超声引导下危重患者外周静脉插管:一项实用指南。

IF 3.4 Q2 Medicine Ultrasound Journal Pub Date : 2019-10-17 DOI:10.1186/s13089-019-0144-5
Pablo Blanco
{"title":"超声引导下危重患者外周静脉插管:一项实用指南。","authors":"Pablo Blanco","doi":"10.1186/s13089-019-0144-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Up to one-third of critically ill patients have difficult intravenous access (DIVA). This occurs often in obese patients, those with generalized edemas or in patients with previous venous cannulations. In DIVA patients, the conventional technique often fails. In contrast, ultrasound-guided cannulation has demonstrated a high success rate, improving patient satisfaction and even a reduction in the need of central venous lines. However, a high rate of premature catheter failure has been shown in cannulations performed by ultrasound guidance and thus a comprehensive knowledge of several aspects related to this procedure is mandatory to improve cannulation success, avoid complications and lengthen the survival of the catheter.</p><p><strong>Main text: </strong>Several practical issues related to peripheral venous cannulation are described: peripheral venous anatomy, vein size and catheter selection, distance from skin to vein, insertion angle and selection of the catheter length, cannulation technique itself (out-of-plane or in-plane) and checking catheter position.</p><p><strong>Conclusion: </strong>Key concepts regarding ultrasound-guided peripheral vein cannulation should be well known for practitioners, aiding in improving cannulation success and catheter dwell time, and avoiding complications.</p>","PeriodicalId":36911,"journal":{"name":"Ultrasound Journal","volume":"11 1","pages":"27"},"PeriodicalIF":3.4000,"publicationDate":"2019-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1186/s13089-019-0144-5","citationCount":"29","resultStr":"{\"title\":\"Ultrasound-guided peripheral venous cannulation in critically ill patients: a practical guideline.\",\"authors\":\"Pablo Blanco\",\"doi\":\"10.1186/s13089-019-0144-5\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Up to one-third of critically ill patients have difficult intravenous access (DIVA). This occurs often in obese patients, those with generalized edemas or in patients with previous venous cannulations. In DIVA patients, the conventional technique often fails. In contrast, ultrasound-guided cannulation has demonstrated a high success rate, improving patient satisfaction and even a reduction in the need of central venous lines. However, a high rate of premature catheter failure has been shown in cannulations performed by ultrasound guidance and thus a comprehensive knowledge of several aspects related to this procedure is mandatory to improve cannulation success, avoid complications and lengthen the survival of the catheter.</p><p><strong>Main text: </strong>Several practical issues related to peripheral venous cannulation are described: peripheral venous anatomy, vein size and catheter selection, distance from skin to vein, insertion angle and selection of the catheter length, cannulation technique itself (out-of-plane or in-plane) and checking catheter position.</p><p><strong>Conclusion: </strong>Key concepts regarding ultrasound-guided peripheral vein cannulation should be well known for practitioners, aiding in improving cannulation success and catheter dwell time, and avoiding complications.</p>\",\"PeriodicalId\":36911,\"journal\":{\"name\":\"Ultrasound Journal\",\"volume\":\"11 1\",\"pages\":\"27\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2019-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1186/s13089-019-0144-5\",\"citationCount\":\"29\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ultrasound Journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1186/s13089-019-0144-5\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ultrasound Journal","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1186/s13089-019-0144-5","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 29

摘要

背景:高达三分之一的危重患者静脉注射困难。这种情况经常发生在肥胖患者、全身性水肿患者或既往有静脉插管的患者身上。在DIVA患者中,常规技术经常失败。相比之下,超声引导插管的成功率很高,提高了患者的满意度,甚至减少了对中心静脉线路的需求。然而,在通过超声引导进行的插管中,导管过早失效的发生率很高,因此,必须全面了解与该程序相关的几个方面,以提高插管成功率,避免并发症并延长导管的生存期。正文:介绍了与外周静脉插管相关的几个实际问题:外周静脉解剖、静脉大小和导管选择、皮肤到静脉的距离、插入角度和导管长度的选择、插管技术本身(平面外或平面内)和检查导管位置。结论:超声引导下外周静脉插管的关键概念应为从业者所熟知,有助于提高插管成功率和导管停留时间,避免并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Ultrasound-guided peripheral venous cannulation in critically ill patients: a practical guideline.

Background: Up to one-third of critically ill patients have difficult intravenous access (DIVA). This occurs often in obese patients, those with generalized edemas or in patients with previous venous cannulations. In DIVA patients, the conventional technique often fails. In contrast, ultrasound-guided cannulation has demonstrated a high success rate, improving patient satisfaction and even a reduction in the need of central venous lines. However, a high rate of premature catheter failure has been shown in cannulations performed by ultrasound guidance and thus a comprehensive knowledge of several aspects related to this procedure is mandatory to improve cannulation success, avoid complications and lengthen the survival of the catheter.

Main text: Several practical issues related to peripheral venous cannulation are described: peripheral venous anatomy, vein size and catheter selection, distance from skin to vein, insertion angle and selection of the catheter length, cannulation technique itself (out-of-plane or in-plane) and checking catheter position.

Conclusion: Key concepts regarding ultrasound-guided peripheral vein cannulation should be well known for practitioners, aiding in improving cannulation success and catheter dwell time, and avoiding complications.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ultrasound Journal
Ultrasound Journal Health Professions-Radiological and Ultrasound Technology
CiteScore
6.80
自引率
2.90%
发文量
45
审稿时长
22 weeks
期刊最新文献
VExUS: common misconceptions, clinical use and future directions. Decoding VExUS: a practical guide for excelling in point-of-care ultrasound assessment of venous congestion. Quantitative lung ultrasound findings correlate with radial alveolar count in experimental bronchopulmonary dysplasia. Tele-education in point-of-care ultrasound training. Comparison of 6 handheld ultrasound devices by point-of-care ultrasound experts: a cross-sectional study.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1