碘-131治疗甲状腺功能亢进患者体重指数与外照射的关系

IF 2 Q3 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING American journal of nuclear medicine and molecular imaging Pub Date : 2022-06-15 eCollection Date: 2022-01-01
Ghazal Yazdanpanah, Mohammad Nematdar, Hoda Talebian, Ali Shabestani Monfared
{"title":"碘-131治疗甲状腺功能亢进患者体重指数与外照射的关系","authors":"Ghazal Yazdanpanah,&nbsp;Mohammad Nematdar,&nbsp;Hoda Talebian,&nbsp;Ali Shabestani Monfared","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We performed this study to evaluate the correlation between Body Mass Index (BMI) and Exposure Rate (ER) of hyperthyroid patients treated with iodine-131 so that in case of any relationship, we can improve the prescribed dose for the treatment of hyperthyroid patients and its side effects on the body and the environment. In this analytical and cross-sectional study, 30 patients with hyperthyroidism treated with liquid iodine-131 were randomly selected. We recorded demographic indicators (age, height, and weight) and ER. Patients were treated with the activity of 8-29 mCi (mean 14.4 mCi) oral I-131. The external radiation of patients was measured from a distance of one meter parallel to the patient's thyroid gland at intervals of 6 to 24 hours post-iodine-131 administration. ER measurements and other acquired data were statistically analyzed by R software and its methods. Data were normalized using the Shapiro method, and due to the non-normality of the data in the correlation test, the Spearman method was used. The measurements of this study represent two main findings: 1. There is a significant relationship between ER and iodine-131 activity because the observed significance level (<i>P</i>-value =0.002) is smaller than the predicted error value (0.01). 2. There is no significant relationship between ER and BMI because the observed significance level (<i>P</i>-value =0.082) is greater than the predicted error value (0.05). The present study's findings show a negative relationship between BMI and ER. Still, since the <i>P</i>-value is more than 0.05, this relationship is not statistically significant.</p>","PeriodicalId":7572,"journal":{"name":"American journal of nuclear medicine and molecular imaging","volume":null,"pages":null},"PeriodicalIF":2.0000,"publicationDate":"2022-06-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9301089/pdf/ajnmmi0012-0099.pdf","citationCount":"0","resultStr":"{\"title\":\"Relationship between body mass index and external exposure in hyperthyroid patients treated with iodine-131.\",\"authors\":\"Ghazal Yazdanpanah,&nbsp;Mohammad Nematdar,&nbsp;Hoda Talebian,&nbsp;Ali Shabestani Monfared\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We performed this study to evaluate the correlation between Body Mass Index (BMI) and Exposure Rate (ER) of hyperthyroid patients treated with iodine-131 so that in case of any relationship, we can improve the prescribed dose for the treatment of hyperthyroid patients and its side effects on the body and the environment. In this analytical and cross-sectional study, 30 patients with hyperthyroidism treated with liquid iodine-131 were randomly selected. We recorded demographic indicators (age, height, and weight) and ER. Patients were treated with the activity of 8-29 mCi (mean 14.4 mCi) oral I-131. The external radiation of patients was measured from a distance of one meter parallel to the patient's thyroid gland at intervals of 6 to 24 hours post-iodine-131 administration. ER measurements and other acquired data were statistically analyzed by R software and its methods. Data were normalized using the Shapiro method, and due to the non-normality of the data in the correlation test, the Spearman method was used. The measurements of this study represent two main findings: 1. There is a significant relationship between ER and iodine-131 activity because the observed significance level (<i>P</i>-value =0.002) is smaller than the predicted error value (0.01). 2. There is no significant relationship between ER and BMI because the observed significance level (<i>P</i>-value =0.082) is greater than the predicted error value (0.05). The present study's findings show a negative relationship between BMI and ER. Still, since the <i>P</i>-value is more than 0.05, this relationship is not statistically significant.</p>\",\"PeriodicalId\":7572,\"journal\":{\"name\":\"American journal of nuclear medicine and molecular imaging\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":2.0000,\"publicationDate\":\"2022-06-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9301089/pdf/ajnmmi0012-0099.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"American journal of nuclear medicine and molecular imaging\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"American journal of nuclear medicine and molecular imaging","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

