James Cashin, Patrick Flynn, Judith Worthington, Marcus Lowe, Andrew Canterbury, Kristin Launhardt, Ian Crosby, Stephen Sheldon, Rajamiyer Venkateswaran, Kay Poulton
{"title":"HISTO SPOT®AB ID I类和II类检测在心胸移植患者中的早期评估","authors":"James Cashin, Patrick Flynn, Judith Worthington, Marcus Lowe, Andrew Canterbury, Kristin Launhardt, Ian Crosby, Stephen Sheldon, Rajamiyer Venkateswaran, Kay Poulton","doi":"10.1111/iji.12595","DOIUrl":null,"url":null,"abstract":"<p>The HISTO SPOT<sup>®</sup>AB ID assay (BAG Diagnostics GmbH) is a novel single antigen HLA Class I & II antibody definition test used with the MR.SPOT<sup>®</sup> processor. We compared this assay with Luminex<sup>®</sup>-based assays to assess its potential application in defining unacceptable antigens for transplantation in patients awaiting transplants with cardiothoracic organs. A cohort of 40 sensitized cardiothoracic patients were identified, and one sample was selected from each patient. The required screening was based on the patients’ antibody profiles (Class I, <i>n</i> = 17, Class II, <i>n</i> = 11, Class I & II, <i>n</i> = 12). Samples were screened with LABScreen™ Single Antigen (SAg), LIFECODES<sup>®</sup> LSA™, HISTO SPOT<sup>®</sup> AB ID, and an acid modified LABScreen™ SAg test for detecting antibodies against denatured HLA. Results indicated that HISTO SPOT<sup>®</sup> AB ID had reduced sensitivity (68% for Class I; 69% for Class II). When compared to LABScreen™ and LIFECODES<sup>®</sup>, HISTO SPOT<sup>®</sup> AB ID failed to detect Luminex<sup>®</sup>-defined antibodies with median fluorescence intensity (MFI) ranging from 1114 to 24,489. The HISTO SPOT<sup>®</sup> AB ID panel used in the study had reduced antigen representation compared with Luminex<sup>®</sup>-based assays which further compromised its capacity for antibody detection and definition. Further work is needed to evaluate the clinical relevance of these differences between the performance of HISTO SPOT<sup>®</sup> and Luminex<sup>®</sup>-based methods.</p>","PeriodicalId":14003,"journal":{"name":"International Journal of Immunogenetics","volume":"49 5","pages":"317-324"},"PeriodicalIF":2.3000,"publicationDate":"2022-08-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"An early evaluation of the HISTO SPOT® AB ID Class I & II test in cardiothoracic transplant patients\",\"authors\":\"James Cashin, Patrick Flynn, Judith Worthington, Marcus Lowe, Andrew Canterbury, Kristin Launhardt, Ian Crosby, Stephen Sheldon, Rajamiyer Venkateswaran, Kay Poulton\",\"doi\":\"10.1111/iji.12595\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>The HISTO SPOT<sup>®</sup>AB ID assay (BAG Diagnostics GmbH) is a novel single antigen HLA Class I & II antibody definition test used with the MR.SPOT<sup>®</sup> processor. We compared this assay with Luminex<sup>®</sup>-based assays to assess its potential application in defining unacceptable antigens for transplantation in patients awaiting transplants with cardiothoracic organs. A cohort of 40 sensitized cardiothoracic patients were identified, and one sample was selected from each patient. The required screening was based on the patients’ antibody profiles (Class I, <i>n</i> = 17, Class II, <i>n</i> = 11, Class I & II, <i>n</i> = 12). Samples were screened with LABScreen™ Single Antigen (SAg), LIFECODES<sup>®</sup> LSA™, HISTO SPOT<sup>®</sup> AB ID, and an acid modified LABScreen™ SAg test for detecting antibodies against denatured HLA. Results indicated that HISTO SPOT<sup>®</sup> AB ID had reduced sensitivity (68% for Class I; 69% for Class II). When compared to LABScreen™ and LIFECODES<sup>®</sup>, HISTO SPOT<sup>®</sup> AB ID failed to detect Luminex<sup>®</sup>-defined antibodies with median fluorescence intensity (MFI) ranging from 1114 to 24,489. The HISTO SPOT<sup>®</sup> AB ID panel used in the study had reduced antigen representation compared with Luminex<sup>®</sup>-based assays which further compromised its capacity for antibody detection and definition. Further work is needed to evaluate the clinical relevance of these differences between the performance of HISTO SPOT<sup>®</sup> and Luminex<sup>®</sup>-based methods.</p>\",\"PeriodicalId\":14003,\"journal\":{\"name\":\"International Journal of Immunogenetics\",\"volume\":\"49 5\",\"pages\":\"317-324\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2022-08-21\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Immunogenetics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1111/iji.12595\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"GENETICS & HEREDITY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Immunogenetics","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1111/iji.12595","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GENETICS & HEREDITY","Score":null,"Total":0}
An early evaluation of the HISTO SPOT® AB ID Class I & II test in cardiothoracic transplant patients
The HISTO SPOT®AB ID assay (BAG Diagnostics GmbH) is a novel single antigen HLA Class I & II antibody definition test used with the MR.SPOT® processor. We compared this assay with Luminex®-based assays to assess its potential application in defining unacceptable antigens for transplantation in patients awaiting transplants with cardiothoracic organs. A cohort of 40 sensitized cardiothoracic patients were identified, and one sample was selected from each patient. The required screening was based on the patients’ antibody profiles (Class I, n = 17, Class II, n = 11, Class I & II, n = 12). Samples were screened with LABScreen™ Single Antigen (SAg), LIFECODES® LSA™, HISTO SPOT® AB ID, and an acid modified LABScreen™ SAg test for detecting antibodies against denatured HLA. Results indicated that HISTO SPOT® AB ID had reduced sensitivity (68% for Class I; 69% for Class II). When compared to LABScreen™ and LIFECODES®, HISTO SPOT® AB ID failed to detect Luminex®-defined antibodies with median fluorescence intensity (MFI) ranging from 1114 to 24,489. The HISTO SPOT® AB ID panel used in the study had reduced antigen representation compared with Luminex®-based assays which further compromised its capacity for antibody detection and definition. Further work is needed to evaluate the clinical relevance of these differences between the performance of HISTO SPOT® and Luminex®-based methods.
期刊介绍:
The International Journal of Immunogenetics (formerly European Journal of Immunogenetics) publishes original contributions on the genetic control of components of the immune system and their interactions in both humans and experimental animals. The term ''genetic'' is taken in its broadest sense to include studies at the evolutionary, molecular, chromosomal functional and population levels in both health and disease. Examples are:
-studies of blood groups and other surface antigens-
cell interactions and immune response-
receptors, antibodies, complement components and cytokines-
polymorphism-
evolution of the organisation, control and function of immune system components-
anthropology and disease associations-
the genetics of immune-related disease: allergy, autoimmunity, immunodeficiency and other immune pathologies-
All papers are seen by at least two independent referees and only papers of the highest quality are accepted.