评价学生在多用途软件数字化上蜡训练中的表现的评分标准。

IF 2.7 3区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE Journal of Advanced Prosthodontics Pub Date : 2022-08-01 Epub Date: 2022-08-29 DOI:10.4047/jap.2022.14.4.203
Takuya Mino, Yoko Kurosaki, Kana Tokumoto, Takaharu Higuchi, Shinichi Nakanoda, Ken Numoto, Ikue Tosa, Aya Kimura-Ono, Kenji Maekawa, Tae Hyung Kim, Takuo Kuboki
{"title":"评价学生在多用途软件数字化上蜡训练中的表现的评分标准。","authors":"Takuya Mino,&nbsp;Yoko Kurosaki,&nbsp;Kana Tokumoto,&nbsp;Takaharu Higuchi,&nbsp;Shinichi Nakanoda,&nbsp;Ken Numoto,&nbsp;Ikue Tosa,&nbsp;Aya Kimura-Ono,&nbsp;Kenji Maekawa,&nbsp;Tae Hyung Kim,&nbsp;Takuo Kuboki","doi":"10.4047/jap.2022.14.4.203","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The aim of this study was to introduce rating criteria to evaluate student performance in a newly developed, digital wax-up preclinical program for computer-aided design (CAD) of full-coverage crowns and preliminarily investigate the reliability and internal consistency of the rating system.</p><p><strong>Materials and methods: </strong>This study, conducted in 2017, enrolled 47 fifth-year dental students of Okayama University Dental School. Digital wax-up training included a fundamental practice using computer graphics (CG), multipurpose CAD software programs, and an advanced practice to execute a digital wax-up of the right mandibular second molar (#47). Each student's digital wax-up work (stereolithography data) was evaluated by two instructors using seven qualitative criteria. The total qualitative score (0-90) of the criteria was calculated. The total volumetric discrepancy between each student's digital wax-up work and a reference prepared by an instructor was automatically measured by the CAD software. The inter-rater reliability of each criterion was analyzed using a weighted kappa index. The relationship between the total volume discrepancy and the total qualitative score was analyzed using Spearman's correlation.</p><p><strong>Results: </strong>The weighted kappa values for the seven qualitative criteria ranged from 0.62 - 0.93. The total qualitative score and the total volumetric discrepancy were negatively correlated (ρ = -0.27, <i>P</i> = .09, respectively); however, this was not statistically significant.</p><p><strong>Conclusion: </strong>The established qualitative criteria to evaluate students' work showed sufficiently high inter-rater reliability; however, the digitally measured volumetric discrepancy could not sufficiently predict the total qualitative score.</p>","PeriodicalId":51291,"journal":{"name":"Journal of Advanced Prosthodontics","volume":null,"pages":null},"PeriodicalIF":2.7000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a1/6a/jap-14-203.PMC9444485.pdf","citationCount":"1","resultStr":"{\"title\":\"Rating criteria to evaluate student performance in digital wax-up training using multi-purpose software.\",\"authors\":\"Takuya Mino,&nbsp;Yoko Kurosaki,&nbsp;Kana Tokumoto,&nbsp;Takaharu Higuchi,&nbsp;Shinichi Nakanoda,&nbsp;Ken Numoto,&nbsp;Ikue Tosa,&nbsp;Aya Kimura-Ono,&nbsp;Kenji Maekawa,&nbsp;Tae Hyung Kim,&nbsp;Takuo Kuboki\",\"doi\":\"10.4047/jap.2022.14.4.203\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The aim of this study was to introduce rating criteria to evaluate student performance in a newly developed, digital wax-up preclinical program for computer-aided design (CAD) of full-coverage crowns and preliminarily investigate the reliability and internal consistency of the rating system.</p><p><strong>Materials and methods: </strong>This study, conducted in 2017, enrolled 47 fifth-year dental students of Okayama University Dental School. Digital wax-up training included a fundamental practice using computer graphics (CG), multipurpose CAD software programs, and an advanced practice to execute a digital wax-up of the right mandibular second molar (#47). Each student's digital wax-up work (stereolithography data) was evaluated by two instructors using seven qualitative criteria. The total qualitative score (0-90) of the criteria was calculated. The total volumetric discrepancy between each student's digital wax-up work and a reference prepared by an instructor was automatically measured by the CAD software. The inter-rater reliability of each criterion was analyzed using a weighted kappa index. The relationship between the total volume discrepancy and the total qualitative score was analyzed using Spearman's correlation.</p><p><strong>Results: </strong>The weighted kappa values for the seven qualitative criteria ranged from 0.62 - 0.93. The total qualitative score and the total volumetric discrepancy were negatively correlated (ρ = -0.27, <i>P</i> = .09, respectively); however, this was not statistically significant.</p><p><strong>Conclusion: </strong>The established qualitative criteria to evaluate students' work showed sufficiently high inter-rater reliability; however, the digitally measured volumetric discrepancy could not sufficiently predict the total qualitative score.</p>\",\"PeriodicalId\":51291,\"journal\":{\"name\":\"Journal of Advanced Prosthodontics\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2022-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a1/6a/jap-14-203.PMC9444485.pdf\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Advanced Prosthodontics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4047/jap.2022.14.4.203\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/8/29 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q1\",\"JCRName\":\"DENTISTRY, ORAL SURGERY & MEDICINE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Advanced Prosthodontics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4047/jap.2022.14.4.203","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/29 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 1

