有针对性的代谢分析尿类固醇与重点分析的准确性和样品的稳定性

IF 3.1 4区 医学 Q2 MEDICAL LABORATORY TECHNOLOGY Journal of Mass Spectrometry and Advances in the Clinical Lab Pub Date : 2022-08-01 DOI:10.1016/j.jmsacl.2022.07.006
Nora Vogg , Tobias Müller , Andreas Floren , Thomas Dandekar , Oliver Scherf-Clavel , Martin Fassnacht , Matthias Kroiss , Max Kurlbaum
{"title":"有针对性的代谢分析尿类固醇与重点分析的准确性和样品的稳定性","authors":"Nora Vogg ,&nbsp;Tobias Müller ,&nbsp;Andreas Floren ,&nbsp;Thomas Dandekar ,&nbsp;Oliver Scherf-Clavel ,&nbsp;Martin Fassnacht ,&nbsp;Matthias Kroiss ,&nbsp;Max Kurlbaum","doi":"10.1016/j.jmsacl.2022.07.006","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><p>Preoperative diagnostic workup of adrenal tumors is based on imaging and hormone analyses, but charged with uncertainties. Steroid profiling by liquid chromatography tandem mass spectrometry (LC-MS/MS) in 24-h urine has shown potential to discriminate benign and malignant adrenal tumors. Our aim was to develop and validate a specific and accurate LC-MS/MS method for the quantification of deconjugated urinary marker steroids, to evaluate their pre-analytical stability and to apply the method to clinical samples of patients with adrenal tumors.</p></div><div><h3>Methods</h3><p>A method for the quantification of 11 deconjugated steroids (5-pregnenetriol, dehydroepiandrosterone, cortisone, cortisol, α-cortolone, tetrahydro-11-deoxycortisol, etiocholanolone, pregnenolone, pregnanetriol, pregnanediol, and 5-pregnenediol) in human urine was developed and validated based on international guidelines. Steroids were enzymatically deconjugated and extracted by solid phase extraction before LC-MS/MS quantification in positive electrospray ionization mode.</p></div><div><h3>Results</h3><p>Excellent linearity with R<sup>2</sup> &gt; 0.99 and intra- and inter-day precisions of &lt; 10.1 % were found. Relative matrix effects were between 96.4 % and 101.6 % and relative recovery was between 98.2 % and 115.0 %. Sufficient pre-freeze stability for all steroids in urine was found at 20–25 °C for seven days and at 4–6 °C for up to 28 days. Samples were stable during long-term storage at −20 °C and −80 °C for 6 months.</p></div><div><h3>Conclusions</h3><p>A sensitive and robust LC-MS/MS method for the quantification of 11 urinary steroids was developed and validated according to international guidelines. Pre-analytical matrix stability was evaluated and the suitability of the method for the analysis of clinical samples and prospective validation studies was shown.</p></div>","PeriodicalId":52406,"journal":{"name":"Journal of Mass Spectrometry and Advances in the Clinical Lab","volume":"25 ","pages":"Pages 44-52"},"PeriodicalIF":3.1000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/33/df/main.PMC9334310.pdf","citationCount":"3","resultStr":"{\"title\":\"Targeted metabolic profiling of urinary steroids with a focus on analytical accuracy and sample stability\",\"authors\":\"Nora Vogg ,&nbsp;Tobias Müller ,&nbsp;Andreas Floren ,&nbsp;Thomas Dandekar ,&nbsp;Oliver Scherf-Clavel ,&nbsp;Martin Fassnacht ,&nbsp;Matthias Kroiss ,&nbsp;Max Kurlbaum\",\"doi\":\"10.1016/j.jmsacl.2022.07.006\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><h3>Introduction</h3><p>Preoperative diagnostic workup of adrenal tumors is based on imaging and hormone analyses, but charged with uncertainties. Steroid profiling by liquid chromatography tandem mass spectrometry (LC-MS/MS) in 24-h urine has shown potential to discriminate benign and malignant adrenal tumors. Our aim was to develop and validate a specific and accurate LC-MS/MS method for the quantification of deconjugated urinary marker steroids, to evaluate their pre-analytical stability and to apply the method to clinical samples of patients with adrenal tumors.</p></div><div><h3>Methods</h3><p>A method for the quantification of 11 deconjugated steroids (5-pregnenetriol, dehydroepiandrosterone, cortisone, cortisol, α-cortolone, tetrahydro-11-deoxycortisol, etiocholanolone, pregnenolone, pregnanetriol, pregnanediol, and 5-pregnenediol) in human urine was developed and validated based on international guidelines. Steroids were enzymatically deconjugated and extracted by solid phase extraction before LC-MS/MS quantification in positive electrospray ionization mode.</p></div><div><h3>Results</h3><p>Excellent linearity with R<sup>2</sup> &gt; 0.99 and intra- and inter-day precisions of &lt; 10.1 % were found. Relative matrix effects were between 96.4 % and 101.6 % and relative recovery was between 98.2 % and 115.0 %. Sufficient pre-freeze stability for all steroids in urine was found at 20–25 °C for seven days and at 4–6 °C for up to 28 days. Samples were stable during long-term storage at −20 °C and −80 °C for 6 months.</p></div><div><h3>Conclusions</h3><p>A sensitive and robust LC-MS/MS method for the quantification of 11 urinary steroids was developed and validated according to international guidelines. Pre-analytical matrix stability was evaluated and the suitability of the method for the analysis of clinical samples and prospective validation studies was shown.</p></div>\",\"PeriodicalId\":52406,\"journal\":{\"name\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"volume\":\"25 \",\"pages\":\"Pages 44-52\"},\"PeriodicalIF\":3.1000,\"publicationDate\":\"2022-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/33/df/main.PMC9334310.pdf\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Mass Spectrometry and Advances in the Clinical Lab\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S2667145X22000244\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"MEDICAL LABORATORY TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Mass Spectrometry and Advances in the Clinical Lab","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2667145X22000244","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICAL LABORATORY TECHNOLOGY","Score":null,"Total":0}
引用次数: 3

