六阶段法在印度人群耳廓年龄估计中的适用性:一项基于CT的研究。

IF 1.5 4区 医学 Q1 LAW Medicine, Science and the Law Pub Date : 2023-10-12 DOI:10.1177/00258024231206864
Varsha Warrier, Rutwik Shedge, Pawan Kumar Garg, Shilpi Gupta Dixit, Kewal Krishan, Tanuj Kanchan
{"title":"六阶段法在印度人群耳廓年龄估计中的适用性:一项基于CT的研究。","authors":"Varsha Warrier,&nbsp;Rutwik Shedge,&nbsp;Pawan Kumar Garg,&nbsp;Shilpi Gupta Dixit,&nbsp;Kewal Krishan,&nbsp;Tanuj Kanchan","doi":"10.1177/00258024231206864","DOIUrl":null,"url":null,"abstract":"<p><p>Age estimation plays a crucial role in human identification. Amongst numerous age markers located throughout the skeletal framework, the auricular surface of the ilium presents as a resilient structure, with different methods for auricular age estimation currently in practice. Amongst these methods, the Osborne method is believed to permit accurate age estimation through its use of robust age categories and discrete phase descriptors. The present study aimed to assess the applicability of the Osborne method in an Indian population through a computed tomographic (CT) examination of the auricular surface, an aspect presently unreported. In order to do so, CT scans of 380 individuals were collected and evaluated using the Osborne method. A CT-based examination indicated that surface texture described by Osborne is difficult to appreciate through 3D CT images. Indistinct definitions associated with certain features, and the mosaic display of features within each phase further prevents applying the method effectively. Overall accuracy percentages of 99.47% and 98.90% were obtained using the method in males and females, respectively, with corresponding inaccuracy values of 10.10 years and 9.04 years. Significantly reduced accuracy percentages were obtained with alternate, more robust age brackets presented within the original study, demonstrating the limited reliability associated with the method. Inaccuracy and bias values computed for each decade indicate the relative utility of the method in aging 40-59-year-old individuals. Low accuracy percentages, high error rates and different methodological hindrances encountered within the present study illustrate the limited applicability of the Osborne method in aging an Indian population.</p>","PeriodicalId":18484,"journal":{"name":"Medicine, Science and the Law","volume":null,"pages":null},"PeriodicalIF":1.5000,"publicationDate":"2023-10-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Applicability of the six-phase method for auricular age estimation in an Indian population: A CT-based study.\",\"authors\":\"Varsha Warrier,&nbsp;Rutwik Shedge,&nbsp;Pawan Kumar Garg,&nbsp;Shilpi Gupta Dixit,&nbsp;Kewal Krishan,&nbsp;Tanuj Kanchan\",\"doi\":\"10.1177/00258024231206864\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Age estimation plays a crucial role in human identification. Amongst numerous age markers located throughout the skeletal framework, the auricular surface of the ilium presents as a resilient structure, with different methods for auricular age estimation currently in practice. Amongst these methods, the Osborne method is believed to permit accurate age estimation through its use of robust age categories and discrete phase descriptors. The present study aimed to assess the applicability of the Osborne method in an Indian population through a computed tomographic (CT) examination of the auricular surface, an aspect presently unreported. In order to do so, CT scans of 380 individuals were collected and evaluated using the Osborne method. A CT-based examination indicated that surface texture described by Osborne is difficult to appreciate through 3D CT images. Indistinct definitions associated with certain features, and the mosaic display of features within each phase further prevents applying the method effectively. Overall accuracy percentages of 99.47% and 98.90% were obtained using the method in males and females, respectively, with corresponding inaccuracy values of 10.10 years and 9.04 years. Significantly reduced accuracy percentages were obtained with alternate, more robust age brackets presented within the original study, demonstrating the limited reliability associated with the method. Inaccuracy and bias values computed for each decade indicate the relative utility of the method in aging 40-59-year-old individuals. Low accuracy percentages, high error rates and different methodological hindrances encountered within the present study illustrate the limited applicability of the Osborne method in aging an Indian population.</p>\",\"PeriodicalId\":18484,\"journal\":{\"name\":\"Medicine, Science and the Law\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.5000,\"publicationDate\":\"2023-10-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medicine, Science and the Law\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1177/00258024231206864\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"LAW\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medicine, Science and the Law","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1177/00258024231206864","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"LAW","Score":null,"Total":0}
引用次数: 0

