颌骨跟踪技术在体积调制弧线治疗中对靶侧化患者样本的剂量评估

IF 0.3 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Radiotherapy in Practice Pub Date : 2023-02-15 DOI:10.1017/S1460396923000031
Rogelio Manuel Diaz Moreno, M. Almada, Albin Ariel García Andino, C. Venencia
{"title":"颌骨跟踪技术在体积调制弧线治疗中对靶侧化患者样本的剂量评估","authors":"Rogelio Manuel Diaz Moreno, M. Almada, Albin Ariel García Andino, C. Venencia","doi":"10.1017/S1460396923000031","DOIUrl":null,"url":null,"abstract":"Abstract Introduction: In modulated radiotherapy treatments with the jaw tracking technique (JTT), the collimator jaws can dynamically follow the multileaf collimator apertures and reduce radiation leakage. This reduction protects normal tissue from unwanted doses. Previous research has highlighted the importance of defining which patients will benefit most from JTT. Besides, some authors have expressed their concerns about possible increases in monitor units (MUs). Treatments of patients with peripheral targets and isocentre located in the patient’s midline are of particular interest. The current work assessed the effect of JTT on these cases. Methods: JTT plans for thirty-two patients were compared to plans with the static jaws technique. The volumes of normal tissue receiving 5 Gy (V5), 10 Gy (V10) and 20 Gy (V20), mean dose (Dmean), target coverage parameters D95, D2% and Paddick’s conformity index (PCI) were compared. MUs were also registered for comparisons. The decrease in the jaws opening with JTT was correlated to the decrease in dose values in normal tissue. Results: Small decreases were observed in D95 and in D2% values, without statistical significance. A 5% average decrease in PCI values was noticed as well as significant decreases in V5, V10 and Dmean values, 9% on average. A 3% decrease in V20 was also observed. The number of MUs decreased by 2%. A significant correlation was found between the reduction of the secondary collimation opening areas and the dose delivered to normal tissue. Conclusions: JTT technique improved normal tissue protection in volumetric modulated arc therapy treatments for the patients included in the present study.","PeriodicalId":44597,"journal":{"name":"Journal of Radiotherapy in Practice","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2023-02-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Dosimetrical assessment of jaw tracking technique in volumetric modulated arc therapy for a sample of patients with lateralised targets\",\"authors\":\"Rogelio Manuel Diaz Moreno, M. Almada, Albin Ariel García Andino, C. Venencia\",\"doi\":\"10.1017/S1460396923000031\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Introduction: In modulated radiotherapy treatments with the jaw tracking technique (JTT), the collimator jaws can dynamically follow the multileaf collimator apertures and reduce radiation leakage. This reduction protects normal tissue from unwanted doses. Previous research has highlighted the importance of defining which patients will benefit most from JTT. Besides, some authors have expressed their concerns about possible increases in monitor units (MUs). Treatments of patients with peripheral targets and isocentre located in the patient’s midline are of particular interest. The current work assessed the effect of JTT on these cases. Methods: JTT plans for thirty-two patients were compared to plans with the static jaws technique. The volumes of normal tissue receiving 5 Gy (V5), 10 Gy (V10) and 20 Gy (V20), mean dose (Dmean), target coverage parameters D95, D2% and Paddick’s conformity index (PCI) were compared. MUs were also registered for comparisons. The decrease in the jaws opening with JTT was correlated to the decrease in dose values in normal tissue. Results: Small decreases were observed in D95 and in D2% values, without statistical significance. A 5% average decrease in PCI values was noticed as well as significant decreases in V5, V10 and Dmean values, 9% on average. A 3% decrease in V20 was also observed. The number of MUs decreased by 2%. A significant correlation was found between the reduction of the secondary collimation opening areas and the dose delivered to normal tissue. Conclusions: JTT technique improved normal tissue protection in volumetric modulated arc therapy treatments for the patients included in the present study.\",\"PeriodicalId\":44597,\"journal\":{\"name\":\"Journal of Radiotherapy in Practice\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2023-02-15\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiotherapy in Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/S1460396923000031\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiotherapy in Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/S1460396923000031","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

