麻醉医师和其他人员同时进行PET/MRI的辐射安全:患者在进行长时间扫描时可能受到的辐射照射

IF 0.2 Q4 ANESTHESIOLOGY Journal of Neuroanaesthesiology and Critical Care Pub Date : 2022-09-01 DOI:10.1055/s-0042-1750710
C. Nagaraj, R. Joshi, Dinesh G. Kumar, G. R, D. Chakrabarti, P. Singh, Sandhya Mangalore, Ramesh J. Venkatapura
{"title":"麻醉医师和其他人员同时进行PET/MRI的辐射安全:患者在进行长时间扫描时可能受到的辐射照射","authors":"C. Nagaraj, R. Joshi, Dinesh G. Kumar, G. R, D. Chakrabarti, P. Singh, Sandhya Mangalore, Ramesh J. Venkatapura","doi":"10.1055/s-0042-1750710","DOIUrl":null,"url":null,"abstract":"Abstract This observational study was conducted owing to the challenges of the positron emission tomography/magnetic resonance imaging (PET/MRI) that requires longer duration scanning of radiopharmaceutical injected patient and added MRI environment. The aim of this study was to assess radiation dose at different distances from the patient and the radiation burden to anesthesiologist and other personnel in performing PET/MRI under general anesthesia or sedation. First, the pre- and postscan whole body radiation exposure (WBE) from the patient were obtained for 45 minutes ( n  = 109) after injection of the radiopharmaceutical. The WBE was obtained at specific distances from brain (10, 30, and 100 cm) and abdomen (10 and 30cm) of patients undergoing F18 fluorodeoxyglucose PET/MRI brain or whole body studies. Second, WBE of the anesthesiologist and other staff working was separately measured using pocket dosimeters during the whole procedure. In brain scans, the mean absorbed dose rates (ADR) of prescan (45 minutes) and postscan (45 minutes) were 44.4 and 31.1 μSv at 10 cm, 14.9 and 9.7μSv at 30 cm, and 3.5 and 2.8 μSv at 100 cm, respectively, from surface of head. Similarly, it was 54.8 and 30.3 μSv at 10 cm, 23 and 13.6μSv at 30 cm, respectively, from surface of abdomen. In WB scans, the mean ADR was higher than the brain scans. Anesthesiologist exposure overall was found to be 4.84 µSv/patient/scan (112 patients). The anesthesiologist receives a safe mean effective dose in PET/MRI scanning. With good training and adequate planning, it is possible to decrease the radiation exposure to all the concerned personnel including anesthesiologists.","PeriodicalId":16574,"journal":{"name":"Journal of Neuroanaesthesiology and Critical Care","volume":null,"pages":null},"PeriodicalIF":0.2000,"publicationDate":"2022-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Radiation Safety for Anesthesiologists and Other Personnel on Simultaneous PET/MRI: Possible Radiation Exposure from Patients While Performing Prolonged Duration Scans\",\"authors\":\"C. Nagaraj, R. Joshi, Dinesh G. Kumar, G. R, D. Chakrabarti, P. Singh, Sandhya Mangalore, Ramesh J. Venkatapura\",\"doi\":\"10.1055/s-0042-1750710\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract This observational study was conducted owing to the challenges of the positron emission tomography/magnetic resonance imaging (PET/MRI) that requires longer duration scanning of radiopharmaceutical injected patient and added MRI environment. The aim of this study was to assess radiation dose at different distances from the patient and the radiation burden to anesthesiologist and other personnel in performing PET/MRI under general anesthesia or sedation. First, the pre- and postscan whole body radiation exposure (WBE) from the patient were obtained for 45 minutes ( n  = 109) after injection of the radiopharmaceutical. The WBE was obtained at specific distances from brain (10, 30, and 100 cm) and abdomen (10 and 30cm) of patients undergoing F18 fluorodeoxyglucose PET/MRI brain or whole body studies. Second, WBE of the anesthesiologist and other staff working was separately measured using pocket dosimeters during the whole procedure. In brain scans, the mean absorbed dose rates (ADR) of prescan (45 minutes) and postscan (45 minutes) were 44.4 and 31.1 μSv at 10 cm, 14.9 and 9.7μSv at 30 cm, and 3.5 and 2.8 μSv at 100 cm, respectively, from surface of head. Similarly, it was 54.8 and 30.3 μSv at 10 cm, 23 and 13.6μSv at 30 cm, respectively, from surface of abdomen. In WB scans, the mean ADR was higher than the brain scans. Anesthesiologist exposure overall was found to be 4.84 µSv/patient/scan (112 patients). The anesthesiologist receives a safe mean effective dose in PET/MRI scanning. With good training and adequate planning, it is possible to decrease the radiation exposure to all the concerned personnel including anesthesiologists.\",\"PeriodicalId\":16574,\"journal\":{\"name\":\"Journal of Neuroanaesthesiology and Critical Care\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2022-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Neuroanaesthesiology and Critical Care\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1055/s-0042-1750710\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"ANESTHESIOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Neuroanaesthesiology and Critical Care","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1055/s-0042-1750710","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

