{"title":"南非转诊中心植入式心律转复除颤器植入和随访二十年:资源有限环境下的趋势、适应症和长期结果","authors":"Philasande Mkoko,&nbsp;Kayla Solomon,&nbsp;Ashley Chin","doi":"10.1186/s42444-022-00070-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>More than two-thirds of cardiovascular deaths occur in low- and middle-income countries. Sudden cardiac deaths (SCD) from ventricular arrhythmias are an important cause of cardiovascular deaths. Implantable cardioverter defibrillators (ICD) are an important therapeutic strategy for detecting and terminating ventricular arrhythmias in patients at risk of SCD. The profile of patients treated with ICDs in South Africa is unknown. Further, with changing lines of evidence, the implantation trends are undetermined. The objectives of this study were to determine the profile of ICD recipients and implantation trends in a South African quaternary hospital.</p><p><strong>Methods: </strong>This was a retrospective review of all patients implanted with ICDs at Groote Schuur Hospital from 01 January 1998 to 31 December 2020. A standardised data collection form was used to collect baseline demographic data, information on clinical presentation and ICD follow-up data for the history of ICD shock therapies.</p><p><strong>Results: </strong>A total of 253 ICDs were implanted; 75% for secondary prevention and 25% for primary prevention. 67.2% of the implanted ICDs were single-chamber ICDs, dual-chamber ICDs were implanted in 12.3% and Cardiac resynchronisation with a defibrillator (CRT-D) in 20.6%. There was an upward trajectory of ICD implantations during the study period. Increasing numbers of dual-chamber devices and CRT-D were implanted over time. ICD recipients had a mean (standard deviation) age of 50 (14) years and were predominantly male (69%). Primary prevention ICD recipients were younger than secondary prevention recipients, with a mean (SD) age of 46 (14) years versus 51 (14) years, <i>p</i> = 0.019. The secondary prevention group presented with ventricular tachycardia in 81%, ventricular fibrillation in 13% and cardiopulmonary resuscitation without documented heart rhythm in 5.3% (10/190). After a median (interquartile range) follow-up of 44 (15; 93) months, there was an overall mortality rate of 16.2%, with no mortality difference between the primary and secondary prevention patient groups.</p><p><strong>Conclusion: </strong>There is an increase in the annual number of ICDs implanted at a South African referral centre. ICDs are predominantly implanted for secondary prevention. However, over time the number of devices implanted for primary prevention is steadily increased. During follow-up, there was no mortality difference between the primary prevention and the secondary prevention groups.</p>","PeriodicalId":34172,"journal":{"name":"International Journal of Arrhythmia","volume":" ","pages":"19"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9340675/pdf/","citationCount":"0","resultStr":"{\"title\":\"Two decades of implantable cardioverter defibrillator implantation and follow-up at a South African referral centre: trends, indications and long-term outcomes in a resource-limited setting.\",\"authors\":\"Philasande Mkoko,&nbsp;Kayla Solomon,&nbsp;Ashley Chin\",\"doi\":\"10.1186/s42444-022-00070-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>More than two-thirds of cardiovascular deaths occur in low- and middle-income countries. Sudden cardiac deaths (SCD) from ventricular arrhythmias are an important cause of cardiovascular deaths. Implantable cardioverter defibrillators (ICD) are an important therapeutic strategy for detecting and terminating ventricular arrhythmias in patients at risk of SCD. The profile of patients treated with ICDs in South Africa is unknown. Further, with changing lines of evidence, the implantation trends are undetermined. The objectives of this study were to determine the profile of ICD recipients and implantation trends in a South African quaternary hospital.</p><p><strong>Methods: </strong>This was a retrospective review of all patients implanted with ICDs at Groote Schuur Hospital from 01 January 1998 to 31 December 2020. A standardised data collection form was used to collect baseline demographic data, information on clinical presentation and ICD follow-up data for the history of ICD shock therapies.</p><p><strong>Results: </strong>A total of 253 ICDs were implanted; 75% for secondary prevention and 25% for primary prevention. 67.2% of the implanted ICDs were single-chamber ICDs, dual-chamber ICDs were implanted in 12.3% and Cardiac resynchronisation with a defibrillator (CRT-D) in 20.6%. There was an upward trajectory of ICD implantations during the study period. Increasing numbers of dual-chamber devices and CRT-D were implanted over time. ICD recipients had a mean (standard deviation) age of 50 (14) years and were predominantly male (69%). Primary prevention ICD recipients were younger than secondary prevention recipients, with a mean (SD) age of 46 (14) years versus 51 (14) years, <i>p</i> = 0.019. The secondary prevention group presented with ventricular tachycardia in 81%, ventricular fibrillation in 13% and cardiopulmonary resuscitation without documented heart rhythm in 5.3% (10/190). After a median (interquartile range) follow-up of 44 (15; 93) months, there was an overall mortality rate of 16.2%, with no mortality difference between the primary and secondary prevention patient groups.</p><p><strong>Conclusion: </strong>There is an increase in the annual number of ICDs implanted at a South African referral centre. ICDs are predominantly implanted for secondary prevention. However, over time the number of devices implanted for primary prevention is steadily increased. During follow-up, there was no mortality difference between the primary prevention and the secondary prevention groups.</p>\",\"PeriodicalId\":34172,\"journal\":{\"name\":\"International Journal of Arrhythmia\",\"volume\":\" \",\"pages\":\"19\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9340675/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Arrhythmia\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s42444-022-00070-2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2022/8/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Arrhythmia","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s42444-022-00070-2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2022/8/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:三分之二以上的心血管死亡发生在低收入和中等收入国家。室性心律失常引起的心源性猝死(SCD)是心血管死亡的重要原因。植入式心律转复除颤器(ICD)是检测和终止SCD危险患者室性心律失常的重要治疗策略。南非接受icd治疗的患者情况尚不清楚。此外,随着证据的变化,植入趋势尚不确定。本研究的目的是确定ICD受者的概况和植入趋势在南非第四医院。方法:回顾性分析1998年1月1日至2020年12月31日在Groote Schuur医院植入icd的所有患者。采用标准化数据收集表收集基线人口统计数据、临床表现信息和ICD休克治疗史的ICD随访数据。结果:共植入icd 253个;75%用于二级预防,25%用于一级预防。67.2%为单腔icd, 12.3%为双腔icd, 20.6%为心脏再同步除颤器(CRT-D)。在研究期间,ICD植入率呈上升趋势。随着时间的推移,越来越多的双腔装置和CRT-D被植入。ICD受者的平均(标准差)年龄为50(14)岁,主要为男性(69%)。一级预防ICD受者比二级预防受者年轻,平均(SD)年龄分别为46(14)岁和51(14)岁,p = 0.019。二级预防组出现室性心动过速81%,室性颤动13%,无心律记录的心肺复苏5.3%(10/190)。中位(四分位数范围)随访44 (15;93)个月时,总死亡率为16.2%,一级预防组和二级预防组之间死亡率无差异。结论:每年在南非转诊中心植入icd的数量有所增加。植入式除颤器主要用于二级预防。然而,随着时间的推移,用于初级预防的装置植入数量稳步增加。在随访期间,一级预防组和二级预防组之间没有死亡率差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Two decades of implantable cardioverter defibrillator implantation and follow-up at a South African referral centre: trends, indications and long-term outcomes in a resource-limited setting.

