Theresa L Aller, David Sanchez-Migallon Guzman, Joshua A Stern, Jamie M Douglas, Bryce M Golsen, Tracy L Drazenovich, Joanne Paul-Murphy
{"title":"伊斯帕尼奥兰亚马逊鹦鹉(腹侧亚马逊鹦鹉)透视血管造影方案的评价。","authors":"Theresa L Aller, David Sanchez-Migallon Guzman, Joshua A Stern, Jamie M Douglas, Bryce M Golsen, Tracy L Drazenovich, Joanne Paul-Murphy","doi":"10.1647/21-00007","DOIUrl":null,"url":null,"abstract":"<p><p>Fluoroscopic angiography evaluates the heart and vascular tree in real time and can be recorded for further diagnostic analysis and measurements. Although reports have been published of the use of fluoroscopic angiography in birds, this technique has not been evaluated in any avian species. The purpose of this study was to evaluate a fluoroscopic angiography protocol in 12 adult Hispaniolan Amazon parrots (<i>Amazona ventralis</i>). Under general anesthesia, the birds were positioned in right lateral (LAT) recumbency on a fluoroscopy table. A bolus of nonionic iodinated contrast agent was injected through a catheter inserted into the basilic or medial metatarsal vein during video acquisition. The same bolus was repeated to obtain the ventrodorsal (VD) view with the bird placed in dorsal recumbency. Eleven studies were performed. A total of 19 (10 VD, 9 LAT) continuous, real-time, fluoroscopic angiograms were successfully captured. The brachiocephalic trunk, aorta, pulmonary arteries, pulmonary veins, and caudal vena cava were visualized, and selected intraluminal measurements collected. The intraobserver and interobserver variability for 3 observers was calculated. Intraobserver agreement was found to be near perfect (intraclass correlation coefficient ≥0.95), whereas interobserver agreement was moderate to substantial (intraclass correlation coefficient ≥0.52). Coefficients of variation were excellent (VD 0.99, LAT 0.99) for intraobserver assessments and moderate (VD 0.72, LAT 0.52) for interobserver assessments. For the interobserver assessments, the VD projection measurements performed better than the LAT measurements. These results suggest that although there was some variation between different observers, relatively consistent vascular measurements could be obtained. The described fluoroscopic angiography protocol is a repeatable and reliable technique that could be useful for the diagnosis and monitoring of cardiovascular diseases in birds.</p>","PeriodicalId":15102,"journal":{"name":"Journal of Avian Medicine and Surgery","volume":"36 2","pages":"178-186"},"PeriodicalIF":0.6000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Evaluation of a Fluoroscopic Angiography Protocol in Hispaniolan Amazon Parrots (<i>Amazona ventralis</i>).\",\"authors\":\"Theresa L Aller, David Sanchez-Migallon Guzman, Joshua A Stern, Jamie M Douglas, Bryce M Golsen, Tracy L Drazenovich, Joanne Paul-Murphy\",\"doi\":\"10.1647/21-00007\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Fluoroscopic angiography evaluates the heart and vascular tree in real time and can be recorded for further diagnostic analysis and measurements. Although reports have been published of the use of fluoroscopic angiography in birds, this technique has not been evaluated in any avian species. The purpose of this study was to evaluate a fluoroscopic angiography protocol in 12 adult Hispaniolan Amazon parrots (<i>Amazona ventralis</i>). Under general anesthesia, the birds were positioned in right lateral (LAT) recumbency on a fluoroscopy table. A bolus of nonionic iodinated contrast agent was injected through a catheter inserted into the basilic or medial metatarsal vein during video acquisition. The same bolus was repeated to obtain the ventrodorsal (VD) view with the bird placed in dorsal recumbency. Eleven studies were performed. A total of 19 (10 VD, 9 LAT) continuous, real-time, fluoroscopic angiograms were successfully captured. The brachiocephalic trunk, aorta, pulmonary arteries, pulmonary veins, and caudal vena cava were visualized, and selected intraluminal measurements collected. The intraobserver and interobserver variability for 3 observers was calculated. Intraobserver agreement was found to be near perfect (intraclass correlation coefficient ≥0.95), whereas interobserver