摘要

摘要本观察性研究是由于正电子发射断层扫描/磁共振成像(PET/MRI)的挑战而进行的,这需要对注射放射性药物的患者进行更长时间的扫描,并增加MRI环境。本研究的目的是评估在全身麻醉或镇静下进行PET/MRI时,与患者不同距离的辐射剂量以及麻醉师和其他人员的辐射负担。首先,对45名患者进行扫描前和扫描后全身辐射暴露(WBE) 分钟(n = 109)。WBE是在距离大脑特定距离(10、30和100 cm)和腹部(10和30cm)。其次,在整个过程中,麻醉师和其他工作人员的WBE分别使用袖珍剂量计进行测量。在脑部扫描中,处方药(45 分钟)和后扫描(45 分钟)分别为44.4和31.1 30时分别为14.9和9.7μSv cm,100时为3.5和2.8μSv 距头部表面分别为厘米。同样,在10 cm、23和13.6μSv 距腹部表面分别为厘米。在WB扫描中,平均ADR高于脑部扫描。麻醉师的总体暴露量为4.84µSv/患者/扫描(112名患者)。麻醉师在PET/MRI扫描中接受安全平均有效剂量。通过良好的培训和充分的计划,可以减少包括麻醉师在内的所有相关人员的辐射暴露。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Radiation Safety for Anesthesiologists and Other Personnel on Simultaneous PET/MRI: Possible Radiation Exposure from Patients While Performing Prolonged Duration Scans
Abstract This observational study was conducted owing to the challenges of the positron emission tomography/magnetic resonance imaging (PET/MRI) that requires longer duration scanning of radiopharmaceutical injected patient and added MRI environment. The aim of this study was to assess radiation dose at different distances from the patient and the radiation burden to anesthesiologist and other personnel in performing PET/MRI under general anesthesia or sedation. First, the pre- and postscan whole body radiation exposure (WBE) from the patient were obtained for 45 minutes ( n  = 109) after injection of the radiopharmaceutical. The WBE was obtained at specific distances from brain (10, 30, and 100 cm) and abdomen (10 and 30cm) of patients undergoing F18 fluorodeoxyglucose PET/MRI brain or whole body studies. Second, WBE of the anesthesiologist and other staff working was separately measured using pocket dosimeters during the whole procedure. In brain scans, the mean absorbed dose rates (ADR) of prescan (45 minutes) and postscan (45 minutes) were 44.4 and 31.1 μSv at 10 cm, 14.9 and 9.7μSv at 30 cm, and 3.5 and 2.8 μSv at 100 cm, respectively, from surface of head. Similarly, it was 54.8 and 30.3 μSv at 10 cm, 23 and 13.6μSv at 30 cm, respectively, from surface of abdomen. In WB scans, the mean ADR was higher than the brain scans. Anesthesiologist exposure overall was found to be 4.84 µSv/patient/scan (112 patients). The anesthesiologist receives a safe mean effective dose in PET/MRI scanning. With good training and adequate planning, it is possible to decrease the radiation exposure to all the concerned personnel including anesthesiologists.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Neuroanaesthesiology and Critical Care
Journal of Neuroanaesthesiology and Critical Care Medicine-Critical Care and Intensive Care Medicine
CiteScore
0.50
自引率
0.00%
发文量
29
审稿时长
15 weeks
期刊最新文献
Anesthetic Challenges in Hirayama Disease Patients Undergoing Cervical Spine Surgery—A Case Series Management and Outcomes of Delayed Cerebral Ischemia Associated with Vasospasm Post Nontraumatic Subarachnoid Hemorrhage: A Retrospective Cohort Study in the National Neurosurgical Center in Ireland Chronic Epidural Hematoma in an Elderly Patient: A Rare Encounter!! The Emerging Role of Transnasal Humidified Rapid-Insufflation Ventilatory Exchange (THRIVE) Technique and C-MAC Videolaryngoscope for Difficult Airway Management in a Patient with Klippel–Feil Syndrome: A Case Report Intense Noxious Stimulus during an Adequate Depth of General Anesthesia Produces a Transient Burst Suppression Pattern in a Density Spectral Array
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1