使用导针器弯曲30号针头:疲劳寿命评估。

Jared Joseph Tuttle, Andrew Doran Davidson, Gregory Kent Tuttle
{"title":"使用导针器弯曲30号针头:疲劳寿命评估。","authors":"Jared Joseph Tuttle,&nbsp;Andrew Doran Davidson,&nbsp;Gregory Kent Tuttle","doi":"10.17245/jdapm.2023.23.5.281","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Dentists bend needles prior to certain injections; however, there are concerns regarding needle fracture, lumen occlusion, and sharps handling. A previous study found that a 30-gauge needle fractures after four to nine 90° bends. This fatigue life study evaluated how many 90° bends a 30-gauge dental needle will sustain before fracture when bent using a needle guide.</p><p><strong>Methods: </strong>Two operators at Element Materials Technology, an independent testing, inspection, and certification company tested 48 30-gauge needles. After applying the needle guide, the operators bent the needle to a 90° angle and expressed the anesthetic from the tip. The needle was then bent back to a 0° angle, and the functionality was tested again. This process was repeated until the anesthetic failed to pass through the end of the needle due to fracture or obstruction. Each operator tested 24 needles (12 needles from each lot), and the number of sustained bends before the needle fracture was recorded.</p><p><strong>Results: </strong>The average number of sustained bends before needle failure was 40.33 (95% confidence interval = 37.41-43.26), with a minimum of 20, median of 40, and a maximum of 54. In each trial, the lumen remained patent until the needle fractured. The difference between the operators was statistically significant (P < 0.001). No significant differences in performance between needle lots were observed (P = 0.504).</p><p><strong>Conclusion: </strong>Our results suggest that using a needle guide increases the number of sustained bends before needle fracture (P < 0.000001) than those reported in previous studies. Future studies should further evaluate the use of needle guides with other needle types across a variety of operators. Furthermore, additional opportunities lie in exploring workplace safety considerations and clinical applications of anesthetic delivery using a bent needle.</p>","PeriodicalId":94330,"journal":{"name":"Journal of dental anesthesia and pain medicine","volume":"23 5","pages":"281-285"},"PeriodicalIF":0.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a4/43/jdapm-23-281.PMC10567543.pdf","citationCount":"0","resultStr":"{\"title\":\"Bending 30-gauge needles using a needle guide: fatigue life evaluation.\",\"authors\":\"Jared Joseph Tuttle,&nbsp;Andrew Doran Davidson,&nbsp;Gregory Kent Tuttle\",\"doi\":\"10.17245/jdapm.2023.23.5.281\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Dentists bend needles prior to certain injections; however, there are concerns regarding needle fracture, lumen occlusion, and sharps handling. A previous study found that a 30-gauge needle fractures after four to nine 90° bends. This fatigue life study evaluated how many 90° bends a 30-gauge dental needle will sustain before fracture when bent using a needle guide.</p><p><strong>Methods: </strong>Two operators at Element Materials Technology, an independent testing, inspection, and certification company tested 48 30-gauge needles. After applying the needle guide, the operators bent the needle to a 90° angle and expressed the anesthetic from the tip. The needle was then bent back to a 0° angle, and the functionality was tested again. This process was repeated until the anesthetic failed to pass through the end of the needle due to fracture or obstruction. Each operator tested 24 needles (12 needles from each lot), and the number of sustained bends before the needle fracture was recorded.</p><p><strong>Results: </strong>The average number of sustained bends before needle failure was 40.33 (95% confidence interval = 37.41-43.26), with a minimum of 20, median of 40, and a maximum of 54. In each trial, the lumen remained patent until the needle fractured. The difference between the operators was statistically significant (P < 0.001). No significant differences in performance between needle lots were observed (P = 0.504).</p><p><strong>Conclusion: </strong>Our results suggest that using a needle guide increases the number of sustained bends before needle fracture (P < 0.000001) than those reported in previous studies. Future studies should further evaluate the use of needle guides with other needle types across a variety of operators. Furthermore, additional opportunities lie in exploring workplace safety considerations and clinical applications of anesthetic delivery using a bent needle.</p>\",\"PeriodicalId\":94330,\"journal\":{\"name\":\"Journal of dental anesthesia and pain medicine\",\"volume\":\"23 5\",\"pages\":\"281-285\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://ftp.ncbi.nlm.nih.gov/pub/pmc/oa_pdf/a4/43/jdapm-23-281.PMC10567543.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of dental anesthesia and pain medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17245/jdapm.2023.23.5.281\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/9/27 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental anesthesia and pain medicine","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17245/jdapm.2023.23.5.281","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/9/27 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

