Shakar Jamal Aweez, Z. Salih, Lubna ahmad abdulkarim, A. M. Asaad
{"title":"发电机品牌对土壤和植物中重金属浓度的影响","authors":"Shakar Jamal Aweez, Z. Salih, Lubna ahmad abdulkarim, A. M. Asaad","doi":"10.21271/zjpas.35.3.17","DOIUrl":null,"url":null,"abstract":"of contamination was (249.199) were recorded in (B3S5). According to contamination factor their indications of low contamination (B2S9) moderate contamination factor for (B2S9) considerable contamination factor for (B2S2, B2S9, B3S5, B3S1), with high degree of contamination in (B3S5). The ecological risk factor and RI with the highest values were (53.682, 6986.193, 6.046, 21.027, 1.697, 20.507,13.936) and RI was (7081.261), which were recorded in (B1S2, B3S5, B2S9, B3S5, B3S1, B2S7) and (B3S5), respectively. The ecological risk factor and potential ecological risk indices showed that (B2S9, B3S5, B3S1, B2S7) low potential ecological risk, (B1S2) moderate potential ecological risk, (B3S5) very high ecological risk. The biological accumulation coefficient factor of two different plants ( Eucalyptus amygdalina Labill, (Plant1), and Dodonaea viscosa Jacq (Plant2 ) are (8.433, 15.358, 23.311, 42.236, 52.626, 48.094, 0.190) which were recorded in (B3S8P1, B2S7P1,S3S5P2, B2S9P2, B2S7P2, B3S8P1,B3S4P1.The aim of this study is to assess the effect of the brand electrical generator on concentration heavy metal in soil and dust soil and plant heavy metal levels in Erbil city","PeriodicalId":23933,"journal":{"name":"ZANCO Journal of Pure and Applied Sciences","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-06-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effects of the Brand of Electrical Generator on the Concentration of Heavy Metals in Soil and Plants\",\"authors\":\"Shakar Jamal Aweez, Z. Salih, Lubna ahmad abdulkarim, A. M. Asaad\",\"doi\":\"10.21271/zjpas.35.3.17\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"of contamination was (249.199) were recorded in (B3S5). According to contamination factor their indications of low contamination (B2S9) moderate contamination factor for (B2S9) considerable contamination factor for (B2S2, B2S9, B3S5, B3S1), with high degree of contamination in (B3S5). The ecological risk factor and RI with the highest values were (53.682, 6986.193, 6.046, 21.027, 1.697, 20.507,13.936) and RI was (7081.261), which were recorded in (B1S2, B3S5, B2S9, B3S5, B3S1, B2S7) and (B3S5), respectively. The ecological risk factor and potential ecological risk indices showed that (B2S9, B3S5, B3S1, B2S7) low potential ecological risk, (B1S2) moderate potential ecological risk, (B3S5) very high ecological risk. The biological accumulation coefficient factor of two different plants ( Eucalyptus amygdalina Labill, (Plant1), and Dodonaea viscosa Jacq (Plant2 ) are (8.433, 15.358, 23.311, 42.236, 52.626, 48.094, 0.190) which were recorded in (B3S8P1, B2S7P1,S3S5P2, B2S9P2, B2S7P2, B3S8P1,B3S4P1.The aim of this study is to assess the effect of the brand electrical generator on concentration heavy metal in soil and dust soil and plant heavy metal levels in Erbil city\",\"PeriodicalId\":23933,\"journal\":{\"name\":\"ZANCO Journal of Pure and Applied Sciences\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-06-14\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ZANCO Journal of Pure and Applied Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.21271/zjpas.35.3.17\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ZANCO Journal of Pure and Applied Sciences","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.21271/zjpas.35.3.17","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Effects of the Brand of Electrical Generator on the Concentration of Heavy Metals in Soil and Plants
of contamination was (249.199) were recorded in (B3S5). According to contamination factor their indications of low contamination (B2S9) moderate contamination factor for (B2S9) considerable contamination factor for (B2S2, B2S9, B3S5, B3S1), with high degree of contamination in (B3S5). The ecological risk factor and RI with the highest values were (53.682, 6986.193, 6.046, 21.027, 1.697, 20.507,13.936) and RI was (7081.261), which were recorded in (B1S2, B3S5, B2S9, B3S5, B3S1, B2S7) and (B3S5), respectively. The ecological risk factor and potential ecological risk indices showed that (B2S9, B3S5, B3S1, B2S7) low potential ecological risk, (B1S2) moderate potential ecological risk, (B3S5) very high ecological risk. The biological accumulation coefficient factor of two different plants ( Eucalyptus amygdalina Labill, (Plant1), and Dodonaea viscosa Jacq (Plant2 ) are (8.433, 15.358, 23.311, 42.236, 52.626, 48.094, 0.190) which were recorded in (B3S8P1, B2S7P1,S3S5P2, B2S9P2, B2S7P2, B3S8P1,B3S4P1.The aim of this study is to assess the effect of the brand electrical generator on concentration heavy metal in soil and dust soil and plant heavy metal levels in Erbil city