使用体积调制弧线治疗的全身照射,巴基斯坦一家癌症医院的经验

IF 0.3 Q4 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING Journal of Radiotherapy in Practice Pub Date : 2022-08-01 DOI:10.1017/S1460396922000097
Tabinda Sadaf, A. Rashid, Waqas Imam Bokhari, E. Samuel, A. Shahid, Raheel Mukhtar, Umair Zafar, K. Iqbal
{"title":"使用体积调制弧线治疗的全身照射,巴基斯坦一家癌症医院的经验","authors":"Tabinda Sadaf, A. Rashid, Waqas Imam Bokhari, E. Samuel, A. Shahid, Raheel Mukhtar, Umair Zafar, K. Iqbal","doi":"10.1017/S1460396922000097","DOIUrl":null,"url":null,"abstract":"Abstract Introduction: To report the planning parameters, efficacy and toxicity of total body irradiation using volumetric modulated arc therapy (VMAT). Methods: From July 2019 till May 2021, nine patients treated with VMAT-based total body irradiation as a part of the myeloablative regimen for homologous stem cell transplant were evaluated. The CT acquisition, planning parameters, doses to target volume and critical structures were evaluated retrospectively. Results: Median age was 24 with median height 172 cm. Average Mean Lung dose was 9·5 Gy, mean dose to kidney was kidney dose 8·4 Gy, planning target volume (PTV) 95% was 98 % and mean heterogeneity index of PTV was 1·2 all patients. Total fraction delivery time including setup was 3·1 h while beam on time was 23 min. Main toxicity observed was mucositis and fatigue, while no Grade 3 or more acute radiation toxicity was observed. Conclusion: At our institution, high dose TBI performed with multi-isocentric VMAT is now a standard procedure. Though it is cumbersome and time-consuming process but VMAT offers an advantage of increased dose homogeneity in the target volume with reduction in doses to critical organs especially lungs and kidneys in comparison to standard source to skin distance technique, longer follow-up time is necessary to evaluate our method and long-term toxicity.","PeriodicalId":44597,"journal":{"name":"Journal of Radiotherapy in Practice","volume":null,"pages":null},"PeriodicalIF":0.3000,"publicationDate":"2022-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Total body irradiation using volumetric modulated arc therapy, experience of a cancer hospital in Pakistan\",\"authors\":\"Tabinda Sadaf, A. Rashid, Waqas Imam Bokhari, E. Samuel, A. Shahid, Raheel Mukhtar, Umair Zafar, K. Iqbal\",\"doi\":\"10.1017/S1460396922000097\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract Introduction: To report the planning parameters, efficacy and toxicity of total body irradiation using volumetric modulated arc therapy (VMAT). Methods: From July 2019 till May 2021, nine patients treated with VMAT-based total body irradiation as a part of the myeloablative regimen for homologous stem cell transplant were evaluated. The CT acquisition, planning parameters, doses to target volume and critical structures were evaluated retrospectively. Results: Median age was 24 with median height 172 cm. Average Mean Lung dose was 9·5 Gy, mean dose to kidney was kidney dose 8·4 Gy, planning target volume (PTV) 95% was 98 % and mean heterogeneity index of PTV was 1·2 all patients. Total fraction delivery time including setup was 3·1 h while beam on time was 23 min. Main toxicity observed was mucositis and fatigue, while no Grade 3 or more acute radiation toxicity was observed. Conclusion: At our institution, high dose TBI performed with multi-isocentric VMAT is now a standard procedure. Though it is cumbersome and time-consuming process but VMAT offers an advantage of increased dose homogeneity in the target volume with reduction in doses to critical organs especially lungs and kidneys in comparison to standard source to skin distance technique, longer follow-up time is necessary to evaluate our method and long-term toxicity.\",\"PeriodicalId\":44597,\"journal\":{\"name\":\"Journal of Radiotherapy in Practice\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.3000,\"publicationDate\":\"2022-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Radiotherapy in Practice\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/S1460396922000097\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Radiotherapy in Practice","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/S1460396922000097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

摘要

摘要简介:报道体积调制电弧治疗(VMAT)全身照射的计划参数、疗效和毒性。方法:从2019年7月到2021年5月,对9例患者进行基于vmat的全身照射治疗,作为骨髓清除方案的一部分,用于同源干细胞移植。回顾性评价CT采集、规划参数、靶体积剂量及关键结构。结果:中位年龄24岁,中位身高172 cm。肺平均剂量为9.5 Gy,肾平均剂量为8.4 Gy,计划靶体积(PTV) 95%为98%,PTV平均异质性指数为1.2。包括设置在内的总剂量递送时间为3.1 h,光束到达时间为23 min。观察到的主要毒性是粘膜炎和疲劳,未观察到3级或以上的急性辐射毒性。结论:在我们的机构,采用多等中心VMAT进行高剂量TBI现在是一种标准程序。虽然这是一个繁琐和耗时的过程,但VMAT的优势在于,与标准源到皮肤距离技术相比,它增加了靶体积的剂量均匀性,减少了对关键器官(尤其是肺和肾脏)的剂量,需要更长的随访时间来评估我们的方法和长期毒性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Total body irradiation using volumetric modulated arc therapy, experience of a cancer hospital in Pakistan
Abstract Introduction: To report the planning parameters, efficacy and toxicity of total body irradiation using volumetric modulated arc therapy (VMAT). Methods: From July 2019 till May 2021, nine patients treated with VMAT-based total body irradiation as a part of the myeloablative regimen for homologous stem cell transplant were evaluated. The CT acquisition, planning parameters, doses to target volume and critical structures were evaluated retrospectively. Results: Median age was 24 with median height 172 cm. Average Mean Lung dose was 9·5 Gy, mean dose to kidney was kidney dose 8·4 Gy, planning target volume (PTV) 95% was 98 % and mean heterogeneity index of PTV was 1·2 all patients. Total fraction delivery time including setup was 3·1 h while beam on time was 23 min. Main toxicity observed was mucositis and fatigue, while no Grade 3 or more acute radiation toxicity was observed. Conclusion: At our institution, high dose TBI performed with multi-isocentric VMAT is now a standard procedure. Though it is cumbersome and time-consuming process but VMAT offers an advantage of increased dose homogeneity in the target volume with reduction in doses to critical organs especially lungs and kidneys in comparison to standard source to skin distance technique, longer follow-up time is necessary to evaluate our method and long-term toxicity.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Journal of Radiotherapy in Practice
Journal of Radiotherapy in Practice RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
0.80
自引率
0.00%
发文量
36
期刊介绍: Journal of Radiotherapy in Practice is a peer-reviewed journal covering all of the current modalities specific to clinical oncology and radiotherapy. The journal aims to publish research from a wide range of styles and encourage debate and the exchange of information and opinion from within the field of radiotherapy practice and clinical oncology. The journal also aims to encourage technical evaluations and case studies as well as equipment reviews that will be of interest to an international radiotherapy audience.
期刊最新文献
Wobbling nature of gamma passing rate as a function of calibration field sizes in patient-specific quality assurance Secondary fragmentation and relative biological effectiveness (RBE) study using Bridge SOI microdosimeter: Monte Carlo simulation Keratin-based topical cream for radiation dermatitis during head and neck radiotherapy: a randomised, open-label pilot study. Single catheter 3d volume based hybrid inverse planning optimization in IVBT can improve organ sparing – CORRIGENDUM Dosimetric case study of 3-D FiF vs. VMAT techniques in the treatment of H/N tumour
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1