目前有限元模型的泊松比值太低,无法将软组织视为几乎不可压缩的:人类足跟区域的插图。

IF 1.7 4区 医学 Q3 COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS Computer Methods in Biomechanics and Biomedical Engineering Pub Date : 2024-11-01 Epub Date: 2023-10-17 DOI:10.1080/10255842.2023.2269286
Nolwenn Fougeron, Alessio Trebbi, Bethany Keenan, Yohan Payan, Gregory Chagnon
{"title":"目前有限元模型的泊松比值太低,无法将软组织视为几乎不可压缩的:人类足跟区域的插图。","authors":"Nolwenn Fougeron, Alessio Trebbi, Bethany Keenan, Yohan Payan, Gregory Chagnon","doi":"10.1080/10255842.2023.2269286","DOIUrl":null,"url":null,"abstract":"<p><p>Tissues' nearly incompressibility was well reported in the literature but little effort has been made to compare volume variations computed by simulations with <i>in vivo</i> measurements. In this study, volume changes of the fat pad during controlled indentations of the human heel region were estimated from segmented medical images using digital volume correlation. The experiment was reproduced using finite element modelling with several values of Poisson's ratio for the fat pad, from 0.4500 to 0.4999. A single value of Poisson's ratio could not fit all the indentation cases. Estimated volume changes were between 0.9% - 11.7%.</p>","PeriodicalId":50640,"journal":{"name":"Computer Methods in Biomechanics and Biomedical Engineering","volume":null,"pages":null},"PeriodicalIF":1.7000,"publicationDate":"2024-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Current poisson's ratio values of finite element models are too low to consider soft tissues nearly-incompressible: illustration on the human heel region.\",\"authors\":\"Nolwenn Fougeron, Alessio Trebbi, Bethany Keenan, Yohan Payan, Gregory Chagnon\",\"doi\":\"10.1080/10255842.2023.2269286\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Tissues' nearly incompressibility was well reported in the literature but little effort has been made to compare volume variations computed by simulations with <i>in vivo</i> measurements. In this study, volume changes of the fat pad during controlled indentations of the human heel region were estimated from segmented medical images using digital volume correlation. The experiment was reproduced using finite element modelling with several values of Poisson's ratio for the fat pad, from 0.4500 to 0.4999. A single value of Poisson's ratio could not fit all the indentation cases. Estimated volume changes were between 0.9% - 11.7%.</p>\",\"PeriodicalId\":50640,\"journal\":{\"name\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.7000,\"publicationDate\":\"2024-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computer Methods in Biomechanics and Biomedical Engineering\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1080/10255842.2023.2269286\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/10/17 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q3\",\"JCRName\":\"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computer Methods in Biomechanics and Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1080/10255842.2023.2269286","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/10/17 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"COMPUTER SCIENCE, INTERDISCIPLINARY APPLICATIONS","Score":null,"Total":0}
引用次数: 0

摘要

文献中充分报道了组织的几乎不可压缩性,但很少将模拟计算的体积变化与体内测量进行比较。在这项研究中,使用数字体积相关性从分割的医学图像中估计了人类足跟区域受控压痕期间脂肪垫的体积变化。使用有限元建模重现了该实验,脂肪垫的泊松比有几个值,从0.4500到0.4999。泊松比的单一值不能适用于所有压痕情况。预计体积变化在0.9%至11.7%之间。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Current poisson's ratio values of finite element models are too low to consider soft tissues nearly-incompressible: illustration on the human heel region.

Tissues' nearly incompressibility was well reported in the literature but little effort has been made to compare volume variations computed by simulations with in vivo measurements. In this study, volume changes of the fat pad during controlled indentations of the human heel region were estimated from segmented medical images using digital volume correlation. The experiment was reproduced using finite element modelling with several values of Poisson's ratio for the fat pad, from 0.4500 to 0.4999. A single value of Poisson's ratio could not fit all the indentation cases. Estimated volume changes were between 0.9% - 11.7%.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
4.10
自引率
6.20%
发文量
179
审稿时长
4-8 weeks
期刊介绍: The primary aims of Computer Methods in Biomechanics and Biomedical Engineering are to provide a means of communicating the advances being made in the areas of biomechanics and biomedical engineering and to stimulate interest in the continually emerging computer based technologies which are being applied in these multidisciplinary subjects. Computer Methods in Biomechanics and Biomedical Engineering will also provide a focus for the importance of integrating the disciplines of engineering with medical technology and clinical expertise. Such integration will have a major impact on health care in the future.
期刊最新文献
Accurate detection of gait events using neural networks and IMU data mimicking real-world smartphone usage. Exploring coronavirus sequence motifs through convolutional neural network for accurate identification of COVID-19. Coexistence of horizontal bone loss and dehiscence with the bundle and conventional fiber post: a finite element analysis. Effects of a soft back exoskeleton on lower lumbar spine loads during manual materials handling: a musculoskeletal modelling study. Mechanical effect of taper position in abutment hole and screw taper angles on implant system and peri-implant tissue: a finite element analysis.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1