Matthew W Holt, Eric C Robinson, Nathan A Shlobin, Jacob T Hanson, Ismail Bozkurt
{"title":"改善运动功能的皮质内脑机接口:一项系统综述。","authors":"Matthew W Holt, Eric C Robinson, Nathan A Shlobin, Jacob T Hanson, Ismail Bozkurt","doi":"10.1515/revneuro-2023-0077","DOIUrl":null,"url":null,"abstract":"<p><p>In this systematic review, we address the status of intracortical brain-computer interfaces (iBCIs) applied to the motor cortex to improve function in patients with impaired motor ability. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 Guidelines for Systematic Reviews. Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) and the Effective Public Health Practice Project (EPHPP) were used to assess bias and quality. Advances in iBCIs in the last two decades demonstrated the use of iBCI to activate limbs for functional tasks, achieve neural typing for communication, and other applications. However, the inconsistency of performance metrics employed by these studies suggests the need for standardization. Each study was a pilot clinical trial consisting of 1-4, majority male (64.28 %) participants, with most trials featuring participants treated for more than 12 months (55.55 %). The systems treated patients with various conditions: amyotrophic lateral sclerosis, stroke, spinocerebellar degeneration without cerebellar involvement, and spinal cord injury. All participants presented with tetraplegia at implantation and were implanted with microelectrode arrays via pneumatic insertion, with nearly all electrode locations solely at the precentral gyrus of the motor cortex (88.88 %). The development of iBCI devices using neural signals from the motor cortex to improve motor-impaired patients has enhanced the ability of these systems to return ability to their users. However, many milestones remain before these devices can prove their feasibility for recovery. This review summarizes the achievements and shortfalls of these systems and their respective trials.</p>","PeriodicalId":49623,"journal":{"name":"Reviews in the Neurosciences","volume":" ","pages":"213-223"},"PeriodicalIF":3.4000,"publicationDate":"2023-10-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Intracortical brain-computer interfaces for improved motor function: a systematic review.\",\"authors\":\"Matthew W Holt, Eric C Robinson, Nathan A Shlobin, Jacob T Hanson, Ismail Bozkurt\",\"doi\":\"10.1515/revneuro-2023-0077\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In this systematic review, we address the status of intracortical brain-computer interfaces (iBCIs) applied to the motor cortex to improve function in patients with impaired motor ability. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 Guidelines for Systematic Reviews. Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) and the Effective Public Health Practice Project (EPHPP) were used to assess bias and quality. Advances in iBCIs in the last two decades demonstrated the use of iBCI to activate limbs for functional tasks, achieve neural typing for communication, and other applications. However, the inconsistency of performance metrics employed by these studies suggests the need for standardization. Each study was a pilot clinical trial consisting of 1-4, majority male (64.28 %) participants, with most trials featuring participants treated for more than 12 months (55.55 %). The systems treated patients with various conditions: amyotrophic lateral sclerosis, stroke, spinocerebellar degeneration without cerebellar involvement, and spinal cord injury. All participants presented with tetraplegia at implantation and were implanted with microelectrode arrays via pneumatic insertion, with nearly all electrode locations solely at the precentral gyrus of the motor cortex (88.88 %). The development of iBCI devices using neural signals from the motor cortex to improve motor-impaired patients has enhanced the ability of these systems to return ability to their users. However, many milestones remain before these devices can prove their feasibility for recovery. This review summarizes the achievements and shortfalls of these systems and their respective trials.</p>\",\"PeriodicalId\":49623,\"journal\":{\"name\":\"Reviews in the Neurosciences\",\"volume\":\" \",\"pages\":\"213-223\"},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2023-10-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Reviews in the Neurosciences\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"https://doi.org/10.1515/revneuro-2023-0077\",\"RegionNum\":3,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2024/2/26 0:00:00\",\"PubModel\":\"Print\",\"JCR\":\"Q2\",\"JCRName\":\"NEUROSCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Reviews in the Neurosciences","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1515/revneuro-2023-0077","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2024/2/26 0:00:00","PubModel":"Print","JCR":"Q2","JCRName":"NEUROSCIENCES","Score":null,"Total":0}
Intracortical brain-computer interfaces for improved motor function: a systematic review.
In this systematic review, we address the status of intracortical brain-computer interfaces (iBCIs) applied to the motor cortex to improve function in patients with impaired motor ability. This study followed the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) 2020 Guidelines for Systematic Reviews. Risk Of Bias In Non-randomized Studies - of Interventions (ROBINS-I) and the Effective Public Health Practice Project (EPHPP) were used to assess bias and quality. Advances in iBCIs in the last two decades demonstrated the use of iBCI to activate limbs for functional tasks, achieve neural typing for communication, and other applications. However, the inconsistency of performance metrics employed by these studies suggests the need for standardization. Each study was a pilot clinical trial consisting of 1-4, majority male (64.28 %) participants, with most trials featuring participants treated for more than 12 months (55.55 %). The systems treated patients with various conditions: amyotrophic lateral sclerosis, stroke, spinocerebellar degeneration without cerebellar involvement, and spinal cord injury. All participants presented with tetraplegia at implantation and were implanted with microelectrode arrays via pneumatic insertion, with nearly all electrode locations solely at the precentral gyrus of the motor cortex (88.88 %). The development of iBCI devices using neural signals from the motor cortex to improve motor-impaired patients has enhanced the ability of these systems to return ability to their users. However, many milestones remain before these devices can prove their feasibility for recovery. This review summarizes the achievements and shortfalls of these systems and their respective trials.
期刊介绍:
Reviews in the Neurosciences provides a forum for reviews, critical evaluations and theoretical treatment of selective topics in the neurosciences. The journal is meant to provide an authoritative reference work for those interested in the structure and functions of the nervous system at all levels of analysis, including the genetic, molecular, cellular, behavioral, cognitive and clinical neurosciences. Contributions should contain a critical appraisal of specific areas and not simply a compilation of published articles.