改良电位计传感器测定AVELOX药物制剂中盐酸莫西沙星的含量

IF 1.1 4区 工程技术 Q4 POLYMER SCIENCE Polimery Pub Date : 2021-12-25 DOI:10.14314/polimery.2021.11.4
Sachin Kumar, Sushil K. Sindhu, Praveen Kumar, A. Sharma, S. Sagadevan
{"title":"改良电位计传感器测定AVELOX药物制剂中盐酸莫西沙星的含量","authors":"Sachin Kumar, Sushil K. Sindhu, Praveen Kumar, A. Sharma, S. Sagadevan","doi":"10.14314/polimery.2021.11.4","DOIUrl":null,"url":null,"abstract":"Three different carbon paste (CP), silk-screen (SP) and poly (vinyl chloride) (PVC) modified electrodes were obtained to verify the reliability of AVELOX, the generic name of which is Moxifloxacin HCl (AV-MOXH). The sensing membranes were containing AVELOX ion associated complexes with sodium tetraphenylborate (NaTPB), phosphomolybdic acid (PMA), phosphotungstic acid (PTA), and ammonium reineckate (RN) as electroactive materials. All three electrodes gave fast, viable, and near-Nernstian linear responses over a relative wide concentration range that ranged from 1.010-6 to 1.010-2 mol / L AV-MOXH at 25° C with a monovalent cationic decrease. The sensors demonstrated a good discernment of AV-MOXH from numerous inorganic and organic compounds such as glucose, sucrose, Na+, Ca+, etc. Additionally, the isothermal coefficients along with selectivity coefficients were calculated. The modified Screen Printed Electrode sensor appeared to be highly sensitive for the determination of AV-MOXH. The electrode response was observed in pH range 2--6 for ISPE electrodes and IPVC electrodes and 3--7 for ICPE electrodes under various temperature conditions. The short response time, lifetime validity, recovery, and all the methods of validation such as limit of detection and limit of quantification were estimated. The potentiometric method turned out to be suitable for determining AV-MOXH in pharmacological formulations, and the findings obtained are comparable to the “HPLC official method” in terms of the agreement. As a result, the postulated potentiometric approach was verified in accordance with IUPAC guidelines.","PeriodicalId":20319,"journal":{"name":"Polimery","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2021-12-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors\",\"authors\":\"Sachin Kumar, Sushil K. Sindhu, Praveen Kumar, A. Sharma, S. Sagadevan\",\"doi\":\"10.14314/polimery.2021.11.4\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Three different carbon paste (CP), silk-screen (SP) and poly (vinyl chloride) (PVC) modified electrodes were obtained to verify the reliability of AVELOX, the generic name of which is Moxifloxacin HCl (AV-MOXH). The sensing membranes were containing AVELOX ion associated complexes with sodium tetraphenylborate (NaTPB), phosphomolybdic acid (PMA), phosphotungstic acid (PTA), and ammonium reineckate (RN) as electroactive materials. All three electrodes gave fast, viable, and near-Nernstian linear responses over a relative wide concentration range that ranged from 1.010-6 to 1.010-2 mol / L AV-MOXH at 25° C with a monovalent cationic decrease. The sensors demonstrated a good discernment of AV-MOXH from numerous inorganic and organic compounds such as glucose, sucrose, Na+, Ca+, etc. Additionally, the isothermal coefficients along with selectivity coefficients were calculated. The modified Screen Printed Electrode sensor appeared to be highly sensitive for the determination of AV-MOXH. The electrode response was observed in pH range 2--6 for ISPE electrodes and IPVC electrodes and 3--7 for ICPE electrodes under various temperature conditions. The short response time, lifetime validity, recovery, and all the methods of validation such as limit of detection and limit of quantification were estimated. The potentiometric method turned out to be suitable for determining AV-MOXH in pharmacological formulations, and the findings obtained are comparable to the “HPLC official method” in terms of the agreement. As a result, the postulated potentiometric approach was verified in accordance with IUPAC guidelines.\",\"PeriodicalId\":20319,\"journal\":{\"name\":\"Polimery\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2021-12-25\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Polimery\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.14314/polimery.2021.11.4\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"POLYMER SCIENCE\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Polimery","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.14314/polimery.2021.11.4","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"POLYMER SCIENCE","Score":null,"Total":0}
引用次数: 0

