结合杯体方向和阀杆型号确定带唇衬管的最佳位置。

IF 4.7 2区 医学 Q2 CELL & TISSUE ENGINEERING Bone & Joint Research Pub Date : 2023-09-20 DOI:10.1302/2046-3758.129.BJR-2022-0471.R1
Alessandro Navacchia, Joseph Pagkalos, Edward T Davis
{"title":"结合杯体方向和阀杆型号确定带唇衬管的最佳位置。","authors":"Alessandro Navacchia,&nbsp;Joseph Pagkalos,&nbsp;Edward T Davis","doi":"10.1302/2046-3758.129.BJR-2022-0471.R1","DOIUrl":null,"url":null,"abstract":"<p><strong>Aims: </strong>The aim of this study was to identify the optimal lip position for total hip arthroplasties (THAs) using a lipped liner. There is a lack of consensus on the optimal position, with substantial variability in surgeon practice.</p><p><strong>Methods: </strong>A model of a THA was developed using a 20° lipped liner. Kinematic analyses included a physiological range of motion (ROM) analysis and a provocative dislocation manoeuvre analysis. ROM prior to impingement was calculated and, in impingement scenarios, the travel distance prior to dislocation was assessed. The combinations analyzed included nine cup positions (inclination 30-40-50°, anteversion 5-15-25°), three stem positions (anteversion 0-15-30°), and five lip orientations (right hip 7 to 11 o'clock).</p><p><strong>Results: </strong>The position of the lip changes the ROM prior to impingement, with certain combinations leading to impingement within the physiological ROM. Inferior lip positions (7 to 8 o'clock) performed best with cup inclinations of 30° and 40°. Superior lip positions performed best with cup inclination of 50°. When impingement occurs in the plane of the lip, the lip increases the travel distance prior to dislocation. Inferior lip positions led to the largest increase in jump distance in a posterior dislocation provocation manoeuvre.</p><p><strong>Conclusion: </strong>The lip orientation that provides optimal physiological ROM depends on the orientation of the cup and stem. For a THA with stem anteversion 15°, cup inclination 40°, and cup anteversion 15°, the optimal lip position was posterior-inferior (8 o'clock). Maximizing jump distance prior to dislocation while preventing impingement in the opposite direction is possible with appropriate lip positioning.</p>","PeriodicalId":9074,"journal":{"name":"Bone & Joint Research","volume":null,"pages":null},"PeriodicalIF":4.7000,"publicationDate":"2023-09-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/78/d3/BJR-12-2046-3758.129.BJR-2022-0471.R1.PMC10509720.pdf","citationCount":"0","resultStr":"{\"title\":\"Defining the optimal position of the lipped liner in combination with cup orientation and stem version.\",\"authors\":\"Alessandro Navacchia,&nbsp;Joseph Pagkalos,&nbsp;Edward T Davis\",\"doi\":\"10.1302/2046-3758.129.BJR-2022-0471.R1\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Aims: </strong>The aim of this study was to identify the optimal lip position for total hip arthroplasties (THAs) using a lipped liner. There is a lack of consensus on the optimal position, with substantial variability in surgeon practice.</p><p><strong>Methods: </strong>A model of a THA was developed using a 20° lipped liner. Kinematic analyses included a physiological range of motion (ROM) analysis and a provocative dislocation manoeuvre analysis. ROM prior to impingement was calculated and, in impingement scenarios, the travel distance prior to dislocation was assessed. The combinations analyzed included nine cup positions (inclination 30-40-50°, anteversion 5-15-25°), three stem positions (anteversion 0-15-30°), and five lip orientations (right hip 7 to 11 o'clock).</p><p><strong>Results: </strong>The position of the lip changes the ROM prior to impingement, with certain combinations leading to impingement within the physiological ROM. Inferior lip positions (7 to 8 o'clock) performed best with cup inclinations of 30° and 40°. Superior lip positions performed best with cup inclination of 50°. When impingement occurs in the plane of the lip, the lip increases the travel distance prior to dislocation. Inferior lip positions led to the largest increase in jump distance in a posterior dislocation provocation manoeuvre.</p><p><strong>Conclusion: </strong>The lip orientation that provides optimal physiological ROM depends on the orientation of the cup and stem. For a THA with stem anteversion 15°, cup inclination 40°, and cup anteversion 15°, the optimal lip position was posterior-inferior (8 o'clock). Maximizing jump distance prior to dislocation while preventing impingement in the opposite direction is possible with appropriate lip positioning.</p>\",\"PeriodicalId\":9074,\"journal\":{\"name\":\"Bone & Joint Research\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":4.7000,\"publicationDate\":\"2023-09-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/78/d3/BJR-12-2046-3758.129.BJR-2022-0471.R1.PMC10509720.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bone & Joint Research\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1302/2046-3758.129.BJR-2022-0471.R1\",\"RegionNum\":2,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"CELL & TISSUE ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bone & Joint Research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1302/2046-3758.129.BJR-2022-0471.R1","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CELL & TISSUE ENGINEERING","Score":null,"Total":0}
引用次数: 0

