使用动物模型研究针的特性以改善前房穿刺术的结果。

IF 1.9 4区 医学 Q2 OPHTHALMOLOGY Journal of Ocular Pharmacology and Therapeutics Pub Date : 2024-01-01 Epub Date: 2023-10-17 DOI:10.1089/jop.2023.0002
Reed Brockstein, Yu-Chang Chen, Curtis Marshall, Lindsay Kwok, Athanacia Papoutsis, Thomas Wei, Deana C McDonagh, Stephen Sanderson, Richard Mental, Leanne T Labriola
{"title":"使用动物模型研究针的特性以改善前房穿刺术的结果。","authors":"Reed Brockstein, Yu-Chang Chen, Curtis Marshall, Lindsay Kwok, Athanacia Papoutsis, Thomas Wei, Deana C McDonagh, Stephen Sanderson, Richard Mental, Leanne T Labriola","doi":"10.1089/jop.2023.0002","DOIUrl":null,"url":null,"abstract":"<p><p><b><i>Background/Aims:</i></b> The current standard of care to perform an anterior chamber paracentesis involves the use of a multipurpose market needle and syringe. The use of standard needles for this purpose may result in injury to the patient due to increased force with insertion and increased globe displacement during the procedure. This research investigates the current market needle characteristics and the impact of each needle characteristic on force. <b><i>Methods:</i></b> Several comparative trials were conducted to evaluate the needles. Needle characteristics of interest were gauge, primary bevel angle, number of bevels in the lancet, and needle hub geometry. Measurements of corneal insertion forces were made using a synthetic thermoplastic polyurethane medium, and bovine and porcine models. Needle safety was investigated with corneal abrasion experiments. <b><i>Results:</i></b> Reduced insertion force was observed with lower lancet primary angle. There was no difference based on the number of bevels in the lancet. Rounded hub geometry had minimal distribution to the corneal epithelium. <b><i>Conclusions:</i></b> Needle characteristics impact the force needed for needle insertion into the tissue. Since higher force can lead to increased risk and less efficiency during the procedure, reducing this force may improve the outcomes of the procedure. Needle entry can be reduced by designing an improved needle that includes a lower gauge and reduced primary angle of the lancet.</p>","PeriodicalId":16689,"journal":{"name":"Journal of Ocular Pharmacology and Therapeutics","volume":" ","pages":"100-107"},"PeriodicalIF":1.9000,"publicationDate":"2024-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of Needle Characteristics Using an Animal Model for Improved Outcomes in Anterior Chamber Paracentesis.\",\"authors\":\"Reed Brockstein, Yu-Chang Chen, Curtis Marshall, Lindsay Kwok, Athanacia Papoutsis, Thomas Wei, Deana C McDonagh, Stephen Sanderson, Richard Mental, Leanne T Labriola\",\"doi\":\"10.1089/jop.2023.0002\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p><b><i>Background/Aims:</i></b> The current standard of care to perform an anterior chamber paracentesis involves the use of a multipurpose market needle and syringe. The use of standard needles for this purpose may result in injury to the patient due to increased force with insertion and increased globe displacement during the procedure. This research investigates the current market needle characteristics and the impact of each needle characteristic on force. <b><i>Methods:</i></b> Several comparative trials were conducted to evaluate the needles. Needle characteristics of interest were gauge, primary bevel angle, number of bevels in the lancet, and needle hub geometry. Measurements of corneal insertion forces were made using a synthetic thermoplastic polyurethane medium, and bovine and porcine models. Needle safety was investigated with corneal abrasion experiments. <b><i>Results:</i></b> Reduced insertion force was observed with lower lancet primary angle. There was no difference based on the number of bevels in the lancet. Rounded hub geometry had minimal distribution to the corneal epithelium. <b><i>Conclusions:</i></b> Needle characteristics impact the force needed for needle insertion into the tissue. Since higher force can lead to increased risk and less efficiency during the procedure, reducing this force may improve the outcomes of the procedure. Needle entry can be reduced by designing an improved needle that includes a lower gauge and reduced primary angle of the lancet.</p>\",\"PeriodicalId\":16689,\"journal\":{\"name\":\"Journal of Ocular Pharmacology and Therapeutics\",\"volume\":\" \",\"pages\":\"100-107\"},\"PeriodicalIF\":1.9000,\"publicationDate\":\"2024-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Ocular Pharmacology and Therapeutics\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1089/jop.2023.0002\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q2\",\"JCRName\":\"OPHTHALMOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ocular Pharmacology and Therapeutics","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1089/jop.2023.0002","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/17 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