Background: More than two-thirds of cardiovascular deaths occur in low- and middle-income countries. Sudden cardiac deaths (SCD) from ventricular arrhythmias are an important cause of cardiovascular deaths. Implantable cardioverter defibrillators (ICD) are an important therapeutic strategy for detecting and terminating ventricular arrhythmias in patients at risk of SCD. The profile of patients treated with ICDs in South Africa is unknown. Further, with changing lines of evidence, the implantation trends are undetermined. The objectives of this study were to determine the profile of ICD recipients and implantation trends in a South African quaternary hospital.

Methods: This was a retrospective review of all patients implanted with ICDs at Groote Schuur Hospital from 01 January 1998 to 31 December 2020. A standardised data collection form was used to collect baseline demographic data, information on clinical presentation and ICD follow-up data for the history of ICD shock therapies.

Results: A total of 253 ICDs were implanted; 75% for secondary prevention and 25% for primary prevention. 67.2% of the implanted ICDs were single-chamber ICDs, dual-chamber ICDs were implanted in 12.3% and Cardiac resynchronisation with a defibrillator (CRT-D) in 20.6%. There was an upward trajectory of ICD implantations during the study period. Increasing numbers of dual-chamber devices and CRT-D were implanted over time. ICD recipients had a mean (standard deviation) age of 50 (14) years and were predominantly male (69%). Primary prevention ICD recipients were younger than secondary prevention recipients, with a mean (SD) age of 46 (14) years versus 51 (14) years, p = 0.019. The secondary prevention group presented with ventricular tachycardia in 81%, ventricular fibrillation in 13% and cardiopulmonary resuscitation without documented heart rhythm in 5.3% (10/190). After a median (interquartile range) follow-up of 44 (15; 93) months, there was an overall mortality rate of 16.2%, with no mortality difference between the primary and secondary prevention patient groups.

Conclusion: There is an increase in the annual number of ICDs implanted at a South African referral centre. ICDs are predominantly implanted for secondary prevention. However, over time the number of devices implanted for primary prevention is steadily increased. During follow-up, there was no mortality difference between the primary prevention and the secondary prevention groups.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
27
审稿时长
31 weeks
期刊最新文献
Atrial fibrillation fact sheet in Korea 2024 (part 3): treatment for atrial fibrillation in Korea: medicines and ablation Clinical role of genetic testing for the Brugada syndrome overlapping with arrhythmogenic cardiomyopathy Atrial fibrillation fact sheet in Korea 2024 (part 1): epidemiology of atrial fibrillation in Korea The unexpected complications of the left bundle branch area pacing (LBBAP) maneuver: a case report Cardiac repolarization abnormalities and neurally mediated syncope: overlooked aspects in the diagnosis of pheochromocytoma
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1