Sabahattin Yüzkan, Samet Mutlu, Mehmet Karagülle, Merve Şam Özdemir, Hamit Özgül, Mehmet Ali Arıkan, Burak Koçak
{"title":"使用T2*加权灌注MRI对胶质母细胞瘤中rCBV的再现性:采样、标准化和经验的评估。","authors":"Sabahattin Yüzkan, Samet Mutlu, Mehmet Karagülle, Merve Şam Özdemir, Hamit Özgül, Mehmet Ali Arıkan, Burak Koçak","doi":"10.4274/dir.2023.232442","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The reproducibility of relative cerebral blood volume (rCBV) measurements among readers with different levels of experience is a concern. This study aimed to investigate the inter-reader reproducibility of rCBV measurement of glioblastomas using the hotspot method in dynamic susceptibility contrast perfusion magnetic resonance imaging (DSC-MRI) with various strategies.</p><p><strong>Methods: </strong>In this institutional review board-approved single-center study, 30 patients with glioblastoma were retrospectively evaluated with DSC-MRI at a 3.0 Tesla scanner. Three groups of reviewers, including neuroradiologists, general radiologists, and radiology residents, calculated the rCBV based on the number of regions of interest (ROIs) and reference areas. For statistical analysis of feature reproducibility, the intraclass correlation coefficient (ICC) and Bland-Altman plots were used. Analyses were made among individuals, reader groups, reader-group pooling, and a population that contained all of them.</p><p><strong>Results: </strong>For individuals, the highest inter-reader reproducibility was observed between neuroradiologists [ICC: 0.527; 95% confidence interval (CI): 0.21-0.74] and between residents (ICC: 0.513; 95% CI: 0.20-0.73). There was poor reproducibility in the analyses of individuals with different levels of experience (ICC range: 0.296-0.335) and in reader-wise and group-wise pooling (ICC range: 0.296-0.335 and 0.397-0.427, respectively). However, an increase in ICC values was observed when five ROIs were used. In an analysis of all strategies, the ICC for the centrum semiovale was significantly higher than that for contralateral white matter (<i>P</i> < 0.001).</p><p><strong>Conclusion: </strong>The inter-reader reproducibility of rCBV measurement was poor to moderate regardless of whether it was calculated by neuroradiologists, general radiologists, or residents, which may indicate the need for automated methods. Choosing five ROIs and using the centrum semiovale as a reference area may increase reliability for all users.</p>","PeriodicalId":11341,"journal":{"name":"Diagnostic and interventional radiology","volume":null,"pages":null},"PeriodicalIF":1.4000,"publicationDate":"2024-03-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10916530/pdf/","citationCount":"0","resultStr":"{\"title\":\"Reproducibility of rCBV in glioblastomas using T2*-weighted perfusion MRI: an evaluation of sampling, normalization, and experience.\",\"authors\":\"Sabahattin Yüzkan, Samet Mutlu, Mehmet Karagülle, Merve Şam Özdemir, Hamit Özgül, Mehmet Ali Arıkan, Burak Koçak\",\"doi\":\"10.4274/dir.2023.232442\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>The reproducibility of relative cerebral blood volume (rCBV) measurements among readers with different levels of experience is a concern. This study aimed to investigate the inter-reader reproducibility of rCBV measurement of glioblastomas using the hotspot method in dynamic susceptibility contrast perfusion magnetic resonance imaging (DSC-MRI) with various strategies.</p><p><strong>Methods: </strong>In this institutional review board-approved single-center study, 30 patients with glioblastoma were retrospectively evaluated with DSC-MRI at a 3.0 Tesla scanner. Three groups of reviewers, including neuroradiologists, general radiologists, and radiology residents, calculated the rCBV based on the number of regions of interest (ROIs) and reference areas. For statistical analysis of feature reproducibility, the intraclass correlation coefficient (ICC) and Bland-Altman plots were used. Analyses were made among individuals, reader groups, reader-group pooling, and a population that contained all of them.</p><p><strong>Results: </strong>For individuals, the highest inter-reader reproducibility was observed between neuroradiologists [ICC: 0.527; 95% confidence interval (CI): 0.21-0.74] and between residents (ICC: 0.513; 95% CI: 0.20-0.73). There was poor reproducibility in the analyses of individuals with different levels of experience (ICC range: 0.296-0.335) and in reader-wise and group-wise pooling (ICC range: 0.296-0.335 and 0.397-0.427, respectively). However, an increase in ICC values was observed when five ROIs were used. In an analysis of all strategies, the ICC for the centrum semiovale was significantly higher than that for contralateral white matter (<i>P</i> < 0.001).</p><p><strong>Conclusion: </strong>The inter-reader reproducibility of rCBV measurement was poor to moderate regardless of whether it was calculated by neuroradiologists, general radiologists, or residents, which may indicate the need for automated methods. Choosing five ROIs and using the centrum semiovale as a reference area may increase reliability for all users.</p>\",\"PeriodicalId\":11341,\"journal\":{\"name\":\"Diagnostic and interventional radiology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2024-03-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10916530/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic and interventional radiology\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.4274/dir.2023.232442\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/3 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and interventional radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4274/dir.2023.232442","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/3 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
Reproducibility of rCBV in glioblastomas using T2*-weighted perfusion MRI: an evaluation of sampling, normalization, and experience.
Purpose: The reproducibility of relative cerebral blood volume (rCBV) measurements among readers with different levels of experience is a concern. This study aimed to investigate the inter-reader reproducibility of rCBV measurement of glioblastomas using the hotspot method in dynamic susceptibility contrast perfusion magnetic resonance imaging (DSC-MRI) with various strategies.
Methods: In this institutional review board-approved single-center study, 30 patients with glioblastoma were retrospectively evaluated with DSC-MRI at a 3.0 Tesla scanner. Three groups of reviewers, including neuroradiologists, general radiologists, and radiology residents, calculated the rCBV based on the number of regions of interest (ROIs) and reference areas. For statistical analysis of feature reproducibility, the intraclass correlation coefficient (ICC) and Bland-Altman plots were used. Analyses were made among individuals, reader groups, reader-group pooling, and a population that contained all of them.
Results: For individuals, the highest inter-reader reproducibility was observed between neuroradiologists [ICC: 0.527; 95% confidence interval (CI): 0.21-0.74] and between residents (ICC: 0.513; 95% CI: 0.20-0.73). There was poor reproducibility in the analyses of individuals with different levels of experience (ICC range: 0.296-0.335) and in reader-wise and group-wise pooling (ICC range: 0.296-0.335 and 0.397-0.427, respectively). However, an increase in ICC values was observed when five ROIs were used. In an analysis of all strategies, the ICC for the centrum semiovale was significantly higher than that for contralateral white matter (P < 0.001).
Conclusion: The inter-reader reproducibility of rCBV measurement was poor to moderate regardless of whether it was calculated by neuroradiologists, general radiologists, or residents, which may indicate the need for automated methods. Choosing five ROIs and using the centrum semiovale as a reference area may increase reliability for all users.
期刊介绍:
Diagnostic and Interventional Radiology (Diagn Interv Radiol) is the open access, online-only official publication of Turkish Society of Radiology. It is published bimonthly and the journal’s publication language is English.
The journal is a medium for original articles, reviews, pictorial essays, technical notes related to all fields of diagnostic and interventional radiology.