{"title":"压缩土块的抗压强度。不同测试方法的比较","authors":"Santiago Cabrera, Ariel Gonzalez, R. Rotondaro","doi":"10.3989/ic.70462","DOIUrl":null,"url":null,"abstract":"In this article, the effect that the geometry of test samples possesses on the average compressive strength determination on compressed earth blocks or CEBs is evaluated, as well as analyzing the effect of heading them with neoprene plates, with the purpose of obtaining references from the experimental process developed that allow to propose the redaction of a technical norm of the Argentinian Institute of Normalization and Certification (IRAM). To this end, specific technical standards for CEB written by Official Standards Organizations from different countries were compiled and analyzed, and the current regulatory framework of Argentina on concrete blocks, hollow and solid ceramic bricks was analyzed. Using CEBs produced by different establishments around the country, tests samples with different geometries were made, and their compressive strength with and without neoprene plates heading was determined. The obtained results indicate that the most adequate test samples for non-confined compressive strength determination on CEBs are an entire block or halve CEB, both in horizontal position and without heading.","PeriodicalId":54981,"journal":{"name":"Informes De La Construccion","volume":null,"pages":null},"PeriodicalIF":0.4000,"publicationDate":"2020-10-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Resistencia a compresión en Bloques de Tierra Comprimida. Comparación entre diferentes métodos de ensayo\",\"authors\":\"Santiago Cabrera, Ariel Gonzalez, R. Rotondaro\",\"doi\":\"10.3989/ic.70462\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In this article, the effect that the geometry of test samples possesses on the average compressive strength determination on compressed earth blocks or CEBs is evaluated, as well as analyzing the effect of heading them with neoprene plates, with the purpose of obtaining references from the experimental process developed that allow to propose the redaction of a technical norm of the Argentinian Institute of Normalization and Certification (IRAM). To this end, specific technical standards for CEB written by Official Standards Organizations from different countries were compiled and analyzed, and the current regulatory framework of Argentina on concrete blocks, hollow and solid ceramic bricks was analyzed. Using CEBs produced by different establishments around the country, tests samples with different geometries were made, and their compressive strength with and without neoprene plates heading was determined. The obtained results indicate that the most adequate test samples for non-confined compressive strength determination on CEBs are an entire block or halve CEB, both in horizontal position and without heading.\",\"PeriodicalId\":54981,\"journal\":{\"name\":\"Informes De La Construccion\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.4000,\"publicationDate\":\"2020-10-27\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Informes De La Construccion\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.3989/ic.70462\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"CONSTRUCTION & BUILDING TECHNOLOGY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Informes De La Construccion","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3989/ic.70462","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CONSTRUCTION & BUILDING TECHNOLOGY","Score":null,"Total":0}
Resistencia a compresión en Bloques de Tierra Comprimida. Comparación entre diferentes métodos de ensayo
In this article, the effect that the geometry of test samples possesses on the average compressive strength determination on compressed earth blocks or CEBs is evaluated, as well as analyzing the effect of heading them with neoprene plates, with the purpose of obtaining references from the experimental process developed that allow to propose the redaction of a technical norm of the Argentinian Institute of Normalization and Certification (IRAM). To this end, specific technical standards for CEB written by Official Standards Organizations from different countries were compiled and analyzed, and the current regulatory framework of Argentina on concrete blocks, hollow and solid ceramic bricks was analyzed. Using CEBs produced by different establishments around the country, tests samples with different geometries were made, and their compressive strength with and without neoprene plates heading was determined. The obtained results indicate that the most adequate test samples for non-confined compressive strength determination on CEBs are an entire block or halve CEB, both in horizontal position and without heading.
期刊介绍:
Founded in 1948 by the Instituto Técnico de la Construcción y del Cemento, Informes de la Construcción is a scientific journal issued quarterly. Its articles cover fields such as architecture, engineering, public works, environment, building services, rehabilitation, construction systems, testing techniques, results of research on building components and systems and so forth. Journal"s readership includes architects, engineers and construction companies, as well as researchers and professionals engaging in building construction and public works.