agreement was moderate to substantial (intraclass correlation coefficient ≥0.52). Coefficients of variation were excellent (VD 0.99, LAT 0.99) for intraobserver assessments and moderate (VD 0.72, LAT 0.52) for interobserver assessments. For the interobserver assessments, the VD projection measurements performed better than the LAT measurements. These results suggest that although there was some variation between different observers, relatively consistent vascular measurements could be obtained. The described fluoroscopic angiography protocol is a repeatable and reliable technique that could be useful for the diagnosis and monitoring of cardiovascular diseases in birds.</p>\",\"PeriodicalId\":15102,\"journal\":{\"name\":\"Journal of Avian Medicine and Surgery\",\"volume\":\"36 2\",\"pages\":\"178-186\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2022-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Avian Medicine and Surgery\",\"FirstCategoryId\":\"97\",\"ListUrlMain\":\"https://doi.org/10.1647/21-00007\",\"RegionNum\":4,\"RegionCategory\":\"农林科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"VETERINARY SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Avian Medicine and Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1647/21-00007","RegionNum":4,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
摘要
透视血管造影可实时评估心脏和血管树,并可记录以作进一步的诊断分析和测量。虽然已经发表了在鸟类中使用透视血管造影的报告,但该技术尚未在任何鸟类物种中进行评估。本研究的目的是评估12只成年伊斯帕尼奥兰亚马逊鹦鹉(腹侧亚马逊鹦鹉)的透视血管造影方案。在全身麻醉下,将雏鸟置于透视台上右侧侧卧位(LAT)。在视频采集期间,通过导管插入基底静脉或内侧跖静脉注射非离子碘化造影剂。在鸟背部平卧的情况下,重复相同的剂量以获得腹背侧(VD)视图。共进行了11项研究。共成功捕获19张(10张VD, 9张LAT)连续、实时的透视血管图。观察头臂干、主动脉、肺动脉、肺静脉和尾腔静脉,并收集腔内测量数据。计算3个观测者的观测者内部和观测者之间的变异性。观察者内部的一致性接近完美(类内相关系数≥0.95),而观察者之间的一致性为中等至实质性(类内相关系数≥0.52)。观察者内部评价的变异系数为优秀(VD 0.99, LAT 0.99),观察者间评价的变异系数为中等(VD 0.72, LAT 0.52)。对于观察者间的评估,VD投影测量比LAT测量表现更好。这些结果表明,尽管不同观测者之间存在一些差异,但可以获得相对一致的血管测量结果。所描述的透视血管造影方案是一种可重复和可靠的技术,可用于诊断和监测鸟类心血管疾病。
Evaluation of a Fluoroscopic Angiography Protocol in Hispaniolan Amazon Parrots (Amazona ventralis).
Fluoroscopic angiography evaluates the heart and vascular tree in real time and can be recorded for further diagnostic analysis and measurements. Although reports have been published of the use of fluoroscopic angiography in birds, this technique has not been evaluated in any avian species. The purpose of this study was to evaluate a fluoroscopic angiography protocol in 12 adult Hispaniolan Amazon parrots (Amazona ventralis). Under general anesthesia, the birds were positioned in right lateral (LAT) recumbency on a fluoroscopy table. A bolus of nonionic iodinated contrast agent was injected through a catheter inserted into the basilic or medial metatarsal vein during video acquisition. The same bolus was repeated to obtain the ventrodorsal (VD) view with the bird placed in dorsal recumbency. Eleven studies were performed. A total of 19 (10 VD, 9 LAT) continuous, real-time, fluoroscopic angiograms were successfully captured. The brachiocephalic trunk, aorta, pulmonary arteries, pulmonary veins, and caudal vena cava were visualized, and selected intraluminal measurements collected. The intraobserver and interobserver variability for 3 observers was calculated. Intraobserver agreement was found to be near perfect (intraclass correlation coefficient ≥0.95), whereas interobserver agreement was moderate to substantial (intraclass correlation coefficient ≥0.52). Coefficients of variation were excellent (VD 0.99, LAT 0.99) for intraobserver assessments and moderate (VD 0.72, LAT 0.52) for interobserver assessments. For the interobserver assessments, the VD projection measurements performed better than the LAT measurements. These results suggest that although there was some variation between different observers, relatively consistent vascular measurements could be obtained. The described fluoroscopic angiography protocol is a repeatable and reliable technique that could be useful for the diagnosis and monitoring of cardiovascular diseases in birds.
期刊介绍:
The Journal of Avian Medicine and Surgery is an international journal of the medicine and surgery of both captive and wild birds. Published materials include scientific articles, case reports, editorials, abstracts, new research, and book reviews.