. Distance from the apex of the triangular cross-section of the ring segment to the anterior corneal surface and distances from two basal corners to the posterior corneal surface were measured.</p><p><strong>Results: </strong>Distance from apex to anterior corneal surface (263.1 ± 42.9 μm) was significantly smaller than target depth calculated intraoperatively (356.9 ± 35.7 μm, P < .001). Distance between outer basal corner and posterior corneal surface was significantly greater than distance between inner basal corner and posterior corneal surface.</p><p><strong>Conclusion: </strong>High-resolution AS-OCT is a rapid, convenient, and valuable technique in the follow-up of patients with implanted Keraring segments that may be helpful in predicting ring-related complications.</p>\",\"PeriodicalId\":54675,\"journal\":{\"name\":\"Ophthalmic Surgery Lasers & Imaging\",\"volume\":\" \",\"pages\":\"214-21\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3928/15428877-20120301-01\",\"citationCount\":\"21\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ophthalmic Surgery Lasers & Imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3928/15428877-20120301-01\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/3/8 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ophthalmic Surgery Lasers & Imaging","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3928/15428877-20120301-01","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/3/8 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 21
摘要
背景与目的:利用高分辨率前段光学相干断层扫描(AS-OCT)检测植入Keraring (Mediphacos, Belo Horizonte, Brazil)节段的准确位置。患者和方法:13例17眼圆锥角膜患者在飞秒激光辅助下行角膜内环段植入术。术后第3个月行AS-OCT检查。测量圆环段三角形截面顶点到角膜前表面的距离和两个基底角到角膜后表面的距离。结果:顶点到角膜前表面的距离(263.1±42.9 μm)明显小于术中计算的目标深度(356.9±35.7 μm), P < 0.001。外基底角到角膜后表面的距离显著大于内基底角到角膜后表面的距离。结论:高分辨率AS-OCT是一种快速、方便、有价值的技术,可用于预测植入Keraring节段患者的环相关并发症。
Assessment of intrastromal corneal ring segment position with anterior segment optical coherence tomography.
Background and objective: To examine the exact position of implanted Keraring (Mediphacos, Belo Horizonte, Brazil) segments by high-resolution anterior segment optical coherence tomography (AS-OCT).
Patients and methods: This study included 17 eyes of 13 patients with keratoconus who underwent uneventful intracorneal ring segment implantation with the aid of femtosecond laser. Eyes were evaluated by AS-OCT at the third postoperative month. Distance from the apex of the triangular cross-section of the ring segment to the anterior corneal surface and distances from two basal corners to the posterior corneal surface were measured.
Results: Distance from apex to anterior corneal surface (263.1 ± 42.9 μm) was significantly smaller than target depth calculated intraoperatively (356.9 ± 35.7 μm, P < .001). Distance between outer basal corner and posterior corneal surface was significantly greater than distance between inner basal corner and posterior corneal surface.
Conclusion: High-resolution AS-OCT is a rapid, convenient, and valuable technique in the follow-up of patients with implanted Keraring segments that may be helpful in predicting ring-related complications.
期刊介绍:
Ophthalmic Surgery, Lasers and Imaging, an official publication of ARVO/ISIE, provides clinically valuable, practical articles in the field of ophthalmology on a bimonthly basis. The Journal publishes original, peer-reviewed articles that delve into the entire spectrum of ophthalmic surgery and treatment, including experimental science, surgical techniques, and video surgical clips. Subscribers can also benefit from our featured On Line Advanced Release—read articles before they appear in the print issue!