本研究旨在探讨碘-131治疗甲状腺功能亢进患者的身体质量指数(BMI)与暴露率(ER)之间的相关性,以便在存在相关性的情况下,改善甲状腺功能亢进患者的处方剂量及其对身体和环境的副作用。在这项分析性和横断面研究中,随机选择30例用液体碘-131治疗的甲亢患者。我们记录了人口统计指标(年龄、身高和体重)和ER。患者接受8-29 mCi(平均14.4 mCi)口服I-131治疗。在碘-131给药后每隔6至24小时,从与患者甲状腺平行的1米距离处测量患者的外辐射。利用R软件及其方法对ER测量及其他采集数据进行统计分析。数据采用Shapiro方法归一化,由于相关检验中数据的非正态性,采用Spearman方法。本研究的测量结果有两个主要发现:1。ER与碘-131活性之间存在极显著的相关关系,因为观察到的显著性水平(p值=0.002)小于预测误差(0.01)。2. ER与BMI之间无显著相关,观察到的显著性水平(p值=0.082)大于预测误差(0.05)。目前的研究结果显示BMI和ER之间呈负相关。然而,由于p值大于0.05,因此这种关系在统计上不显著。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Relationship between body mass index and external exposure in hyperthyroid patients treated with iodine-131.

We performed this study to evaluate the correlation between Body Mass Index (BMI) and Exposure Rate (ER) of hyperthyroid patients treated with iodine-131 so that in case of any relationship, we can improve the prescribed dose for the treatment of hyperthyroid patients and its side effects on the body and the environment. In this analytical and cross-sectional study, 30 patients with hyperthyroidism treated with liquid iodine-131 were randomly selected. We recorded demographic indicators (age, height, and weight) and ER. Patients were treated with the activity of 8-29 mCi (mean 14.4 mCi) oral I-131. The external radiation of patients was measured from a distance of one meter parallel to the patient's thyroid gland at intervals of 6 to 24 hours post-iodine-131 administration. ER measurements and other acquired data were statistically analyzed by R software and its methods. Data were normalized using the Shapiro method, and due to the non-normality of the data in the correlation test, the Spearman method was used. The measurements of this study represent two main findings: 1. There is a significant relationship between ER and iodine-131 activity because the observed significance level (P-value =0.002) is smaller than the predicted error value (0.01). 2. There is no significant relationship between ER and BMI because the observed significance level (P-value =0.082) is greater than the predicted error value (0.05). The present study's findings show a negative relationship between BMI and ER. Still, since the P-value is more than 0.05, this relationship is not statistically significant.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
American journal of nuclear medicine and molecular imaging
American journal of nuclear medicine and molecular imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
自引率
4.00%
发文量
4
期刊介绍: The scope of AJNMMI encompasses all areas of molecular imaging, including but not limited to: positron emission tomography (PET), single-photon emission computed tomography (SPECT), molecular magnetic resonance imaging, magnetic resonance spectroscopy, optical bioluminescence, optical fluorescence, targeted ultrasound, photoacoustic imaging, etc. AJNMMI welcomes original and review articles on both clinical investigation and preclinical research. Occasionally, special topic issues, short communications, editorials, and invited perspectives will also be published. Manuscripts, including figures and tables, must be original and not under consideration by another journal.
期刊最新文献
A radioactive and fluorescent dual modality cysteine cathepsin-B activity-based probe for the detection and treatment evaluation in rheumatoid arthritis. Accurate brain pharmacokinetic parametric imaging using the blood input function extracted from the cavernous sinus. Analysis of bone single-photon emission CT/CT and diffusion-weighted MR imaging in medication-related osteonecrosis of the jaw: focusing on the correlation between standardized uptake values and apparent diffusion coefficient values. Hemodynamic characteristics of vertebrobasilar artery fenestration combined with vertebrobasilar dolichoectasia: a study based on magnetic resonance angiography. Radiomics-based model for prediction of TGF-β1 expression in head and neck squamous cell carcinoma.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1