仪器鞋垫评估前庭神经鞘瘤患者的步态

IF 3.4 Q2 ENGINEERING, BIOMEDICAL Wearable technologies Pub Date : 2023-05-10 eCollection Date: 2023-01-01 DOI:10.1017/wtc.2023.11
Stephen Leong, Bing M Teh, Ton Duong, Diane Hu, Alexander Chui, Jocelyn S Chen, Michael B Sisti, Tony J C Wang, Damiano Zanotto, Anil K Lalwani
{"title":"仪器鞋垫评估前庭神经鞘瘤患者的步态","authors":"Stephen Leong, Bing M Teh, Ton Duong, Diane Hu, Alexander Chui, Jocelyn S Chen, Michael B Sisti, Tony J C Wang, Damiano Zanotto, Anil K Lalwani","doi":"10.1017/wtc.2023.11","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Imbalance and gait disturbances are common in patients with vestibular schwannoma (VS) and can result in significant morbidity. Current methods for quantitative gait analysis are cumbersome and difficult to implement. Here, we use custom-engineered instrumented insoles to evaluate the gait of patients diagnosed with VS.</p><p><strong>Methods: </strong>Twenty patients with VS were recruited from otology, neurosurgery, and radiation oncology clinics at a tertiary referral center. Functional gait assessment (FGA), 2-minute walk test (2MWT), and uneven surface walk test (USWT) were performed. Custom-engineered instrumented insoles, equipped with an 8-cell force sensitive resistor (FSR) and a 9-degree-of-freedom inertial measurement unit (IMU), were used to collect stride-by-stride spatiotemporal gait parameters, from which mean values and coefficients of variation (CV) were determined for each patient.</p><p><strong>Results: </strong>FGA scores were significantly correlated with gait metrics obtained from the 2MWT and USWT, including stride length, stride velocity, normalized stride length, normalized stride velocity, stride length CV, and stride velocity CV. Tumor diameter was negatively associated with stride time and swing time on the 2MWT; no such association existed between tumor diameter and FGA or DHI.</p><p><strong>Conclusions: </strong>Instrumented insoles may unveil associations between VS tumor size and gait dysfunction that cannot be captured by standardized clinical assessments and self-reported questionnaires.</p>","PeriodicalId":75318,"journal":{"name":"Wearable technologies","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2023-05-10","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10936291/pdf/","citationCount":"0","resultStr":"{\"title\":\"Instrumented insoles for assessment of gait in patients with vestibular schwannoma.\",\"authors\":\"Stephen Leong, Bing M Teh, Ton Duong, Diane Hu, Alexander Chui, Jocelyn S Chen, Michael B Sisti, Tony J C Wang, Damiano Zanotto, Anil K Lalwani\",\"doi\":\"10.1017/wtc.2023.11\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Imbalance and gait disturbances are common in patients with vestibular schwannoma (VS) and can result in significant morbidity. Current methods for quantitative gait analysis are cumbersome and difficult to implement. Here, we use custom-engineered instrumented insoles to evaluate the gait of patients diagnosed with VS.</p><p><strong>Methods: </strong>Twenty patients with VS were recruited from otology, neurosurgery, and radiation oncology clinics at a tertiary referral center. Functional gait assessment (FGA), 2-minute walk test (2MWT), and uneven surface walk test (USWT) were performed. Custom-engineered instrumented insoles, equipped with an 8-cell force sensitive resistor (FSR) and a 9-degree-of-freedom inertial measurement unit (IMU), were used to collect stride-by-stride spatiotemporal gait parameters, from which mean values and coefficients of variation (CV) were determined for each patient.</p><p><strong>Results: </strong>FGA scores were significantly correlated with gait metrics obtained from the 2MWT and USWT, including stride length, stride velocity, normalized stride length, normalized stride velocity, stride length CV, and stride velocity CV. Tumor diameter was negatively associated with stride time and swing time on the 2MWT; no such association existed between tumor diameter and FGA or DHI.</p><p><strong>Conclusions: </strong>Instrumented insoles may unveil associations between VS tumor size and gait dysfunction that cannot be captured by standardized clinical assessments and self-reported questionnaires.</p>\",\"PeriodicalId\":75318,\"journal\":{\"name\":\"Wearable technologies\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2023-05-10\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10936291/pdf/\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Wearable technologies\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1017/wtc.2023.11\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2023/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"Q2\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Wearable technologies","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1017/wtc.2023.11","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2023/1/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

摘要背景前庭神经鞘瘤(VS)患者常见不平衡和步态障碍,可导致显著的发病率。目前用于定量步态分析的方法繁琐且难以实现。在这里,我们使用定制的工程器械鞋垫来评估被诊断为VS的患者的步态。方法20名VS患者来自三级转诊中心的耳科、神经外科和放射肿瘤学诊所。进行了功能步态评估(FGA)、2分钟步行测试(2MWT)和不均匀表面步行测试(USWT)。定制设计的仪器鞋垫配有8单元力敏电阻器(FSR)和9自由度惯性测量单元(IMU),用于逐步收集时空步态参数,根据这些参数确定每个患者的平均值和变异系数(CV)。结果FGA评分与2MWT和USWT获得的步态指标(包括步幅、步幅速度、标准化步幅、标准化步伐速度、步幅长度CV和步幅速度CV)显著相关。肿瘤直径与2MWT的步幅时间和摆动时间呈负相关;肿瘤直径与FGA或DHI之间不存在这种相关性。结论器械鞋垫可能揭示VS肿瘤大小与步态功能障碍之间的关联,而标准化临床评估和自我报告问卷无法捕捉到这些关联。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Instrumented insoles for assessment of gait in patients with vestibular schwannoma.

Background: Imbalance and gait disturbances are common in patients with vestibular schwannoma (VS) and can result in significant morbidity. Current methods for quantitative gait analysis are cumbersome and difficult to implement. Here, we use custom-engineered instrumented insoles to evaluate the gait of patients diagnosed with VS.

Methods: Twenty patients with VS were recruited from otology, neurosurgery, and radiation oncology clinics at a tertiary referral center. Functional gait assessment (FGA), 2-minute walk test (2MWT), and uneven surface walk test (USWT) were performed. Custom-engineered instrumented insoles, equipped with an 8-cell force sensitive resistor (FSR) and a 9-degree-of-freedom inertial measurement unit (IMU), were used to collect stride-by-stride spatiotemporal gait parameters, from which mean values and coefficients of variation (CV) were determined for each patient.

Results: FGA scores were significantly correlated with gait metrics obtained from the 2MWT and USWT, including stride length, stride velocity, normalized stride length, normalized stride velocity, stride length CV, and stride velocity CV. Tumor diameter was negatively associated with stride time and swing time on the 2MWT; no such association existed between tumor diameter and FGA or DHI.

Conclusions: Instrumented insoles may unveil associations between VS tumor size and gait dysfunction that cannot be captured by standardized clinical assessments and self-reported questionnaires.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
5.80
自引率
0.00%
发文量
0
审稿时长
11 weeks
期刊最新文献
Concurrent validity of inertial measurement units in range of motion measurements of upper extremity: A systematic review and meta-analysis. Acute suppression of lower limb spasm by sacral afferent stimulation for people with spinal cord injury: A pilot study GLULA: Linear attention-based model for efficient human activity recognition from wearable sensors Erratum: Validity of estimating center of pressure during walking and running with plantar load from a three-sensor wireless insole - ERRATUM. A novel neck brace to characterize neck mobility impairments following neck dissection in head and neck cancer patients - ADDENDUM.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1