摘要

年龄估计在人类识别中起着至关重要的作用。在位于整个骨骼骨架的众多年龄标记物中,髂骨的耳廓表面呈现出弹性结构,目前有不同的耳廓年龄估计方法。在这些方法中,Osborne方法被认为通过使用稳健的年龄类别和离散相位描述符来实现准确的年龄估计。本研究旨在通过对耳廓表面的计算机断层扫描(CT)检查来评估奥斯本方法在印度人群中的适用性,这一方面目前尚未报道。为了做到这一点,收集了380人的CT扫描,并使用Osborne方法进行了评估。基于CT的检查表明,Osborne描述的表面纹理很难通过3D CT图像来欣赏。与某些特征相关联的不明确的定义,以及每个阶段内特征的马赛克显示,进一步阻碍了该方法的有效应用。使用该方法,男性和女性的总体准确率分别为99.47%和98.90%,相应的不准确值分别为10.10年和9.04年。在最初的研究中,使用替代的、更稳健的年龄段,获得了显著降低的准确率百分比,这表明与该方法相关的可靠性有限。每十年计算的不准确度和偏差值表明该方法在40-59岁老年人中的相对效用。本研究中遇到的低准确率、高错误率和不同的方法障碍表明,奥斯本方法在印度人口老龄化中的适用性有限。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Applicability of the six-phase method for auricular age estimation in an Indian population: A CT-based study.

Age estimation plays a crucial role in human identification. Amongst numerous age markers located throughout the skeletal framework, the auricular surface of the ilium presents as a resilient structure, with different methods for auricular age estimation currently in practice. Amongst these methods, the Osborne method is believed to permit accurate age estimation through its use of robust age categories and discrete phase descriptors. The present study aimed to assess the applicability of the Osborne method in an Indian population through a computed tomographic (CT) examination of the auricular surface, an aspect presently unreported. In order to do so, CT scans of 380 individuals were collected and evaluated using the Osborne method. A CT-based examination indicated that surface texture described by Osborne is difficult to appreciate through 3D CT images. Indistinct definitions associated with certain features, and the mosaic display of features within each phase further prevents applying the method effectively. Overall accuracy percentages of 99.47% and 98.90% were obtained using the method in males and females, respectively, with corresponding inaccuracy values of 10.10 years and 9.04 years. Significantly reduced accuracy percentages were obtained with alternate, more robust age brackets presented within the original study, demonstrating the limited reliability associated with the method. Inaccuracy and bias values computed for each decade indicate the relative utility of the method in aging 40-59-year-old individuals. Low accuracy percentages, high error rates and different methodological hindrances encountered within the present study illustrate the limited applicability of the Osborne method in aging an Indian population.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medicine, Science and the Law
Medicine, Science and the Law 医学-医学:法
CiteScore
2.90
自引率
6.70%
发文量
53
审稿时长
>12 weeks
期刊介绍: Medicine, Science and the Law is the official journal of the British Academy for Forensic Sciences (BAFS). It is a peer reviewed journal dedicated to advancing the knowledge of forensic science and medicine. The journal aims to inform its readers from a broad perspective and demonstrate the interrelated nature and scope of the forensic disciplines. Through a variety of authoritative research articles submitted from across the globe, it covers a range of topical medico-legal issues. The journal keeps its readers informed of developments and trends through reporting, discussing and debating current issues of importance in forensic practice.
期刊最新文献
A review of the estimation of postmortem interval using forensic entomology Postmortem CT and MRI for detecting bowel obstruction in cases of pediatric sepsis deaths. The over-representation of neurodivergent children in Youth Justice Systems and The Youth Court. An analysis of risk factors for child suicide in three centres from 2008 to 2017. Analytical methods for the determination of xylazine in pharmaceutical, clinical and forensic matrices - A review.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1