D. Varela-Olalla, Darío Álvarez-Salvador, Alejandro Arias-Tomé, Ignacio Collado-Lázaro, Aitor Gamarra-Calavia, C. Balsalobre-Fernández
{"title":"一种新型惯性测量单元跟踪杠铃速度的有效性","authors":"D. Varela-Olalla, Darío Álvarez-Salvador, Alejandro Arias-Tomé, Ignacio Collado-Lázaro, Aitor Gamarra-Calavia, C. Balsalobre-Fernández","doi":"10.18176/archmeddeporte.00051","DOIUrl":null,"url":null,"abstract":"The objective of this work is to analyze the reliability and validity of the new inertial measurement unit (IMU) PUSHTM Band 2.0 to measure barbell velocity. Six healthy males (24.83±3.71years; 69.88±8.36kg; 175.92±4.5cm) participated in this study and performed several sets on the bench press. Barbell concentric mean (MV) and peak (PV) velocity were recorded with a LT and the IMU. Pearson correlation coefficient shows a very high relationship for MV (r = 0.97; SEE: 0.08 m/s; 95%CI: 0.95-0.98; p< 0.001) and PV (r = 0.97; SEE: 0.13 m/s; 95%CI: 0.96-0.98; p< 0.001). There was a very high agreement for the values of MV and PV (MV: ICC = 0.945, CI = 0.834–0.974, α = 0.981; PV: ICC = 0.926, CI = 0.708–0.969, α = 0.977). Paired sample t-test revealed systematic bias for MV (p< 0.001; mean difference between instruments = 0.06 ± 0.09 m/s) and PV (p< 0.001; mean difference between instruments = 0.15 ± 0.18 m/s). Bland-Altman plots showed almost trivial and moderate relationships for MV (r2 = 0.1) and PV (r2 = 0.37). In conclusion, the PUSHTM Band 2.0 was proven to be a valid alternative for measuring barbell velocity in the bench press.","PeriodicalId":38936,"journal":{"name":"Archivos de Medicina del Deporte","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2021-08-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Validity of a novel inertial measurement unit to track barbell velocity\",\"authors\":\"D. Varela-Olalla, Darío Álvarez-Salvador, Alejandro Arias-Tomé, Ignacio Collado-Lázaro, Aitor Gamarra-Calavia, C. Balsalobre-Fernández\",\"doi\":\"10.18176/archmeddeporte.00051\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The objective of this work is to analyze the reliability and validity of the new inertial measurement unit (IMU) PUSHTM Band 2.0 to measure barbell velocity. Six healthy males (24.83±3.71years; 69.88±8.36kg; 175.92±4.5cm) participated in this study and performed several sets on the bench press. Barbell concentric mean (MV) and peak (PV) velocity were recorded with a LT and the IMU. Pearson correlation coefficient shows a very high relationship for MV (r = 0.97; SEE: 0.08 m/s; 95%CI: 0.95-0.98; p< 0.001) and PV (r = 0.97; SEE: 0.13 m/s; 95%CI: 0.96-0.98; p< 0.001). There was a very high agreement for the values of MV and PV (MV: ICC = 0.945, CI = 0.834–0.974, α = 0.981; PV: ICC = 0.926, CI = 0.708–0.969, α = 0.977). Paired sample t-test revealed systematic bias for MV (p< 0.001; mean difference between instruments = 0.06 ± 0.09 m/s) and PV (p< 0.001; mean difference between instruments = 0.15 ± 0.18 m/s). Bland-Altman plots showed almost trivial and moderate relationships for MV (r2 = 0.1) and PV (r2 = 0.37). In conclusion, the PUSHTM Band 2.0 was proven to be a valid alternative for measuring barbell velocity in the bench press.\",\"PeriodicalId\":38936,\"journal\":{\"name\":\"Archivos de Medicina del Deporte\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-08-23\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archivos de Medicina del Deporte\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.18176/archmeddeporte.00051\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archivos de Medicina del Deporte","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18176/archmeddeporte.00051","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0
摘要
本工作的目的是分析新型惯性测量单元PUSHTM Band 2.0测量杠铃速度的可靠性和有效性。6名健康男性(24.83±3.71岁;69.88±8.36kg;175.92±4.5cm)参加了这项研究,并在卧推上进行了几组。用LT和IMU记录Barbell同心平均值(MV)和峰值(PV)速度。Pearson相关系数显示MV(r=0.97;SEE:0.08 m/s;95%CI:0.95-0.98;p<0.001)和PV(r=0.95;SEE:0.13 m/s;95%CI:0.96-0.98;p<0.001)的相关性非常高。MV和PV的值非常一致(MV:ICC=0.945,CI=0.834–0.974,α=0.981;PV:ICC=0.9 26,CI=0.708–0.969,α=0.9 77)。配对样本t检验显示MV的系统偏差(p<0.001;仪器之间的平均差=0.06±0.09 m/s)和PV(p<001;仪器之间平均差=0.15±0.18 m/s)。Bland-Altman图显示MV(r2=0.1)和PV(r2=0.37)之间几乎是琐碎和适度的关系。总之,PUSHTM Band 2.0被证明是测量台式压力机杠铃速度的有效替代方案。
Validity of a novel inertial measurement unit to track barbell velocity
The objective of this work is to analyze the reliability and validity of the new inertial measurement unit (IMU) PUSHTM Band 2.0 to measure barbell velocity. Six healthy males (24.83±3.71years; 69.88±8.36kg; 175.92±4.5cm) participated in this study and performed several sets on the bench press. Barbell concentric mean (MV) and peak (PV) velocity were recorded with a LT and the IMU. Pearson correlation coefficient shows a very high relationship for MV (r = 0.97; SEE: 0.08 m/s; 95%CI: 0.95-0.98; p< 0.001) and PV (r = 0.97; SEE: 0.13 m/s; 95%CI: 0.96-0.98; p< 0.001). There was a very high agreement for the values of MV and PV (MV: ICC = 0.945, CI = 0.834–0.974, α = 0.981; PV: ICC = 0.926, CI = 0.708–0.969, α = 0.977). Paired sample t-test revealed systematic bias for MV (p< 0.001; mean difference between instruments = 0.06 ± 0.09 m/s) and PV (p< 0.001; mean difference between instruments = 0.15 ± 0.18 m/s). Bland-Altman plots showed almost trivial and moderate relationships for MV (r2 = 0.1) and PV (r2 = 0.37). In conclusion, the PUSHTM Band 2.0 was proven to be a valid alternative for measuring barbell velocity in the bench press.