基于数据挖掘技术的对称-单极-多端VSC-HVDC继电支持

IF 3.8 Q2 COMPUTER SCIENCE, INFORMATION SYSTEMS Applied System Innovation Pub Date : 2023-02-05 DOI:10.3390/asi6010024
Abha Pragati, D. A. Gadanayak, Tanmoy Parida, Manohar Mishra
{"title":"基于数据挖掘技术的对称-单极-多端VSC-HVDC继电支持","authors":"Abha Pragati, D. A. Gadanayak, Tanmoy Parida, Manohar Mishra","doi":"10.3390/asi6010024","DOIUrl":null,"url":null,"abstract":"Considering the advantage of the ability of data-mining techniques (DMTs) to detect and classify patterns, this paper explores their applicability for the protection of voltage source converter-based high voltage direct current (VSC-HVDC) transmission systems. In spite of the location of fault occurring points such as external/internal, rectifier-substation/inverter-substation, and positive/negative pole of the DC line, the stated approach is capable of accurate fault detection, classification, and location. Initially, the local voltage and current measurements at one end of the HVDC system are used in this work to extract the feature vector. Once the feature vector is retrieved, the DMTs are trained and tested to identify the fault types (internal DC faults, external AC faults, and external DC faults) and fault location in the particular feeder. In the data-mining framework, several state-of-the-art machine learning (ML) models along with one advanced deep learning (DL) model are used for training and testing. The proposed VSC-HVDC relaying system is comprehensively tested on a symmetric-monopolar-multi-terminal VSC-HVDC system and presents heartening results in diverse operating conditions. The results show that the studied deep belief network (DBN) based DL model performs better compared with other ML models in both fault classification and location. The accuracy of fault classification of the DBN is found to be 98.9% in the noiseless condition and 91.8% in the 20 dB noisy condition. Similarly, the DBN-based DMT is found to be effective in fault locations in the HVDC system with a smaller percentage of errors as MSE: 2.116, RMSE: 1.4531, and MAPE: 2.7047. This approach can be used as an effective low-cost relaying support tool for the VSC-HVDC system, as it does not necessitate a communication channel.","PeriodicalId":36273,"journal":{"name":"Applied System Innovation","volume":" ","pages":""},"PeriodicalIF":3.8000,"publicationDate":"2023-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"3","resultStr":"{\"title\":\"Data-Mining Techniques Based Relaying Support for Symmetric-Monopolar-Multi-Terminal VSC-HVDC System\",\"authors\":\"Abha Pragati, D. A. Gadanayak, Tanmoy Parida, Manohar Mishra\",\"doi\":\"10.3390/asi6010024\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Considering the advantage of the ability of data-mining techniques (DMTs) to detect and classify patterns, this paper explores their applicability for the protection of voltage source converter-based high voltage direct current (VSC-HVDC) transmission systems. In spite of the location of fault occurring points such as external/internal, rectifier-substation/inverter-substation, and positive/negative pole of the DC line, the stated approach is capable of accurate fault detection, classification, and location. Initially, the local voltage and current measurements at one end of the HVDC system are used in this work to extract the feature vector. Once the feature vector is retrieved, the DMTs are trained and tested to identify the fault types (internal DC faults, external AC faults, and external DC faults) and fault location in the particular feeder. In the data-mining framework, several state-of-the-art machine learning (ML) models along with one advanced deep learning (DL) model are used for training and testing. The proposed VSC-HVDC relaying system is comprehensively tested on a symmetric-monopolar-multi-terminal VSC-HVDC system and presents heartening results in diverse operating conditions. The results show that the studied deep belief network (DBN) based DL model performs better compared with other ML models in both fault classification and location. The accuracy of fault classification of the DBN is found to be 98.9% in the noiseless condition and 91.8% in the 20 dB noisy condition. Similarly, the DBN-based DMT is found to be effective in fault locations in the HVDC system with a smaller percentage of errors as MSE: 2.116, RMSE: 1.4531, and MAPE: 2.7047. This approach can be used as an effective low-cost relaying support tool for the VSC-HVDC system, as it does not necessitate a communication channel.\",\"PeriodicalId\":36273,\"journal\":{\"name\":\"Applied System Innovation\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":3.8000,\"publicationDate\":\"2023-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"3\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Applied System Innovation\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3390/asi6010024\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"COMPUTER SCIENCE, INFORMATION SYSTEMS\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied System Innovation","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/asi6010024","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"COMPUTER SCIENCE, INFORMATION SYSTEMS","Score":null,"Total":0}
引用次数: 3