摘要简介:在JTT调制放射治疗中,准直器颌骨可以动态跟踪多叶准直器孔径,减少辐射泄漏。这种减少保护正常组织免受不必要的剂量。先前的研究强调了确定哪些患者将从JTT中获益最多的重要性。此外,一些作者对监测单位(mu)可能增加表示担忧。外周靶和等中心位于患者中线的患者的治疗是特别感兴趣的。目前的工作评估了JTT对这些病例的影响。方法:将32例患者的JTT计划与静颌技术计划进行比较。比较正常组织接受5 Gy (V5)、10 Gy (V10)、20 Gy (V20)的体积、平均剂量(Dmean)、靶覆盖参数D95、D2%和Paddick’s符合性指数(PCI)。MUs也被登记用于比较。JTT使颌骨开口减小与正常组织中剂量值的减小有关。结果:D95、d2值均有小幅下降,但无统计学意义。PCI值平均下降5%,V5、V10和Dmean值平均显著下降9%。V20也下降了3%。MUs的数量减少了2%。发现二次准直开口面积的减小与正常组织的剂量有显著的相关性。结论:JTT技术在体积调节电弧治疗中改善了对正常组织的保护。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dosimetrical assessment of jaw tracking technique in volumetric modulated arc therapy for a sample of patients with lateralised targets
Abstract Introduction: In modulated radiotherapy treatments with the jaw tracking technique (JTT), the collimator jaws can dynamically follow the multileaf collimator apertures and reduce radiation leakage. This reduction protects normal tissue from unwanted doses. Previous research has highlighted the importance of defining which patients will benefit most from JTT. Besides, some authors have expressed their concerns about possible increases in monitor units (MUs). Treatments of patients with peripheral targets and isocentre located in the patient’s midline are of particular interest. The current work assessed the effect of JTT on these cases. Methods: JTT plans for thirty-two patients were compared to plans with the static jaws technique. The volumes of normal tissue receiving 5 Gy (V5), 10 Gy (V10) and 20 Gy (V20), mean dose (Dmean), target coverage parameters D95, D2% and Paddick’s conformity index (PCI) were compared. MUs were also registered for comparisons. The decrease in the jaws opening with JTT was correlated to the decrease in dose values in normal tissue. Results: Small decreases were observed in D95 and in D2% values, without statistical significance. A 5% average decrease in PCI values was noticed as well as significant decreases in V5, V10 and Dmean values, 9% on average. A 3% decrease in V20 was also observed. The number of MUs decreased by 2%. A significant correlation was found between the reduction of the secondary collimation opening areas and the dose delivered to normal tissue. Conclusions: JTT technique improved normal tissue protection in volumetric modulated arc therapy treatments for the patients included in the present study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Radiotherapy in Practice
Journal of Radiotherapy in Practice RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
0.80
自引率
0.00%
发文量
36
期刊介绍: Journal of Radiotherapy in Practice is a peer-reviewed journal covering all of the current modalities specific to clinical oncology and radiotherapy. The journal aims to publish research from a wide range of styles and encourage debate and the exchange of information and opinion from within the field of radiotherapy practice and clinical oncology. The journal also aims to encourage technical evaluations and case studies as well as equipment reviews that will be of interest to an international radiotherapy audience.
期刊最新文献
Wobbling nature of gamma passing rate as a function of calibration field sizes in patient-specific quality assurance Secondary fragmentation and relative biological effectiveness (RBE) study using Bridge SOI microdosimeter: Monte Carlo simulation Keratin-based topical cream for radiation dermatitis during head and neck radiotherapy: a randomised, open-label pilot study. Single catheter 3d volume based hybrid inverse planning optimization in IVBT can improve organ sparing – CORRIGENDUM Dosimetric case study of 3-D FiF vs. VMAT techniques in the treatment of H/N tumour
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1