高空视神经鞘直径:健康志愿者的标准化测量。

IF 3.4 Q2 Medicine Ultrasound Journal Pub Date : 2022-11-19 DOI:10.1186/s13089-022-00295-1
Edith Elianna Rodríguez Aparicio, Jorge Armando Carrizosa Gonzalez, David Rene Rodriguez Lima
{"title":"高空视神经鞘直径:健康志愿者的标准化测量。","authors":"Edith Elianna Rodríguez Aparicio,&nbsp;Jorge Armando Carrizosa Gonzalez,&nbsp;David Rene Rodriguez Lima","doi":"10.1186/s13089-022-00295-1","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Increases in the diameter of the optic nerve sheath (ONSD) on ultrasound are associated with high intracranial pressure (hICP). The normal value varies with altitude and the population studied. The objective of this study is to describe the normal values of the ONSD in a healthy adult population of the city of Bogotá, Colombia, at 2640 meters above sea level (masl).</p><p><strong>Patients and methods: </strong>A prospective observational study was conducted on a total of 247 healthy individuals recruited from May 2021 to May 2022 who were subjected to the color, low power, optic disk, safety, elevated frequency, dual (CLOSED) protocol for measuring the bilateral ONSD adjusted to the eyeball transverse diameter (ETD).</p><p><strong>Results: </strong>A total of 230 individuals were analyzed; the average ONSD of the right eye (RE) was 0.449 cm (range 0.288-0.7) and that of the left eye (LE) was 0.454 cm (range 0.285-0.698); the correlation between RE and LE was 0.93 (p < 0.005), and the correlation of the ONSD/ETD ratios for the RE and LE was lower (r<sup>2</sup> = 0.79, p < 0.005). A total of 10.8% of the studied population had values greater than 0.55 cm.</p><p><strong>Conclusions: </strong>The median ONSD and ONSD/ETD ratio in the city of Bogotá are similar to those described in other populations; however, approximately 10.8% of the healthy population may present higher values, which would limit the use of ONSD on its own for clinical decision-making, only repeated measurements with significant changes in the ONSD and ONSD/ETD or asymmetries between the measurements of both eyes linked to clinical findings would allow the diagnosis of hICP.</p>","PeriodicalId":36911,"journal":{"name":"Ultrasound Journal","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2022-11-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674817/pdf/","citationCount":"1","resultStr":"{\"title\":\"Optic nerve sheath diameter at high altitude: standardized measures in healthy volunteers.\",\"authors\":\"Edith Elianna Rodríguez Aparicio,&nbsp;Jorge Armando Carrizosa Gonzalez,&nbsp;David Rene Rodriguez Lima\",\"doi\":\"10.1186/s13089-022-00295-1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Increases in the diameter of the optic nerve sheath (ONSD) on ultrasound are associated with high intracranial pressure (hICP). The normal value varies with altitude and the population studied. The objective of this study is to describe the normal values of the ONSD in a healthy adult population of the city of Bogotá, Colombia, at 2640 meters above sea level (masl).</p><p><strong>Patients and methods: </strong>A prospective observational study was conducted on a total of 247 healthy individuals recruited from May 2021 to May 2022 who were subjected to the color, low power, optic disk, safety, elevated frequency, dual (CLOSED) protocol for measuring the bilateral ONSD adjusted to the eyeball transverse diameter (ETD).</p><p><strong>Results: </strong>A total of 230 individuals were analyzed; the average ONSD of the right eye (RE) was 0.449 cm (range 0.288-0.7) and that of the left eye (LE) was 0.454 cm (range 0.285-0.698); the correlation between RE and LE was 0.93 (p < 0.005), and the correlation of the ONSD/ETD ratios for the RE and LE was lower (r<sup>2</sup> = 0.79, p < 0.005). A total of 10.8% of the studied population had values greater than 0.55 cm.</p><p><strong>Conclusions: </strong>The median ONSD and ONSD/ETD ratio in the city of Bogotá are similar to those described in other populations; however, approximately 10.8% of the healthy population may present higher values, which would limit the use of ONSD on its own for clinical decision-making, only repeated measurements with significant changes in the ONSD and ONSD/ETD or asymmetries between the measurements of both eyes linked to clinical findings would allow the diagnosis of hICP.</p>\",\"PeriodicalId\":36911,\"journal\":{\"name\":\"Ultrasound Journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2022-11-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9674817/pdf/\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s13089-022-00295-1\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13089-022-00295-1","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 1

