{"title":"全球纵向应变检测地中海贫血患者心脏铁超载:一项具有个体水平参与者数据的观察性研究的荟萃分析。","authors":"Armin Attar, Alireza Hosseinpour, Hamidreza Hosseinpour, Nahid Rezaeian, Firoozeh Abtahi, Fereshte Mehdizadeh, Mozhgan Parsaee, Nehzat Akiash, Mohaddeseh Behjati, Antonella Meloni, Alessia Pepe","doi":"10.1186/s12947-022-00291-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Although cardiac magnetic resonance (CMR) is the most reliable tool for assessment of CIO in patients with thalassemia, it is not always readily available. Recent studies have explored the potential of GLS as an alternative for diagnosis of CIO. We aimed to investigate the efficacy of global longitudinal strain (GLS) for detection of cardiac iron level (CIO).</p><p><strong>Methods: </strong>We searched SCOPUS, MEDLINE, and Embase to identify the studies which used GLS for assessment of CIO. We searched for individual participant data (IPD) in eligible studies to perform ROC curve analysis. CMR with a T2* cut-off value of 20 ms was considered as the gold standard. A meta-analysis was performed and the risk of bias was assessed using the JBI Checklist.</p><p><strong>Results: </strong>A total of 14 studies with 789 thalassemia patients (310 and 430 with and without CIO respectively and 49 with undetermined condition) were considered eligible for meta-analysis. IPDs of 405 participants were available. GLS was significantly lower in patients with CIO (-17.5 ± 2.7%) compared to those without CIO (-19.9 ± 2.3%; WMD = 1.6%, 95% CI = [0.76-2.4], p = 0.001, I<sup>2</sup> = 77.1%) and to normal population (-20.61 ± 2.26%; WMD = 2.2%, 95% CI = [0.91-3.5], p = 0.001, I<sup>2</sup> = 83.9%). A GLS < -19.5% could predict CIO with 92.8% sensitivity and 34.63% specificity (AUC = 0.659, 95% CI = [0.6-0.72], p-value < 0.0001). A GLS value < -6% has 100% positive predictive and ≥ -24.5% has 100% negative predictive values for detection of CIO.</p><p><strong>Conclusions: </strong>According to our study, GLS is a strong predictor of CIO and when CMR is not available, it may be a useful screening method for identification of CIO in thalassemia patients.</p>","PeriodicalId":9613,"journal":{"name":"Cardiovascular Ultrasound","volume":" ","pages":"22"},"PeriodicalIF":1.9000,"publicationDate":"2022-08-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9373500/pdf/","citationCount":"2","resultStr":"{\"title\":\"Global longitudinal strain for detection of cardiac iron overload in patients with thalassemia: a meta-analysis of observational studies with individual-level participant data.\",\"authors\":\"Armin Attar, Alireza Hosseinpour, Hamidreza Hosseinpour, Nahid Rezaeian, Firoozeh Abtahi, Fereshte Mehdizadeh, Mozhgan Parsaee, Nehzat Akiash, Mohaddeseh Behjati, Antonella Meloni, Alessia Pepe\",\"doi\":\"10.1186/s12947-022-00291-4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Although cardiac magnetic resonance (CMR) is the most reliable tool for assessment of CIO in patients with thalassemia, it is not always readily available. Recent studies have explored the potential of GLS as an alternative for diagnosis of CIO. We aimed to investigate the efficacy of global longitudinal strain (GLS) for detection of cardiac iron level (CIO).</p><p><strong>Methods: </strong>We searched SCOPUS, MEDLINE, and Embase to identify the studies which used GLS for assessment of CIO. We searched for individual participant data (IPD) in eligible studies to perform ROC curve analysis. CMR with a T2* cut-off value of 20 ms was considered as the gold standard. A meta-analysis was performed and the risk of bias was assessed using the JBI Checklist.</p><p><strong>Results: </strong>A total of 14 studies with 789 thalassemia patients (310 and 430 with and without CIO respectively and 49 with undetermined condition) were considered eligible for meta-analysis. IPDs of 405 participants were available. GLS was significantly lower in patients with CIO (-17.5 ± 2.7%) compared to those without CIO (-19.9 ± 2.3%; WMD = 1.6%, 95% CI = [0.76-2.4], p = 0.001, I<sup>2</sup> = 77.1%) and to normal population (-20.61 ± 2.26%; WMD = 2.2%, 95% CI = [0.91-3.5], p = 0.001, I<sup>2</sup> = 83.9%). A GLS < -19.5% could predict CIO with 92.8% sensitivity and 34.63% specificity (AUC = 0.659, 95% CI = [0.6-0.72], p-value < 0.0001). A GLS value < -6% has 100% positive predictive and ≥ -24.5% has 100% negative predictive values for detection of CIO.