背景/目的:目前进行前房穿刺术的护理标准包括使用多用途市场针头和注射器。为此目的使用标准针头可能会导致患者受伤,因为在手术过程中,插入力增加,球体位移增加。本研究调查了当前市场上的针头特性以及每种针头特性对作用力的影响。方法:采用多个比较试验对针刺效果进行评价。感兴趣的针头特征包括规格、主斜角、柳叶刀中的斜面数量和针座几何形状。使用合成热塑性聚氨酯介质以及牛和猪模型测量角膜插入力。用角膜磨镶实验研究针头的安全性。结果:刺血针主角越小,插入力越小。基于柳叶刀中斜面的数量,没有差异。圆形轮毂几何形状在角膜上皮中的分布最小。结论:针头的特性会影响针头插入组织所需的力。由于在手术过程中,更大的力量会导致风险增加和效率降低,因此减少这种力量可以改善手术的结果。可以通过设计改进的针头来减少针头进入,该改进的针头包括较低的规格和减小的刺血针主角度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Investigation of Needle Characteristics Using an Animal Model for Improved Outcomes in Anterior Chamber Paracentesis.

Background/Aims: The current standard of care to perform an anterior chamber paracentesis involves the use of a multipurpose market needle and syringe. The use of standard needles for this purpose may result in injury to the patient due to increased force with insertion and increased globe displacement during the procedure. This research investigates the current market needle characteristics and the impact of each needle characteristic on force. Methods: Several comparative trials were conducted to evaluate the needles. Needle characteristics of interest were gauge, primary bevel angle, number of bevels in the lancet, and needle hub geometry. Measurements of corneal insertion forces were made using a synthetic thermoplastic polyurethane medium, and bovine and porcine models. Needle safety was investigated with corneal abrasion experiments. Results: Reduced insertion force was observed with lower lancet primary angle. There was no difference based on the number of bevels in the lancet. Rounded hub geometry had minimal distribution to the corneal epithelium. Conclusions: Needle characteristics impact the force needed for needle insertion into the tissue. Since higher force can lead to increased risk and less efficiency during the procedure, reducing this force may improve the outcomes of the procedure. Needle entry can be reduced by designing an improved needle that includes a lower gauge and reduced primary angle of the lancet.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.60
自引率
4.30%
发文量
72
审稿时长
1 months
期刊介绍: Journal of Ocular Pharmacology and Therapeutics is the only peer-reviewed journal that combines the fields of ophthalmology and pharmacology to enable optimal treatment and prevention of ocular diseases and disorders. The Journal delivers the latest discoveries in the pharmacokinetics and pharmacodynamics of therapeutics for the treatment of ophthalmic disorders. Journal of Ocular Pharmacology and Therapeutics coverage includes: Glaucoma Cataracts Retinal degeneration Ocular infection, trauma, and toxicology Ocular drug delivery and biotransformation Ocular pharmacotherapy/clinical trials Ocular inflammatory and immune disorders Gene and cell-based therapies Ocular metabolic disorders Ocular ischemia and blood flow Proliferative disorders of the eye Eyes on Drug Discovery - written by Gary D. Novack, PhD, featuring the latest updates on drug and device pipeline developments as well as policy/regulatory changes by the FDA.
期刊最新文献
Duration of Bare Sclera Pterygium Surgery Combined with Mitomycin C with and Without Tranexamic Acid: A Randomized Double-Blind Controlled Trial. Preclinical and Clinical Pharmacokinetics of a New Preservative-Free Bimatoprost 0.01% Ophthalmic Gel to Treat Glaucoma and Ocular Hypertension. Effects of Intense Pulsed Light on Presumed Neuropathic Pain Associated with Meibomian Gland Dysfunction: A Before-After Study. Eyes on New Product Development. Neuritin 1 Drives Therapeutic Preservation of Retinal Ganglion Cells in an Ex Vivo Human Glaucoma Model.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1