综合臭氧和UVC-LED技术对雾滴中鼠伤寒沙门菌减少效果的研究

IF 1.1 Q4 METEOROLOGY & ATMOSPHERIC SCIENCES Asian Journal of Atmospheric Environment Pub Date : 2021-09-17 DOI:10.5572/ajae.2021.100
Jee-Hyun Lee, Trieu-Vuong Dinh, Chang-Seon Song, Kee-Jong Hong, Jo-Chun Kim
{"title":"综合臭氧和UVC-LED技术对雾滴中鼠伤寒沙门菌减少效果的研究","authors":"Jee-Hyun Lee,&nbsp;Trieu-Vuong Dinh,&nbsp;Chang-Seon Song,&nbsp;Kee-Jong Hong,&nbsp;Jo-Chun Kim","doi":"10.5572/ajae.2021.100","DOIUrl":null,"url":null,"abstract":"<div><p>In the wake of the SARS-CoV-2 pandemic, inactivating bioaerosols became a pivotal issue which helps to prevent the transmittance of SARS-CoV-2. Thus, the current study was conducted to investigate a potential inactivating method using both ozone (O<sub>3</sub>) and ultraviolet C (UVC). Individual and integrated effects of O<sub>3</sub> and UVC were compared. A solution containing approximately 4~7.3×10<sup>6</sup> CFU/mL of <i>Salmonella typhimurium</i> bacteria was used to produce bacteria droplets. These droplets were exposed to O<sub>3</sub> and UVC to determine the reduction rate of bacteria. The exposure times were set as 1 and 30 minutes. Ozone concentrations were 100 and 200 ppmv. UVC-LEDs were used as a UVC source. Peak wavelength of the UVC-LED was 275 nm and the irradiation dose was 0.77 mW/cm<sup>2</sup>. In terms of O<sub>3</sub> and UVC-LED interaction, 194 ppmv styrene was used as a target compound to be removed. Considering the O<sub>3</sub> and UVC-LED interaction, the presence of O<sub>3</sub> could reduce the performance of the UVC-LED, and UVC-LED could also reduce significant amount of O<sub>3</sub>. The sequence of O<sub>3</sub> and UVC-LED treatment was as follows: O<sub>3</sub> was exposed at first, then UVC-LED, and this order showed the best reduction ratio (&gt;99.9%). Therefore, if O<sub>3</sub> and UVC-LED is used to disinfect <i>Salmonella typhimurium</i> bacteria contained in droplets, bacteria should be separately exposed to O<sub>3</sub> and UVC-LED in order to improve the inactivation efficiency.</p></div>","PeriodicalId":45358,"journal":{"name":"Asian Journal of Atmospheric Environment","volume":null,"pages":null},"PeriodicalIF":1.1000,"publicationDate":"2021-09-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://link.springer.com/content/pdf/10.5572/ajae.2021.100.pdf","citationCount":"0","resultStr":"{\"title\":\"A Study on the Effect of Integrated Ozone and UVC-LED Approaches on the Reduction of Salmonella typhimurium Bacteria in Droplets\",\"authors\":\"Jee-Hyun Lee,&nbsp;Trieu-Vuong Dinh,&nbsp;Chang-Seon Song,&nbsp;Kee-Jong Hong,&nbsp;Jo-Chun Kim\",\"doi\":\"10.5572/ajae.2021.100\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>In the wake of the SARS-CoV-2 pandemic, inactivating bioaerosols became a pivotal issue which helps to prevent the transmittance of SARS-CoV-2. Thus, the current study was conducted to investigate a potential inactivating method using both ozone (O<sub>3</sub>) and ultraviolet C (UVC). Individual and integrated effects of O<sub>3</sub> and UVC were compared. A solution containing approximately 4~7.3×10<sup>6</sup> CFU/mL of <i>Salmonella typhimurium</i> bacteria was used to produce bacteria droplets. These droplets were exposed to O<sub>3</sub> and UVC to determine the reduction rate of bacteria. The exposure times were set as 1 and 30 minutes. Ozone concentrations were 100 and 200 ppmv. UVC-LEDs were used as a UVC source. Peak wavelength of the UVC-LED was 275 nm and the irradiation dose was 0.77 mW/cm<sup>2</sup>. In terms of O<sub>3</sub> and UVC-LED interaction, 194 ppmv styrene was used as a target compound to be removed. Considering the O<sub>3</sub> and UVC-LED interaction, the presence of O<sub>3</sub> could reduce the performance of the UVC-LED, and UVC-LED could also reduce significant amount of O<sub>3</sub>. The sequence of O<sub>3</sub> and UVC-LED treatment was as follows: O<sub>3</sub> was exposed at first, then UVC-LED, and this order showed the best reduction ratio (&gt;99.9%). Therefore, if O<sub>3</sub> and UVC-LED is used to disinfect <i>Salmonella typhimurium</i> bacteria contained in droplets, bacteria should be separately exposed to O<sub>3</sub> and UVC-LED in order to improve the inactivation efficiency.</p></div>\",\"PeriodicalId\":45358,\"journal\":{\"name\":\"Asian Journal of Atmospheric Environment\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":1.1000,\"publicationDate\":\"2021-09-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://link.springer.com/content/pdf/10.5572/ajae.2021.100.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Asian Journal of Atmospheric Environment\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://link.springer.com/article/10.5572/ajae.2021.100\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"METEOROLOGY & ATMOSPHERIC SCIENCES\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Asian Journal of Atmospheric Environment","FirstCategoryId":"1085","ListUrlMain":"https://link.springer.com/article/10.5572/ajae.2021.100","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"METEOROLOGY & ATMOSPHERIC SCIENCES","Score":null,"Total":0}
引用次数: 0