</p><p><strong>Conclusions: </strong>According to our study, GLS is a strong predictor of CIO and when CMR is not available, it may be a useful screening method for identification of CIO in thalassemia patients.</p>\",\"PeriodicalId\":9613,\"journal\":{\"name\":\"Cardiovascular Ultrasound\",\"volume\":\" \",\"pages\":\"22\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2022-08-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC9373500/pdf/\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Cardiovascular Ultrasound\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1186/s12947-022-00291-4\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"CARDIAC & CARDIOVASCULAR SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiovascular Ultrasound","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12947-022-00291-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 2
摘要
背景:虽然心脏磁共振(CMR)是评估地中海贫血患者CIO最可靠的工具,但它并不总是现成的。最近的研究已经探索了GLS作为诊断CIO的替代方法的潜力。我们的目的是探讨全局纵向应变(GLS)检测心脏铁水平(CIO)的有效性。方法:检索SCOPUS、MEDLINE和Embase,找出使用GLS评估CIO的研究。我们在符合条件的研究中检索个体参与者资料(IPD)进行ROC曲线分析。T2*截止值为20 ms的CMR被认为是金标准。进行荟萃分析,并使用JBI检查表评估偏倚风险。结果:共有14项研究纳入了789例地中海贫血患者(分别有310例和430例伴有或不伴有CIO, 49例病情不确定),符合meta分析的条件。有405名与会者的ipd。CIO患者的GLS(-17.5±2.7%)明显低于无CIO患者(-19.9±2.3%;大规模杀伤性武器= 1.6%,95% CI = [0.76 - -2.4], p = 0.001, I2 = 77.1%)和正常人群(-20.61±2.26%;大规模杀伤性武器= 2.2%,95% CI = (0.91 - -3.5), I2 = 83.9%, p = 0.001)。结论:根据我们的研究,GLS是CIO的一个强有力的预测因子,当CMR不可用时,它可能是识别地中海贫血患者CIO的一个有用的筛查方法。
Global longitudinal strain for detection of cardiac iron overload in patients with thalassemia: a meta-analysis of observational studies with individual-level participant data.
Background: Although cardiac magnetic resonance (CMR) is the most reliable tool for assessment of CIO in patients with thalassemia, it is not always readily available. Recent studies have explored the potential of GLS as an alternative for diagnosis of CIO. We aimed to investigate the efficacy of global longitudinal strain (GLS) for detection of cardiac iron level (CIO).
Methods: We searched SCOPUS, MEDLINE, and Embase to identify the studies which used GLS for assessment of CIO. We searched for individual participant data (IPD) in eligible studies to perform ROC curve analysis. CMR with a T2* cut-off value of 20 ms was considered as the gold standard. A meta-analysis was performed and the risk of bias was assessed using the JBI Checklist.
Results: A total of 14 studies with 789 thalassemia patients (310 and 430 with and without CIO respectively and 49 with undetermined condition) were considered eligible for meta-analysis. IPDs of 405 participants were available. GLS was significantly lower in patients with CIO (-17.5 ± 2.7%) compared to those without CIO (-19.9 ± 2.3%; WMD = 1.6%, 95% CI = [0.76-2.4], p = 0.001, I2 = 77.1%) and to normal population (-20.61 ± 2.26%; WMD = 2.2%, 95% CI = [0.91-3.5], p = 0.001, I2 = 83.9%). A GLS < -19.5% could predict CIO with 92.8% sensitivity and 34.63% specificity (AUC = 0.659, 95% CI = [0.6-0.72], p-value < 0.0001). A GLS value < -6% has 100% positive predictive and ≥ -24.5% has 100% negative predictive values for detection of CIO.
Conclusions: According to our study, GLS is a strong predictor of CIO and when CMR is not available, it may be a useful screening method for identification of CIO in thalassemia patients.
期刊介绍:
Cardiovascular Ultrasound is an online journal, publishing peer-reviewed: original research; authoritative reviews; case reports on challenging and/or unusual diagnostic aspects; and expert opinions on new techniques and technologies. We are particularly interested in articles that include relevant images or video files, which provide an additional dimension to published articles and enhance understanding.
As an open access journal, Cardiovascular Ultrasound ensures high visibility for authors in addition to providing an up-to-date and freely available resource for the community. The journal welcomes discussion, and provides a forum for publishing opinion and debate ranging from biology to engineering to clinical echocardiography, with both speed and versatility.