Muhammad Nurhadi Rahman, Siswanto Agus Wilopo, Ova Emilia
{"title":"分娩阴道扩张器预防分娩时盆底损伤的疗效:一项方案研究。","authors":"Muhammad Nurhadi Rahman, Siswanto Agus Wilopo, Ova Emilia","doi":"10.29337/ijsp.179","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Vaginal birth may have a negative impact on nerve structure and function, pelvic floor muscle structure, and function. Reducing the risk of pelvic floor injuries during vaginal birth is one of the most effective ways to prevent labor morbidity in women. There is a lack of tools developed based on this approach, especially in Indonesia. Therefore, we aimed to know the efficacy of a vaginal dilator called Divabirth based on labor outcomes.</p><p><strong>Methods: </strong>This clinical study involved subjects who are randomly grouped in to the control and treatment groups. Subjects in the treatment group are told to utilize vaginal dilator devices for 20 minutes each session, a maximum of two sessions per day, lasting 5 minutes every cycle, from 35 weeks of gestation until delivery.</p><p><strong>Discussions: </strong>The current research contributes valuable information to developing a vaginal dilator intervention program for pregnant women to reduce perineal laceration and improve labor outcomes. It may also help to lower their medical and treatment expenditures. We expect its success to be a step forward in improving reproductive health status.</p><p><strong>Highlights: </strong>Vaginal birth may have negative impact on nerve and pelvic floor muscle structure and functionLack of tool has been developed to reduce the risk of pelvic floor injuries during vaginal birthA study protocol of vaginal dilator usage to know the efficacy based on labor outcomes.</p>","PeriodicalId":42077,"journal":{"name":"International Journal of Surgery Protocols","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2022-10-28","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9635326/pdf/","citationCount":"0","resultStr":"{\"title\":\"The Efficacy of Divabirth Vaginal Dilator to Prevent Pelvic Floor Trauma During Labor: A Protocol Study.\",\"authors\":\"Muhammad Nurhadi Rahman, Siswanto Agus Wilopo, Ova Emilia\",\"doi\":\"10.29337/ijsp.179\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Vaginal birth may have a negative impact on nerve structure and function, pelvic floor muscle structure, and function. Reducing the risk of pelvic floor injuries during vaginal birth is one of the most effective ways to prevent labor morbidity in women. There is a lack of tools developed based on this approach, especially in Indonesia. Therefore, we aimed to know the efficacy of a vaginal dilator called Divabirth based on labor outcomes.</p><p><strong>Methods: </strong>This clinical study involved subjects who are randomly grouped in to the control and treatment groups. Subjects in the treatment group are told to utilize vaginal dilator devices for 20 minutes each session, a maximum of two sessions per day, lasting 5 minutes every cycle, from 35 weeks of gestation until delivery.</p><p><strong>Discussions: </strong>The current research contributes valuable information to developing a vaginal dilator intervention program for pregnant women to reduce perineal laceration and improve labor outcomes. It may also help to lower their medical and treatment expenditures. We expect its success to be a step forward in improving reproductive health status.</p><p><strong>Highlights: </strong>Vaginal birth may have negative impact on nerve and pelvic floor muscle structure and functionLack of tool has been developed to reduce the risk of pelvic floor injuries during vaginal birthA study protocol of vaginal dilator usage to know the efficacy based on labor outcomes.</p>\",\"PeriodicalId\":42077,\"journal\":{\"name\":\"International Journal of Surgery Protocols\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2022-10-28\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9635326/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Surgery Protocols\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.29337/ijsp.179\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"SURGERY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Surgery Protocols","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.29337/ijsp.179","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"SURGERY","Score":null,"Total":0}
The Efficacy of Divabirth Vaginal Dilator to Prevent Pelvic Floor Trauma During Labor: A Protocol Study.
Background: Vaginal birth may have a negative impact on nerve structure and function, pelvic floor muscle structure, and function. Reducing the risk of pelvic floor injuries during vaginal birth is one of the most effective ways to prevent labor morbidity in women. There is a lack of tools developed based on this approach, especially in Indonesia. Therefore, we aimed to know the efficacy of a vaginal dilator called Divabirth based on labor outcomes.
Methods: This clinical study involved subjects who are randomly grouped in to the control and treatment groups. Subjects in the treatment group are told to utilize vaginal dilator devices for 20 minutes each session, a maximum of two sessions per day, lasting 5 minutes every cycle, from 35 weeks of gestation until delivery.
Discussions: The current research contributes valuable information to developing a vaginal dilator intervention program for pregnant women to reduce perineal laceration and improve labor outcomes. It may also help to lower their medical and treatment expenditures. We expect its success to be a step forward in improving reproductive health status.
Highlights: Vaginal birth may have negative impact on nerve and pelvic floor muscle structure and functionLack of tool has been developed to reduce the risk of pelvic floor injuries during vaginal birthA study protocol of vaginal dilator usage to know the efficacy based on labor outcomes.
期刊介绍:
IJS Protocols is the first peer-reviewed, international, open access journal seeking to publish research protocols across across the full breadth of the surgical field. We are aim to provide rapid submission to decision times whilst maintaining a high quality peer-review process.