摘要

获得了三种不同的碳糊(CP)、丝网(SP)和聚氯乙烯(PVC)修饰电极,以验证AVELOX的可靠性。传感膜含有AVELOX离子缔合物与四苯基硼酸钠(NaTPB)、磷钼酸(PMA)、磷钨酸(PTA)和Reineck酸铵(RN)作为电活性材料。在相对较宽的浓度范围内,所有三个电极都给出了快速、可行且接近能斯特的线性响应,在25°C下,浓度范围为1.010-6至1.010-2 mol/L AV-MOXH,单价阳离子减少。传感器证明了AV-MOXH与许多无机和有机化合物(如葡萄糖、蔗糖、Na+、Ca+等)的良好区分。此外,还计算了等温系数和选择性系数。改进的丝网印刷电极传感器似乎对AV-MOXH的测定高度敏感。在不同的温度条件下,ISPE电极和IPVC电极的pH范围为2-6,ICPE电极的pH为3-7。估计了短响应时间、寿命有效性、回收率以及所有验证方法,如检测限和定量限。电位法被证明适用于测定药理学制剂中的AV-MOXH,所获得的结果在协议方面与“HPLC官方方法”相当。因此,根据IUPAC指南验证了假定的电位法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Determination of moxifloxacin hydrochloride in AVELOX pharmacological formulations using modified potentiometer sensors
Three different carbon paste (CP), silk-screen (SP) and poly (vinyl chloride) (PVC) modified electrodes were obtained to verify the reliability of AVELOX, the generic name of which is Moxifloxacin HCl (AV-MOXH). The sensing membranes were containing AVELOX ion associated complexes with sodium tetraphenylborate (NaTPB), phosphomolybdic acid (PMA), phosphotungstic acid (PTA), and ammonium reineckate (RN) as electroactive materials. All three electrodes gave fast, viable, and near-Nernstian linear responses over a relative wide concentration range that ranged from 1.010-6 to 1.010-2 mol / L AV-MOXH at 25° C with a monovalent cationic decrease. The sensors demonstrated a good discernment of AV-MOXH from numerous inorganic and organic compounds such as glucose, sucrose, Na+, Ca+, etc. Additionally, the isothermal coefficients along with selectivity coefficients were calculated. The modified Screen Printed Electrode sensor appeared to be highly sensitive for the determination of AV-MOXH. The electrode response was observed in pH range 2--6 for ISPE electrodes and IPVC electrodes and 3--7 for ICPE electrodes under various temperature conditions. The short response time, lifetime validity, recovery, and all the methods of validation such as limit of detection and limit of quantification were estimated. The potentiometric method turned out to be suitable for determining AV-MOXH in pharmacological formulations, and the findings obtained are comparable to the “HPLC official method” in terms of the agreement. As a result, the postulated potentiometric approach was verified in accordance with IUPAC guidelines.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Polimery
Polimery Materials Science-Polymers and Plastics
CiteScore
2.90
自引率
6.20%
发文量
35
审稿时长
1 months
期刊介绍: The "Polimery" journal, of international circulation, is publishing peerreviewed scientific and technical research papers covering polymer science and technology in the field of polymers, rubbers, chemical fibres and paints. The range of topics covered are raw materials, polymer synthesis, processing and applications of polymers. Apart from scientific and technical research papers the monthly includes technical and commercial information such as reports from fairs and exhibitions as well as home, world and technical news. “Polimery "- an international journal covering the following topics: polymers, rubber, chemical fibres and paints. The Journal is addressed to scientists, managers and engineering staff of universities, Polish Academy of Sciences, R&D institutions, industry, specializing in polymer chemistry, physical chemistry, technology and processing. “Polimery” publishes original, reviewed research, scientific and technology papers in the field of polymer synthesis, analysis, technology and modification, processing, properties, applications and recycling.
期刊最新文献
The effect of natural fillers on the mechanical properties and flammability of low-density polyethylene Rheological properties of polypropylene composites with calcium carbonate under high shear rates Zinc and graphene oxide composites as new protective coatings for oil and gas pipes New intumescent coatings for protection flammable materials interior and outside buildings Synthesis of molecularly printed methyl methacrylate-based polymers for the detection of di(2-ethylhexyl) phthalate and dibutyl phthalate
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1