Fucilli Fulvio IM, Giovanni Giuseppe Di, Mastrorocco Alessandro, Ninni Matteo, Loprete Piero, Crudis Isa De, Marano Massimiliano, Santomauro Antonio, Fucilli Fabio
{"title":"ECOLAB“Drape ArmourTM”辐射防护在限制医疗人员在胃肠病学-介入放射治疗过程中暴露于电离辐射的眼透镜剂量的有效性调查","authors":"Fucilli Fulvio IM, Giovanni Giuseppe Di, Mastrorocco Alessandro, Ninni Matteo, Loprete Piero, Crudis Isa De, Marano Massimiliano, Santomauro Antonio, Fucilli Fabio","doi":"10.17352/2581-5407.000048","DOIUrl":null,"url":null,"abstract":"Objectives: To investigate the efficiency of the ECOLAB “Drape ArmourTM” device in limiting the eye-lens doses absorbed by healthcare personnel exposed to ionizing radiation, in a four-month trial during gastroenterology interventional radiology procedures. Methods: Eyelens doses measured with eye-lens dosimeters calibrated in terms of equivalent dose at 3 mm depth ( Hp(3) ) were collected and analyzed since 2016 along with the irradiation parameters (Dose Area Product - DAP). The eye-lens doses received during the four-month trial, have been compared with doses normally received, in the same conditions of irradiation, in the absence of the protection drape. Results: During the period of use of Drape ArmourTM, the average dose to the eye lens was estimated to be 0.73 mSv (St.dev = 0.40 mSv). The average dose to the eye lens, measured in the same four-month period, across different years from 2017 to 2021, was equal to 1.30 mSv (st. dev = 0.35 mSv). Conclusions: Results suggest the effectiveness of Drape ArmourTM in containing the doses to the eye lens. Keypoint: Limiting eye-lens doses to a maximum value of 20 mSv/year is a real challenge, especially in interventional radiologic facilities. The use of suitable radio-opaque drapes may help healthcare workers involved in such facilities. The aim of the work is to evaluate the efficiency of the ECOLAB “Drape ArmourTM” sterile mono-use drape.","PeriodicalId":73166,"journal":{"name":"Global journal of cancer therapy","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2022-10-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Investigation of the effectiveness of ECOLAB ’Drape ArmourTM’ Radiation Protection in limiting eye-lens doses of healthcare personnel exposed to ionizing radiation during gastroenterology - interventional radiology procedures\",\"authors\":\"Fucilli Fulvio IM, Giovanni Giuseppe Di, Mastrorocco Alessandro, Ninni Matteo, Loprete Piero, Crudis Isa De, Marano Massimiliano, Santomauro Antonio, Fucilli Fabio\",\"doi\":\"10.17352/2581-5407.000048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Objectives: To investigate the efficiency of the ECOLAB “Drape ArmourTM” device in limiting the eye-lens doses absorbed by healthcare personnel exposed to ionizing radiation, in a four-month trial during gastroenterology interventional radiology procedures. Methods: Eyelens doses measured with eye-lens dosimeters calibrated in terms of equivalent dose at 3 mm depth ( Hp(3) ) were collected and analyzed since 2016 along with the irradiation parameters (Dose Area Product - DAP). The eye-lens doses received during the four-month trial, have been compared with doses normally received, in the same conditions of irradiation, in the absence of the protection drape. Results: During the period of use of Drape ArmourTM, the average dose to the eye lens was estimated to be 0.73 mSv (St.dev = 0.40 mSv). The average dose to the eye lens, measured in the same four-month period, across different years from 2017 to 2021, was equal to 1.30 mSv (st. dev = 0.35 mSv). Conclusions: Results suggest the effectiveness of Drape ArmourTM in containing the doses to the eye lens. Keypoint: Limiting eye-lens doses to a maximum value of 20 mSv/year is a real challenge, especially in interventional radiologic facilities. The use of suitable radio-opaque drapes may help healthcare workers involved in such facilities. The aim of the work is to evaluate the efficiency of the ECOLAB “Drape ArmourTM” sterile mono-use drape.\",\"PeriodicalId\":73166,\"journal\":{\"name\":\"Global journal of cancer therapy\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-10-20\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Global journal of cancer therapy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.17352/2581-5407.000048\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Global journal of cancer therapy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.17352/2581-5407.000048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Investigation of the effectiveness of ECOLAB ’Drape ArmourTM’ Radiation Protection in limiting eye-lens doses of healthcare personnel exposed to ionizing radiation during gastroenterology - interventional radiology procedures
Objectives: To investigate the efficiency of the ECOLAB “Drape ArmourTM” device in limiting the eye-lens doses absorbed by healthcare personnel exposed to ionizing radiation, in a four-month trial during gastroenterology interventional radiology procedures. Methods: Eyelens doses measured with eye-lens dosimeters calibrated in terms of equivalent dose at 3 mm depth ( Hp(3) ) were collected and analyzed since 2016 along with the irradiation parameters (Dose Area Product - DAP). The eye-lens doses received during the four-month trial, have been compared with doses normally received, in the same conditions of irradiation, in the absence of the protection drape. Results: During the period of use of Drape ArmourTM, the average dose to the eye lens was estimated to be 0.73 mSv (St.dev = 0.40 mSv). The average dose to the eye lens, measured in the same four-month period, across different years from 2017 to 2021, was equal to 1.30 mSv (st. dev = 0.35 mSv). Conclusions: Results suggest the effectiveness of Drape ArmourTM in containing the doses to the eye lens. Keypoint: Limiting eye-lens doses to a maximum value of 20 mSv/year is a real challenge, especially in interventional radiologic facilities. The use of suitable radio-opaque drapes may help healthcare workers involved in such facilities. The aim of the work is to evaluate the efficiency of the ECOLAB “Drape ArmourTM” sterile mono-use drape.