摘要

目的:本研究的目的是确定使用唇衬进行全髋关节置换术(THAs)的最佳唇位。对于最佳位置缺乏共识,外科医生的实践也存在很大差异。方法:使用20°唇衬建立THA模型。运动学分析包括生理活动范围(ROM)分析和挑衅性脱位动作分析。计算撞击前的ROM,并在撞击场景中评估脱位前的行进距离。所分析的组合包括九个杯状位置(倾斜30-40-50°,前倾5-15-25°)、三个柄部位置(前倾0-15-30°)和五个嘴唇方向(右髋7-11点钟)。结果:嘴唇的位置在撞击前会改变ROM,某些组合会导致生理ROM内的撞击。下唇位置(7到8点钟)表现最好,杯状倾斜30°和40°。上唇位置在杯状物倾斜50°时表现最佳。当撞击发生在唇缘的平面内时,唇缘会增加位错前的行进距离。下唇位置导致后脱位挑衅动作中跳跃距离的最大增加。结论:提供最佳生理ROM的唇部方向取决于杯状物和柄的方向。对于干前倾15°、杯状倾斜度40°和杯状前倾15度的THA,最佳唇部位置为后下(8点钟)。通过适当的唇部定位,可以在脱位前最大限度地增加跳跃距离,同时防止相反方向的撞击。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Defining the optimal position of the lipped liner in combination with cup orientation and stem version.

Aims: The aim of this study was to identify the optimal lip position for total hip arthroplasties (THAs) using a lipped liner. There is a lack of consensus on the optimal position, with substantial variability in surgeon practice.

Methods: A model of a THA was developed using a 20° lipped liner. Kinematic analyses included a physiological range of motion (ROM) analysis and a provocative dislocation manoeuvre analysis. ROM prior to impingement was calculated and, in impingement scenarios, the travel distance prior to dislocation was assessed. The combinations analyzed included nine cup positions (inclination 30-40-50°, anteversion 5-15-25°), three stem positions (anteversion 0-15-30°), and five lip orientations (right hip 7 to 11 o'clock).

Results: The position of the lip changes the ROM prior to impingement, with certain combinations leading to impingement within the physiological ROM. Inferior lip positions (7 to 8 o'clock) performed best with cup inclinations of 30° and 40°. Superior lip positions performed best with cup inclination of 50°. When impingement occurs in the plane of the lip, the lip increases the travel distance prior to dislocation. Inferior lip positions led to the largest increase in jump distance in a posterior dislocation provocation manoeuvre.

Conclusion: The lip orientation that provides optimal physiological ROM depends on the orientation of the cup and stem. For a THA with stem anteversion 15°, cup inclination 40°, and cup anteversion 15°, the optimal lip position was posterior-inferior (8 o'clock). Maximizing jump distance prior to dislocation while preventing impingement in the opposite direction is possible with appropriate lip positioning.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Bone & Joint Research
Bone & Joint Research CELL & TISSUE ENGINEERING-ORTHOPEDICS
CiteScore
7.40
自引率
23.90%
发文量
156
审稿时长
12 weeks
期刊介绍: The gold open access journal for the musculoskeletal sciences. Included in PubMed and available in PubMed Central.
期刊最新文献
Identification of age-related genes in rotator cuff tendon. The interactions of macrophages, lymphocytes, and mesenchymal stem cells during bone regeneration. Mechanical influence of facet tropism in patients with chronic discogenic pain disorder. Sonodynamic effect based on vancomycin-loaded microbubbles or meropenem-loaded microbubbles enhances elimination of different biofilms and bactericidal efficacy. Guanylate cyclase promotes osseointegration by inhibiting oxidative stress and inflammation in aged rats with iron overload.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1