摘要

肾上腺肿瘤的术前诊断是基于影像学和激素分析,但充满了不确定性。采用液相色谱串联质谱法(LC-MS/MS)对24小时尿液进行类固醇谱分析已显示出鉴别肾上腺良性和恶性肿瘤的潜力。我们的目的是开发和验证一种特异性和准确的LC-MS/MS方法,用于定量解偶联尿液标记类固醇,评估其分析前稳定性,并将该方法应用于肾上腺肿瘤患者的临床样本。方法根据国际标准,建立测定人尿中11种去缀合类固醇(5-孕烯三醇、脱氢表雄酮、可的松、皮质醇、α-cortolone、四氢-11-脱氧皮质醇、依地胆醇酮、孕烯醇酮、孕烯三醇、孕二醇和5-孕烯二醇)含量的方法。在LC-MS/MS正电喷雾模式下定量前,酶解甾体并进行固相萃取。结果与R2 >线性良好;0.99和<的日内和日间精度;10.1%被发现。相对基质效应为96.4% ~ 101.6%,相对回收率为98.2% ~ 115.0%。在20-25°C和4-6°C条件下,所有尿液中的类固醇均具有足够的冷冻前稳定性,可保存7天,最长可保存28天。样品在- 20°C和- 80°C条件下长期保存6个月稳定。结论建立了一种灵敏、可靠的LC-MS/MS定量方法,并根据国际标准进行了验证。对分析前基质稳定性进行了评估,并证明了该方法用于临床样品分析和前瞻性验证研究的适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Targeted metabolic profiling of urinary steroids with a focus on analytical accuracy and sample stability

Introduction

Preoperative diagnostic workup of adrenal tumors is based on imaging and hormone analyses, but charged with uncertainties. Steroid profiling by liquid chromatography tandem mass spectrometry (LC-MS/MS) in 24-h urine has shown potential to discriminate benign and malignant adrenal tumors. Our aim was to develop and validate a specific and accurate LC-MS/MS method for the quantification of deconjugated urinary marker steroids, to evaluate their pre-analytical stability and to apply the method to clinical samples of patients with adrenal tumors.

Methods

A method for the quantification of 11 deconjugated steroids (5-pregnenetriol, dehydroepiandrosterone, cortisone, cortisol, α-cortolone, tetrahydro-11-deoxycortisol, etiocholanolone, pregnenolone, pregnanetriol, pregnanediol, and 5-pregnenediol) in human urine was developed and validated based on international guidelines. Steroids were enzymatically deconjugated and extracted by solid phase extraction before LC-MS/MS quantification in positive electrospray ionization mode.

Results

Excellent linearity with R2 > 0.99 and intra- and inter-day precisions of < 10.1 % were found. Relative matrix effects were between 96.4 % and 101.6 % and relative recovery was between 98.2 % and 115.0 %. Sufficient pre-freeze stability for all steroids in urine was found at 20–25 °C for seven days and at 4–6 °C for up to 28 days. Samples were stable during long-term storage at −20 °C and −80 °C for 6 months.

Conclusions

A sensitive and robust LC-MS/MS method for the quantification of 11 urinary steroids was developed and validated according to international guidelines. Pre-analytical matrix stability was evaluated and the suitability of the method for the analysis of clinical samples and prospective validation studies was shown.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Mass Spectrometry and Advances in the Clinical Lab
Journal of Mass Spectrometry and Advances in the Clinical Lab Health Professions-Medical Laboratory Technology
CiteScore
4.30
自引率
18.20%
发文量
41
审稿时长
81 days
期刊最新文献
Tandem mass spectrometry of serum cholestanoic (C27) acids – Typical concentration ranges and application to the study of peroxisomal biogenesis disorders Research letter: Pilot study of a prototype fully automated mass spectrometry system for routine clinical laboratory use Method validation of an inductively coupled plasma mass spectrometry (ICP-MS) assay for the analysis of magnesium, copper and zinc in red blood cells Liquid chromatography-mass spectrometric method for the simultaneous analysis of branched-chain amino acids and their ketoacids from dried blood spot as secondary analytes for the detection of maple syrup urine disease Development and validation of an LC-MS/MS method for highly concentrated tacrolimus and cyclosporine samples prepared from pharmaceutical products to assess drug loss from feeding tubes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1