摘要

在严重急性呼吸系统综合征冠状病毒2型大流行之后,灭活生物气溶胶成为一个关键问题,有助于防止严重急性呼吸系冠状病毒2型的传播。因此,本研究旨在研究一种使用臭氧(O3)和紫外线C(UVC)的潜在灭活方法。比较了O3和UVC的单独作用和综合作用。使用含有约4⁓7.3×106CFU/mL鼠伤寒沙门氏菌的溶液来产生菌滴。将这些液滴暴露于O3和UVC以确定细菌的还原率。曝光时间设定为1分钟和30分钟。臭氧浓度分别为100和200 ppmv。UVC LED被用作UVC源。UVC-LED的峰值波长为275nm,照射剂量为0.77mW/cm2。就O3和UVC-LED的相互作用而言,使用194ppmv苯乙烯作为要去除的目标化合物。考虑到O3和UVC-LED的相互作用,O3的存在会降低UVC-LED性能,UVC-LED也会显著降低O3的含量。O3和UVC-LED处理的顺序如下:首先暴露O3,然后暴露UVC-LED,并且这个顺序显示出最佳的还原率(≻99.9%)。因此,如果使用O3和UVC-LED对液滴中含有的鼠伤寒沙门氏菌进行消毒,则细菌应分别暴露于O3和UVC-LED,以提高灭活效率。©2021。这是一篇根据知识共享署名非商业许可条款发布的开放获取文章(http://creativecommons.org/licenses/by-nc/4.0/),允许在任何媒体上不受限制地进行非商业性使用、分发和复制,前提是正确引用了原作。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
A Study on the Effect of Integrated Ozone and UVC-LED Approaches on the Reduction of Salmonella typhimurium Bacteria in Droplets

In the wake of the SARS-CoV-2 pandemic, inactivating bioaerosols became a pivotal issue which helps to prevent the transmittance of SARS-CoV-2. Thus, the current study was conducted to investigate a potential inactivating method using both ozone (O3) and ultraviolet C (UVC). Individual and integrated effects of O3 and UVC were compared. A solution containing approximately 4~7.3×106 CFU/mL of Salmonella typhimurium bacteria was used to produce bacteria droplets. These droplets were exposed to O3 and UVC to determine the reduction rate of bacteria. The exposure times were set as 1 and 30 minutes. Ozone concentrations were 100 and 200 ppmv. UVC-LEDs were used as a UVC source. Peak wavelength of the UVC-LED was 275 nm and the irradiation dose was 0.77 mW/cm2. In terms of O3 and UVC-LED interaction, 194 ppmv styrene was used as a target compound to be removed. Considering the O3 and UVC-LED interaction, the presence of O3 could reduce the performance of the UVC-LED, and UVC-LED could also reduce significant amount of O3. The sequence of O3 and UVC-LED treatment was as follows: O3 was exposed at first, then UVC-LED, and this order showed the best reduction ratio (>99.9%). Therefore, if O3 and UVC-LED is used to disinfect Salmonella typhimurium bacteria contained in droplets, bacteria should be separately exposed to O3 and UVC-LED in order to improve the inactivation efficiency.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Asian Journal of Atmospheric Environment
Asian Journal of Atmospheric Environment METEOROLOGY & ATMOSPHERIC SCIENCES-
CiteScore
2.80
自引率
6.70%
发文量
22
审稿时长
21 weeks
期刊最新文献
Characteristic of PM2.5 concentration and source apportionment during winter in Seosan, Korea A case study on the effect of contaminated inlet tubes on the accuracy of mid-cost optical particle counters for the ambient air monitoring of fine particles Vertical profile measurements for ammonia in a Japanese deciduous forest using denuder sampling technique: ammonia emissions near the forest floor Assessment of vehicle exhaust PM emissions using high-resolution on-road measurements in Seoul, Korea Satellite measurement data-based assessment of spatiotemporal characteristics of ultraviolet index (UVI) over the state of Johor, Malaysia
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1