{"title":"UFP分解单元在故障恢复模式和退化条件下可靠性指标的过程建模","authors":"Amit Kumar, M. Ram","doi":"10.1108/jqme-01-2022-0008","DOIUrl":null,"url":null,"abstract":"PurposeEnsuring safe operation of a urea fertilizer plant (UFP) is a vital aspect for its functioning and production. Clearly the safe operation of such systems can only be archived with proper and effective maintenance scheduling and through controlling its failures as well as repairs of the components. Also for this, the concern plant management must have the information regarding the failures that affects the system's performance most/least. The objective of this study is to analyze mathematically the factors that are responsible for the failure/degradation of the decomposition unit of UFP.Design/methodology/approachThe considered system has been modeled by the aid of Markov's birth–death process with two types of failures for its components: variable (which are very similar in practical situations) and constant. The mathematical model is solved by the help of Laplace transform and supplementary variable technique.FindingsIn the present paper, the availability, reliability and mean time to failure (MTTF) are computed for the decomposition unit of the UFP. The critical components that affect the reliability and MTTF of the decomposition unit are identified through sensitivity analysis.Originality/valueIn this paper, a mathematical model based on the working of the decomposition unit of a UFP has been developed by considering two types of failure, namely, variable failures rates and constant failure rates (which has not been done in the literature for the decomposition unit). Conclusions in this paper are good references for the improvement of the same.","PeriodicalId":16938,"journal":{"name":"Journal of Quality in Maintenance Engineering","volume":" ","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2023-01-31","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Process modeling for decomposition unit of a UFP for reliability indices subject to fail-back mode and degradation\",\"authors\":\"Amit Kumar, M. Ram\",\"doi\":\"10.1108/jqme-01-2022-0008\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"PurposeEnsuring safe operation of a urea fertilizer plant (UFP) is a vital aspect for its functioning and production. Clearly the safe operation of such systems can only be archived with proper and effective maintenance scheduling and through controlling its failures as well as repairs of the components. Also for this, the concern plant management must have the information regarding the failures that affects the system's performance most/least. The objective of this study is to analyze mathematically the factors that are responsible for the failure/degradation of the decomposition unit of UFP.Design/methodology/approachThe considered system has been modeled by the aid of Markov's birth–death process with two types of failures for its components: variable (which are very similar in practical situations) and constant. The mathematical model is solved by the help of Laplace transform and supplementary variable technique.FindingsIn the present paper, the availability, reliability and mean time to failure (MTTF) are computed for the decomposition unit of the UFP. The critical components that affect the reliability and MTTF of the decomposition unit are identified through sensitivity analysis.Originality/valueIn this paper, a mathematical model based on the working of the decomposition unit of a UFP has been developed by considering two types of failure, namely, variable failures rates and constant failure rates (which has not been done in the literature for the decomposition unit). Conclusions in this paper are good references for the improvement of the same.\",\"PeriodicalId\":16938,\"journal\":{\"name\":\"Journal of Quality in Maintenance Engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.8000,\"publicationDate\":\"2023-01-31\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Quality in Maintenance Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1108/jqme-01-2022-0008\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, INDUSTRIAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Quality in Maintenance Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1108/jqme-01-2022-0008","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, INDUSTRIAL","Score":null,"Total":0}
Process modeling for decomposition unit of a UFP for reliability indices subject to fail-back mode and degradation
PurposeEnsuring safe operation of a urea fertilizer plant (UFP) is a vital aspect for its functioning and production. Clearly the safe operation of such systems can only be archived with proper and effective maintenance scheduling and through controlling its failures as well as repairs of the components. Also for this, the concern plant management must have the information regarding the failures that affects the system's performance most/least. The objective of this study is to analyze mathematically the factors that are responsible for the failure/degradation of the decomposition unit of UFP.Design/methodology/approachThe considered system has been modeled by the aid of Markov's birth–death process with two types of failures for its components: variable (which are very similar in practical situations) and constant. The mathematical model is solved by the help of Laplace transform and supplementary variable technique.FindingsIn the present paper, the availability, reliability and mean time to failure (MTTF) are computed for the decomposition unit of the UFP. The critical components that affect the reliability and MTTF of the decomposition unit are identified through sensitivity analysis.Originality/valueIn this paper, a mathematical model based on the working of the decomposition unit of a UFP has been developed by considering two types of failure, namely, variable failures rates and constant failure rates (which has not been done in the literature for the decomposition unit). Conclusions in this paper are good references for the improvement of the same.
期刊介绍:
This exciting journal looks at maintenance engineering from a positive standpoint, and clarifies its recently elevatedstatus as a highly technical, scientific, and complex field. Typical areas examined include: ■Budget and control ■Equipment management ■Maintenance information systems ■Process capability and maintenance ■Process monitoring techniques ■Reliability-based maintenance ■Replacement and life cycle costs ■TQM and maintenance