背景:牙医在注射前会弯曲针头;然而,也存在针断裂、管腔堵塞和锐器处理方面的问题。之前的一项研究发现,30号针头在弯曲四到九个90°后会骨折。这项疲劳寿命研究评估了当使用导针器弯曲时,30号牙针在骨折前能承受多少90°弯曲。方法:独立测试、检验和认证公司Element Materials Technology的两名操作员测试了48根30号针头。使用导针器后,操作人员将针头弯曲成90°角,并从尖端表达麻醉剂。然后将针头向后弯曲至0°角,并再次测试功能。重复这个过程,直到麻醉剂由于骨折或阻塞而无法通过针头末端。每位操作员测试了24根针头(每批12根),并记录针头断裂前持续弯曲的次数。结果:针刺失败前持续弯曲的平均次数为40.33次(95%置信区间=37.41-43.26),最小为20次,中位数为40次,最大为54次。在每次试验中,管腔都保持通畅,直到针头断裂。操作者之间的差异具有统计学意义(P<0.001)。不同针组之间的性能没有观察到显著差异(P=0.504)。结论:我们的结果表明,与先前研究中报道的相比,使用导针器可增加骨折前持续弯曲的次数(P<0.000001)。未来的研究应进一步评估各种操作员将导针器与其他类型的针头一起使用的情况。此外,更多的机会在于探索工作场所安全考虑因素和使用弯针进行麻醉剂输送的临床应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

摘要图片

摘要图片

摘要图片

查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Bending 30-gauge needles using a needle guide: fatigue life evaluation.

Background: Dentists bend needles prior to certain injections; however, there are concerns regarding needle fracture, lumen occlusion, and sharps handling. A previous study found that a 30-gauge needle fractures after four to nine 90° bends. This fatigue life study evaluated how many 90° bends a 30-gauge dental needle will sustain before fracture when bent using a needle guide.

Methods: Two operators at Element Materials Technology, an independent testing, inspection, and certification company tested 48 30-gauge needles. After applying the needle guide, the operators bent the needle to a 90° angle and expressed the anesthetic from the tip. The needle was then bent back to a 0° angle, and the functionality was tested again. This process was repeated until the anesthetic failed to pass through the end of the needle due to fracture or obstruction. Each operator tested 24 needles (12 needles from each lot), and the number of sustained bends before the needle fracture was recorded.

Results: The average number of sustained bends before needle failure was 40.33 (95% confidence interval = 37.41-43.26), with a minimum of 20, median of 40, and a maximum of 54. In each trial, the lumen remained patent until the needle fractured. The difference between the operators was statistically significant (P < 0.001). No significant differences in performance between needle lots were observed (P = 0.504).

Conclusion: Our results suggest that using a needle guide increases the number of sustained bends before needle fracture (P < 0.000001) than those reported in previous studies. Future studies should further evaluate the use of needle guides with other needle types across a variety of operators. Furthermore, additional opportunities lie in exploring workplace safety considerations and clinical applications of anesthetic delivery using a bent needle.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Analgesic efficiency of dexketoprofen trometamol in third molar surgery: a systematic review and meta-analysis. Assessment of the effect of premedication on the success of inferior alveolar nerve block in tobacco chewing patients with symptomatic irreversible pulpitis: a randomized control trial. Cuff tear of endotracheal tube induced by a palatal orthodontic device during nasotracheal intubation: a case report. Eye movement desensitization and reprocessing therapy as an adjunct to pain management during dental extraction in children - a randomized control trial. Photobiomodulation by soft laser irradiation with and without ibuprofen improves success rate of inferior alveolar nerve block using 2% lignocaine with adrenaline in symptomatic irreversible pulpitis of mandibular molar teeth: a double-blind, randomized placebo-controlled trial.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1