T Knight, P Parulekar, G Rudge, F Lesser, M Dachsel, A Aujayeb, D Lasserson, N Smallwood
{"title":"即时肺部超声在COVID-19评估中的应用:英国一项多中心服务评估结果","authors":"T Knight, P Parulekar, G Rudge, F Lesser, M Dachsel, A Aujayeb, D Lasserson, N Smallwood","doi":"10.52964/AMJA.0912","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Coronavirus disease 2019 has had a dramatic impact on the delivery of acute care globally. Accurate risk stratification is fundamental to the efficient organisation of care. Point-of-care lung ultrasound offers practical advantages over conventional imaging with potential to improve the operational performance of acute care pathways during periods of high demand. The Society for Acute Medicine and the Intensive Care Society undertook a collaborative evaluation of point-of-care imaging in the UK to describe the scope of current practice and explore performance during real-world application.</p><p><strong>Methods: </strong>A retrospective service evaluation was undertaken of the use of point-of-care lung ultrasound during the initial wave of coronavirus infection in the UK. We report an evaluation of all imaging studies performed outside the intensive care unit. An ordinal scale was used to measure the severity of loss of lung aeration. The relationship between lung ultrasound, polymerase chain reaction for SARS-CoV-2 and 30-day outcomes were described using logistic regression models.</p><p><strong>Results: </strong>Data were collected from 7 hospitals between February and September 2020. In total, 297 ultrasound examinations from 295 patients were recorded. Nasopharyngeal swab samples were positive in 145 patients (49.2% 95%CI 43.5-54.8). A multivariate model combining three ultrasound variables showed reasonable discrimination in relation to the polymerase chain reaction reference (AUC 0.77 95%CI 0.71-0.82). The composite outcome of death or intensive care admission at 30 days occurred in 83 (28.1%, 95%CI 23.3-33.5). Lung ultrasound was able to discriminate the composite outcome with a reasonable level of accuracy (AUC 0.76 95%CI 0.69-0.83) in univariate analysis. The relationship remained statistically significant in a multivariate model controlled for age, sex and the time interval from admission to scan Conclusion: Point-of-care lung ultrasound is able to discriminate patients at increased risk of deterioration allowing more informed clinical decision making.</p>","PeriodicalId":39743,"journal":{"name":"Acute Medicine","volume":"21 3","pages":"131-138"},"PeriodicalIF":0.0000,"publicationDate":"2022-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Point-of-care lung ultrasound in the assessment of COVID-19: results of a UK multicentre service evaluation.\",\"authors\":\"T Knight, P Parulekar, G Rudge, F Lesser, M Dachsel, A Aujayeb, D Lasserson, N Smallwood\",\"doi\":\"10.52964/AMJA.0912\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Coronavirus disease 2019 has had a dramatic impact on the delivery of acute care globally. Accurate risk stratification is fundamental to the efficient organisation of care. Point-of-care lung ultrasound offers practical advantages over conventional imaging with potential to improve the operational performance of acute care pathways during periods of high demand. The Society for Acute Medicine and the Intensive Care Society undertook a collaborative evaluation of point-of-care imaging in the UK to describe the scope of current practice and explore performance during real-world application.</p><p><strong>Methods: </strong>A retrospective service evaluation was undertaken of the use of point-of-care lung ultrasound during the initial wave of coronavirus infection in the UK. We report an evaluation of all imaging studies performed outside the intensive care unit. An ordinal scale was used to measure the severity of loss of lung aeration. The relationship between lung ultrasound, polymerase chain reaction for SARS-CoV-2 and 30-day outcomes were described using logistic regression models.</p><p><strong>Results: </strong>Data were collected from 7 hospitals between February and September 2020. In total, 297 ultrasound examinations from 295 patients were recorded. Nasopharyngeal swab samples were positive in 145 patients (49.2% 95%CI 43.5-54.8). A multivariate model combining three ultrasound variables showed reasonable discrimination in relation to the polymerase chain reaction reference (AUC 0.77 95%CI 0.71-0.82). The composite outcome of death or intensive care admission at 30 days occurred in 83 (28.1%, 95%CI 23.3-33.5). Lung ultrasound was able to discriminate the composite outcome with a reasonable level of accuracy (AUC 0.76 95%CI 0.69-0.83) in univariate analysis. The relationship remained statistically significant in a multivariate model controlled for age, sex and the time interval from admission to scan Conclusion: Point-of-care lung ultrasound is able to discriminate patients at increased risk of deterioration allowing more informed clinical decision making.</p>\",\"PeriodicalId\":39743,\"journal\":{\"name\":\"Acute Medicine\",\"volume\":\"21 3\",\"pages\":\"131-138\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acute Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.52964/AMJA.0912\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acute Medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.52964/AMJA.0912","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
Point-of-care lung ultrasound in the assessment of COVID-19: results of a UK multicentre service evaluation.
Background: Coronavirus disease 2019 has had a dramatic impact on the delivery of acute care globally. Accurate risk stratification is fundamental to the efficient organisation of care. Point-of-care lung ultrasound offers practical advantages over conventional imaging with potential to improve the operational performance of acute care pathways during periods of high demand. The Society for Acute Medicine and the Intensive Care Society undertook a collaborative evaluation of point-of-care imaging in the UK to describe the scope of current practice and explore performance during real-world application.
Methods: A retrospective service evaluation was undertaken of the use of point-of-care lung ultrasound during the initial wave of coronavirus infection in the UK. We report an evaluation of all imaging studies performed outside the intensive care unit. An ordinal scale was used to measure the severity of loss of lung aeration. The relationship between lung ultrasound, polymerase chain reaction for SARS-CoV-2 and 30-day outcomes were described using logistic regression models.
Results: Data were collected from 7 hospitals between February and September 2020. In total, 297 ultrasound examinations from 295 patients were recorded. Nasopharyngeal swab samples were positive in 145 patients (49.2% 95%CI 43.5-54.8). A multivariate model combining three ultrasound variables showed reasonable discrimination in relation to the polymerase chain reaction reference (AUC 0.77 95%CI 0.71-0.82). The composite outcome of death or intensive care admission at 30 days occurred in 83 (28.1%, 95%CI 23.3-33.5). Lung ultrasound was able to discriminate the composite outcome with a reasonable level of accuracy (AUC 0.76 95%CI 0.69-0.83) in univariate analysis. The relationship remained statistically significant in a multivariate model controlled for age, sex and the time interval from admission to scan Conclusion: Point-of-care lung ultrasound is able to discriminate patients at increased risk of deterioration allowing more informed clinical decision making.
期刊介绍:
These are usually commissioned by the editorial team in accordance with a cycle running over several years. Authors wishing to submit a review relevant to Acute Medicine are advised to contact the editor before writing this. Unsolicited review articles received for consideration may be included if the subject matter is considered of interest to the readership, provided the topic has not already been covered in a recent edition. Review articles are usually 3000-5000 words and may include tables, pictures and other figures as required for the text. Include 3 or 4 ‘key points’ summarising the main teaching messages.