{"title":"基于ATMega16A PU单片机的抑郁症测量工具系统","authors":"Muhammad Mispu Ariadi, I. Sugriwan, A. Fahrudin","doi":"10.20527/flux.v1i1.6154","DOIUrl":null,"url":null,"abstract":"The fabrication of the ATMega16A-PU microcontroller-based the system turbidity sensor consists of sensor module Turbidity SKU:SEN0189 including with the signal conditioning, power supply unit, the ATMega16A-PU microcontroller module, LCD 16 x 2 character, and personal computer (PC). The measuring system is used to measure the quality of water on theriverMartapura South Kalimantan, Indonesia. The physical parameters that measured is the of water. The measuring of turbidity detected by the sensor through the light that traverse the suspended particles in water. The output signal from the sensor in from of the voltage signal is connectedwith ATMega16A-PU microcontroller viaport A0. The voltage signal output is inversely proportional to the turbidity. Theequation of sensor characteristic is obtained by comparing the measuring device with HACH DR 890 Colorimeter turbid meter gauge. The characteristic equation obtained is counted into five equations to get a small error value, where v1 = -0.0036k1 + 4.0834, v2 = -0.0024k2 + 3.9351, v3 = -0.003k3 + 4.1777, v4 = -0.0033k4 + 4.3355, v5 = -0.0034k5 + 4.4315, the five equations have different measurement ranges. The result of data measurement are displayed on the LCD 16 x 2 character and the personal computer (PC) with the Delphi.7 interface program. The advantages of personal computer (PC) interface are the data measurement result could monitor and stroge in excel and database format. The results of the measuring instrument show a difference of 1 NTU to 15 NTU with the largest deviation is ± 28.7 and a standard deviation of ± 4.57 in the range of 31 NTU to 510 NTU","PeriodicalId":34112,"journal":{"name":"Jurnal Fisika Flux","volume":"1 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2019-01-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"Sistem Alat Ukur Kekeruhan Berbasis Mikrokontroler ATMega16A-PU\",\"authors\":\"Muhammad Mispu Ariadi, I. Sugriwan, A. Fahrudin\",\"doi\":\"10.20527/flux.v1i1.6154\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The fabrication of the ATMega16A-PU microcontroller-based the system turbidity sensor consists of sensor module Turbidity SKU:SEN0189 including with the signal conditioning, power supply unit, the ATMega16A-PU microcontroller module, LCD 16 x 2 character, and personal computer (PC). The measuring system is used to measure the quality of water on theriverMartapura South Kalimantan, Indonesia. The physical parameters that measured is the of water. The measuring of turbidity detected by the sensor through the light that traverse the suspended particles in water. The output signal from the sensor in from of the voltage signal is connectedwith ATMega16A-PU microcontroller viaport A0. The voltage signal output is inversely proportional to the turbidity. Theequation of sensor characteristic is obtained by comparing the measuring device with HACH DR 890 Colorimeter turbid meter gauge. The characteristic equation obtained is counted into five equations to get a small error value, where v1 = -0.0036k1 + 4.0834, v2 = -0.0024k2 + 3.9351, v3 = -0.003k3 + 4.1777, v4 = -0.0033k4 + 4.3355, v5 = -0.0034k5 + 4.4315, the five equations have different measurement ranges. The result of data measurement are displayed on the LCD 16 x 2 character and the personal computer (PC) with the Delphi.7 interface program. The advantages of personal computer (PC) interface are the data measurement result could monitor and stroge in excel and database format. The results of the measuring instrument show a difference of 1 NTU to 15 NTU with the largest deviation is ± 28.7 and a standard deviation of ± 4.57 in the range of 31 NTU to 510 NTU\",\"PeriodicalId\":34112,\"journal\":{\"name\":\"Jurnal Fisika Flux\",\"volume\":\"1 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2019-01-26\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Jurnal Fisika Flux\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.20527/flux.v1i1.6154\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Jurnal Fisika Flux","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.20527/flux.v1i1.6154","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1
摘要
基于系统浊度传感器的ATMega16A PU微控制器的制造包括传感器模块浊度SKU:SEN0189,包括信号调节、电源单元、ATMega16PU微控制器模块、LCD 16 x 2字符和个人电脑(PC)。该测量系统用于测量印度尼西亚南加里曼丹马尔塔普拉的水质。测量的物理参数是水的。传感器通过穿过水中悬浮颗粒的光来测量浊度。电压信号的传感器输入的输出信号通过端口A0与ATMega16A PU微控制器相连。电压信号输出与浊度成反比。通过与HACH DR 890色度计浊度计的比较,得出了传感器特性方程。将得到的特征方程计算为五个方程,得到一个小的误差值,其中v1=-0.0036k1+4.0834,v2=-0.0024k2+3.9351,v3=-0.003k3+4.1777,v4=-0.0033k4+4.3355,v5=-0.0034k5+4.4315,五个方程具有不同的测量范围。数据测量结果用Delphi.7接口程序显示在16x2字符的液晶显示器和个人电脑上。个人计算机(PC)接口的优点是数据测量结果可以用excel和数据库格式进行监测和存储。测量仪器的结果显示,差异为1 NTU至15 NTU,最大偏差为±28.7,标准偏差为±4.57,范围为31 NTU至510 NTU
Sistem Alat Ukur Kekeruhan Berbasis Mikrokontroler ATMega16A-PU
The fabrication of the ATMega16A-PU microcontroller-based the system turbidity sensor consists of sensor module Turbidity SKU:SEN0189 including with the signal conditioning, power supply unit, the ATMega16A-PU microcontroller module, LCD 16 x 2 character, and personal computer (PC). The measuring system is used to measure the quality of water on theriverMartapura South Kalimantan, Indonesia. The physical parameters that measured is the of water. The measuring of turbidity detected by the sensor through the light that traverse the suspended particles in water. The output signal from the sensor in from of the voltage signal is connectedwith ATMega16A-PU microcontroller viaport A0. The voltage signal output is inversely proportional to the turbidity. Theequation of sensor characteristic is obtained by comparing the measuring device with HACH DR 890 Colorimeter turbid meter gauge. The characteristic equation obtained is counted into five equations to get a small error value, where v1 = -0.0036k1 + 4.0834, v2 = -0.0024k2 + 3.9351, v3 = -0.003k3 + 4.1777, v4 = -0.0033k4 + 4.3355, v5 = -0.0034k5 + 4.4315, the five equations have different measurement ranges. The result of data measurement are displayed on the LCD 16 x 2 character and the personal computer (PC) with the Delphi.7 interface program. The advantages of personal computer (PC) interface are the data measurement result could monitor and stroge in excel and database format. The results of the measuring instrument show a difference of 1 NTU to 15 NTU with the largest deviation is ± 28.7 and a standard deviation of ± 4.57 in the range of 31 NTU to 510 NTU