摘要

背景:超声显示视神经鞘(ONSD)直径增加与高颅内压(hICP)有关。正常值随海拔和所研究的人群而变化。本研究的目的是描述哥伦比亚波哥大市海拔2640米的健康成年人口的ONSD正常值(masl)。患者和方法:本研究于2021年5月至2022年5月招募247名健康受试者,采用彩色、低功率、视盘、安全、高频率、双(CLOSED)方案测量调整至眼球横径(ETD)的双侧ONSD。结果:共分析了230例个体;右眼(RE)平均ONSD为0.449 cm(范围0.288 ~ 0.7),左眼(LE)平均ONSD为0.454 cm(范围0.285 ~ 0.698);RE和LE的相关性为0.93 (p 2 = 0.79, p)。结论:波哥大市的ONSD中位数和ONSD/ETD比值与其他人群相似;然而,大约10.8%的健康人群可能会出现更高的值,这将限制ONSD单独用于临床决策,只有反复测量ONSD和ONSD/ETD的显著变化或双眼测量与临床表现相关的不对称才能诊断hICP。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Optic nerve sheath diameter at high altitude: standardized measures in healthy volunteers.

Background: Increases in the diameter of the optic nerve sheath (ONSD) on ultrasound are associated with high intracranial pressure (hICP). The normal value varies with altitude and the population studied. The objective of this study is to describe the normal values of the ONSD in a healthy adult population of the city of Bogotá, Colombia, at 2640 meters above sea level (masl).

Patients and methods: A prospective observational study was conducted on a total of 247 healthy individuals recruited from May 2021 to May 2022 who were subjected to the color, low power, optic disk, safety, elevated frequency, dual (CLOSED) protocol for measuring the bilateral ONSD adjusted to the eyeball transverse diameter (ETD).

Results: A total of 230 individuals were analyzed; the average ONSD of the right eye (RE) was 0.449 cm (range 0.288-0.7) and that of the left eye (LE) was 0.454 cm (range 0.285-0.698); the correlation between RE and LE was 0.93 (p < 0.005), and the correlation of the ONSD/ETD ratios for the RE and LE was lower (r2 = 0.79, p < 0.005). A total of 10.8% of the studied population had values greater than 0.55 cm.

Conclusions: The median ONSD and ONSD/ETD ratio in the city of Bogotá are similar to those described in other populations; however, approximately 10.8% of the healthy population may present higher values, which would limit the use of ONSD on its own for clinical decision-making, only repeated measurements with significant changes in the ONSD and ONSD/ETD or asymmetries between the measurements of both eyes linked to clinical findings would allow the diagnosis of hICP.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasound Journal
Ultrasound Journal Health Professions-Radiological and Ultrasound Technology
CiteScore
6.80
自引率
2.90%
发文量
45
审稿时长
22 weeks
期刊最新文献
Quantitative lung ultrasound findings correlate with radial alveolar count in experimental bronchopulmonary dysplasia. Tele-education in point-of-care ultrasound training. Comparison of 6 handheld ultrasound devices by point-of-care ultrasound experts: a cross-sectional study. Student ultrasound education, current view and controversies. Role of Artificial Intelligence, Virtual Reality and telemedicine. Sonographic findings using the SAFE-A protocol in pre- and post-hemodialysis patients.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1