摘要

考虑到数据挖掘技术(dmt)在模式检测和分类方面的优势,本文探讨了数据挖掘技术在基于电压源变流器的高压直流输电系统保护中的适用性。不管故障发生点的位置是外部/内部、整流-变电/逆变-变电、直流线路的正/负极,所述方法都能够准确地检测、分类和定位故障。首先,本文使用高压直流系统一端的局部电压和电流测量来提取特征向量。一旦特征向量被检索,dmt被训练和测试以识别故障类型(内部直流故障、外部交流故障和外部直流故障)和特定馈线中的故障位置。在数据挖掘框架中,几个最先进的机器学习(ML)模型以及一个先进的深度学习(DL)模型用于训练和测试。在对称-单极-多端vdc - hvdc系统上对所提出的vdc - hvdc继电保护系统进行了全面测试,并在多种工况下取得了令人振奋的结果。结果表明,所研究的基于深度信念网络(DBN)的深度学习模型在故障分类和定位方面都优于其他深度学习模型。在无噪声条件下,DBN的故障分类准确率为98.9%,在20 dB噪声条件下,准确率为91.8%。同样,基于dbn的DMT在高压直流系统的故障定位中有效,误差百分比较小,MSE: 2.116, RMSE: 1.4531, MAPE: 2.7047。这种方法可以作为一种有效的低成本的VSC-HVDC系统中继支持工具,因为它不需要通信通道。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Data-Mining Techniques Based Relaying Support for Symmetric-Monopolar-Multi-Terminal VSC-HVDC System
Considering the advantage of the ability of data-mining techniques (DMTs) to detect and classify patterns, this paper explores their applicability for the protection of voltage source converter-based high voltage direct current (VSC-HVDC) transmission systems. In spite of the location of fault occurring points such as external/internal, rectifier-substation/inverter-substation, and positive/negative pole of the DC line, the stated approach is capable of accurate fault detection, classification, and location. Initially, the local voltage and current measurements at one end of the HVDC system are used in this work to extract the feature vector. Once the feature vector is retrieved, the DMTs are trained and tested to identify the fault types (internal DC faults, external AC faults, and external DC faults) and fault location in the particular feeder. In the data-mining framework, several state-of-the-art machine learning (ML) models along with one advanced deep learning (DL) model are used for training and testing. The proposed VSC-HVDC relaying system is comprehensively tested on a symmetric-monopolar-multi-terminal VSC-HVDC system and presents heartening results in diverse operating conditions. The results show that the studied deep belief network (DBN) based DL model performs better compared with other ML models in both fault classification and location. The accuracy of fault classification of the DBN is found to be 98.9% in the noiseless condition and 91.8% in the 20 dB noisy condition. Similarly, the DBN-based DMT is found to be effective in fault locations in the HVDC system with a smaller percentage of errors as MSE: 2.116, RMSE: 1.4531, and MAPE: 2.7047. This approach can be used as an effective low-cost relaying support tool for the VSC-HVDC system, as it does not necessitate a communication channel.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Applied System Innovation
Applied System Innovation Mathematics-Applied Mathematics
CiteScore
7.90
自引率
5.30%
发文量
102
审稿时长
11 weeks
期刊最新文献
Research on Chinese Nested Entity Recognition Based on IDCNNLR and GlobalPointer AI-Powered Academic Guidance and Counseling System Based on Student Profile and Interests Using Smart Traffic Lights to Reduce CO2 Emissions and Improve Traffic Flow at Intersections: Simulation of an Intersection in a Small Portuguese City Predictive Modeling of Light–Matter Interaction in One Dimension: A Dynamic Deep Learning Approach Project Management Efficiency Measurement with Data Envelopment Analysis: A Case in a Petrochemical Company
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1