摘要

目的:本研究的目的是介绍评价学生在新开发的全覆盖冠计算机辅助设计(CAD)的数字打蜡临床前课程中的表现的评分标准,并初步探讨评分系统的可靠性和内部一致性。材料与方法:本研究于2017年进行,招募了47名冈山大学牙科学院的五年级牙科学生。数字上蜡训练包括使用计算机图形学(CG)的基本练习,多用途CAD软件程序,以及对右下颌第二磨牙进行数字上蜡的高级练习(#47)。每位学生的数字上蜡作业(立体光刻数据)由两名教师使用七个定性标准进行评估。计算各指标的总定性评分(0-90分)。由CAD软件自动测量每个学生的数字上蜡作业与教师准备的参考资料之间的总体积差异。使用加权kappa指数分析每个标准的评级间信度。采用Spearman相关分析了总容积差异与总定性评分之间的关系。结果:7个定性标准的加权kappa值范围为0.62 ~ 0.93。总定性评分与总容积差异呈负相关(ρ = -0.27, P = 0.09);然而,这在统计学上并不显著。结论:所建立的评价学生作业的定性标准具有足够高的信度;然而,数字测量的体积差异不能充分预测总定性评分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Rating criteria to evaluate student performance in digital wax-up training using multi-purpose software.

Purpose: The aim of this study was to introduce rating criteria to evaluate student performance in a newly developed, digital wax-up preclinical program for computer-aided design (CAD) of full-coverage crowns and preliminarily investigate the reliability and internal consistency of the rating system.

Materials and methods: This study, conducted in 2017, enrolled 47 fifth-year dental students of Okayama University Dental School. Digital wax-up training included a fundamental practice using computer graphics (CG), multipurpose CAD software programs, and an advanced practice to execute a digital wax-up of the right mandibular second molar (#47). Each student's digital wax-up work (stereolithography data) was evaluated by two instructors using seven qualitative criteria. The total qualitative score (0-90) of the criteria was calculated. The total volumetric discrepancy between each student's digital wax-up work and a reference prepared by an instructor was automatically measured by the CAD software. The inter-rater reliability of each criterion was analyzed using a weighted kappa index. The relationship between the total volume discrepancy and the total qualitative score was analyzed using Spearman's correlation.

Results: The weighted kappa values for the seven qualitative criteria ranged from 0.62 - 0.93. The total qualitative score and the total volumetric discrepancy were negatively correlated (ρ = -0.27, P = .09, respectively); however, this was not statistically significant.

Conclusion: The established qualitative criteria to evaluate students' work showed sufficiently high inter-rater reliability; however, the digitally measured volumetric discrepancy could not sufficiently predict the total qualitative score.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Advanced Prosthodontics
Journal of Advanced Prosthodontics DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
4.70
自引率
3.80%
发文量
25
期刊介绍: This journal aims to convey scientific and clinical progress in the field of prosthodontics and its related areas to many dental communities concerned with esthetic and functional restorations, occlusion, implants, prostheses, and biomaterials related to prosthodontics. This journal publishes • Original research data of high scientific merit in the field of diagnosis, function, esthetics and stomatognathic physiology related to prosthodontic rehabilitation, physiology and mechanics of occlusion, mechanical and biologic aspects of prosthodontic materials including dental implants. • Review articles by experts on controversies and new developments in prosthodontics. • Case reports if they provide or document new fundamental knowledge.
期刊最新文献
A novel brief questionnaire using a face rating scale to assess dental anxiety and fear. Clinical performance of implant-assisted removable partial dentures using implant surveyed crowns: a systematic review and meta-analysis. Effect of cement type, luting protocol, and ceramic abutment material on the shade of cemented titanium-based lithium disilicate crowns and surrounding peri-implant soft tissue: a spectrophotometric analysis. Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical study. Recording maximal intercuspation and border positions of the mandible with intraoral scanner using the acquisition software's multi-occlusion function.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1