James Halford, P. Foran
{"title":"了解鼓室测温在麻醉后监护室的应用:一篇讨论论文","authors":"James Halford, P. Foran","doi":"10.26550/2209-1092.1198","DOIUrl":null,"url":null,"abstract":"Inadvertent perioperative hypothermia (IPH) is an uncomfortable, dangerous and costly but preventable complication of surgery. For perioperative nurses to treat this condition, they must first have an accurate means of detecting it. In making clinical decisions based on patients’ temperature, an important vital sign, nurses must understand how different thermometers work and be competent in their use. It is vital that patients have accurate core body temperature recorded when admitted to the Post Anaesthesia Care Unit (PACU). Infrared tympanic thermometers are a non-invasive tool regularly used by PACU nurses and provide a quick and easily obtained measurement that is a reflection of core body temperature. Despite this, uncertainty remains about the accuracy of tympanic thermometer readings and their ability to accurately estimate core temperature, leading to questions being raised about their acceptability in clinical use. This discussion paper will evaluate the use of tympanic thermometers within the PACU and identify their benefits, limitations and alternatives, as well as the competency requirements of the nurse. Clinical trials give varying results and more research is needed into both the use of tympanic thermometers in the PACU and the competence of the user.","PeriodicalId":37332,"journal":{"name":"Journal of Perioperative Nursing","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-05-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Understanding the use of tympanic thermometry in the Post Anaesthesia Care Unit: A discussion paper\",\"authors\":\"James Halford, P. Foran\",\"doi\":\"10.26550/2209-1092.1198\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Inadvertent perioperative hypothermia (IPH) is an uncomfortable, dangerous and costly but preventable complication of surgery. For perioperative nurses to treat this condition, they must first have an accurate means of detecting it. In making clinical decisions based on patients’ temperature, an important vital sign, nurses must understand how different thermometers work and be competent in their use. It is vital that patients have accurate core body temperature recorded when admitted to the Post Anaesthesia Care Unit (PACU). Infrared tympanic thermometers are a non-invasive tool regularly used by PACU nurses and provide a quick and easily obtained measurement that is a reflection of core body temperature. Despite this, uncertainty remains about the accuracy of tympanic thermometer readings and their ability to accurately estimate core temperature, leading to questions being raised about their acceptability in clinical use. This discussion paper will evaluate the use of tympanic thermometers within the PACU and identify their benefits, limitations and alternatives, as well as the competency requirements of the nurse. Clinical trials give varying results and more research is needed into both the use of tympanic thermometers in the PACU and the competence of the user.\",\"PeriodicalId\":37332,\"journal\":{\"name\":\"Journal of Perioperative Nursing\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Perioperative Nursing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.26550/2209-1092.1198\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Nursing\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Perioperative Nursing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.26550/2209-1092.1198","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Nursing","Score":null,"Total":0}
引用次数: 0

摘要

围手术期意外低体温(IPH)是一种不舒服、危险、昂贵但可预防的手术并发症。对于围手术期护士来说,要治疗这种情况,他们必须首先有一个准确的检测手段。在根据病人的体温(一项重要的生命体征)做出临床决定时,护士必须了解不同的体温计是如何工作的,并能熟练使用。当患者进入麻醉后护理病房(PACU)时,准确记录核心体温是至关重要的。红外线鼓室体温计是PACU护士经常使用的一种非侵入性工具,它提供了一种快速、容易获得的测量结果,反映了核心体温。尽管如此,鼓室体温计读数的准确性及其准确估计核心温度的能力仍然存在不确定性,这导致人们对其在临床应用中的可接受性提出质疑。本文将评估鼓室温度计在PACU内的使用,并确定其优点、局限性和替代方案,以及护士的能力要求。临床试验给出了不同的结果,需要对PACU中鼓室温度计的使用和使用者的能力进行更多的研究。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Understanding the use of tympanic thermometry in the Post Anaesthesia Care Unit: A discussion paper
Inadvertent perioperative hypothermia (IPH) is an uncomfortable, dangerous and costly but preventable complication of surgery. For perioperative nurses to treat this condition, they must first have an accurate means of detecting it. In making clinical decisions based on patients’ temperature, an important vital sign, nurses must understand how different thermometers work and be competent in their use. It is vital that patients have accurate core body temperature recorded when admitted to the Post Anaesthesia Care Unit (PACU). Infrared tympanic thermometers are a non-invasive tool regularly used by PACU nurses and provide a quick and easily obtained measurement that is a reflection of core body temperature. Despite this, uncertainty remains about the accuracy of tympanic thermometer readings and their ability to accurately estimate core temperature, leading to questions being raised about their acceptability in clinical use. This discussion paper will evaluate the use of tympanic thermometers within the PACU and identify their benefits, limitations and alternatives, as well as the competency requirements of the nurse. Clinical trials give varying results and more research is needed into both the use of tympanic thermometers in the PACU and the competence of the user.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Perioperative Nursing
Journal of Perioperative Nursing Nursing-Medical and Surgical Nursing
CiteScore
0.70
自引率
0.00%
发文量
22
审稿时长
12 weeks
期刊最新文献
Effectiveness of fascia iliaca compartment block in adult fractured neck of femur patients: An integrative review Triggering change in perioperative pressure injury risk assessment: A project report Product stewardship in health care: The importance of minimising the environmental and health impacts of plastic products Advancing perioperative nursing education and surgical skills acquisition: A comprehensive approach Effectiveness of intra-operative gentamicin irrigation in reducing post-operative surgical site infections: A systematic review
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1