地震作用下高层建筑桩-土-结构动力相互作用研究Ⅰ:对动力响应的影响

IF 1.4 4区 工程技术 Q3 ENGINEERING, CIVIL Latin American Journal of Solids and Structures Pub Date : 2021-02-17 DOI:10.1590/1679-78256223
Huai-feng Wang, Ru-lin Zhang
{"title":"地震作用下高层建筑桩-土-结构动力相互作用研究Ⅰ:对动力响应的影响","authors":"Huai-feng Wang, Ru-lin Zhang","doi":"10.1590/1679-78256223","DOIUrl":null,"url":null,"abstract":"Abstract The structure-soil-structure interaction (SSSI) between high-rise buildings is numerically investigated. ANSYS has been further developed for calculation in the frequency domain, in which hysteretic damping can be considered for both the soil and structure. This study is presented in two subsequent papers. In the first part, i.e., this paper, the variations in the story shear force, interstory drift angle, displacement, velocity and acceleration of the superstructure, the sway of the foundation, and the axial and shearing forces of the pile are presented. The major influencing factors are the excitation frequency of a harmonic wave or the frequency components of a seismic wave, shaking direction of an exciting wave and direction of the structure arrangement. Under harmonic waves, the interaction mainly occurs when the excitation frequency is 1-5 Hz. Under seismic waves, when the shaking direction of an exciting wave is perpendicular to the direction of the structure arrangement and the direction of the structure arrangement is parallel to the lateral axis of the structure, the influence on the superstructure is greatest.","PeriodicalId":18192,"journal":{"name":"Latin American Journal of Solids and Structures","volume":" ","pages":""},"PeriodicalIF":1.4000,"publicationDate":"2021-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"4","resultStr":"{\"title\":\"Dynamic structure-soil-structure interaction of piled high-rise buildings under earthquake excitations I: Influence on dynamic response\",\"authors\":\"Huai-feng Wang, Ru-lin Zhang\",\"doi\":\"10.1590/1679-78256223\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Abstract The structure-soil-structure interaction (SSSI) between high-rise buildings is numerically investigated. ANSYS has been further developed for calculation in the frequency domain, in which hysteretic damping can be considered for both the soil and structure. This study is presented in two subsequent papers. In the first part, i.e., this paper, the variations in the story shear force, interstory drift angle, displacement, velocity and acceleration of the superstructure, the sway of the foundation, and the axial and shearing forces of the pile are presented. The major influencing factors are the excitation frequency of a harmonic wave or the frequency components of a seismic wave, shaking direction of an exciting wave and direction of the structure arrangement. Under harmonic waves, the interaction mainly occurs when the excitation frequency is 1-5 Hz. Under seismic waves, when the shaking direction of an exciting wave is perpendicular to the direction of the structure arrangement and the direction of the structure arrangement is parallel to the lateral axis of the structure, the influence on the superstructure is greatest.\",\"PeriodicalId\":18192,\"journal\":{\"name\":\"Latin American Journal of Solids and Structures\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":1.4000,\"publicationDate\":\"2021-02-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"4\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Latin American Journal of Solids and Structures\",\"FirstCategoryId\":\"5\",\"ListUrlMain\":\"https://doi.org/10.1590/1679-78256223\",\"RegionNum\":4,\"RegionCategory\":\"工程技术\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"ENGINEERING, CIVIL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Latin American Journal of Solids and Structures","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1590/1679-78256223","RegionNum":4,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, CIVIL","Score":null,"Total":0}
引用次数: 4

摘要

摘要对高层建筑结构-土-结构相互作用进行了数值研究。进一步发展了ANSYS的频域计算,在频域计算中可以同时考虑土体和结构的滞回阻尼。这项研究在随后的两篇论文中提出。在第一部分,即本文中,介绍了上部结构的层剪力、层间位移角、位移、速度和加速度、基础的摇摆以及桩的轴力和剪力的变化。主要影响因素是谐波的激励频率或地震波的频率分量、激励波的震动方向和结构布置的方向。在谐波作用下,相互作用主要发生在激励频率为1 ~ 5 Hz时。在地震波作用下,当激励波的震动方向垂直于结构布置方向,结构布置方向平行于结构的横向轴线时,对上部结构的影响最大。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Dynamic structure-soil-structure interaction of piled high-rise buildings under earthquake excitations I: Influence on dynamic response
Abstract The structure-soil-structure interaction (SSSI) between high-rise buildings is numerically investigated. ANSYS has been further developed for calculation in the frequency domain, in which hysteretic damping can be considered for both the soil and structure. This study is presented in two subsequent papers. In the first part, i.e., this paper, the variations in the story shear force, interstory drift angle, displacement, velocity and acceleration of the superstructure, the sway of the foundation, and the axial and shearing forces of the pile are presented. The major influencing factors are the excitation frequency of a harmonic wave or the frequency components of a seismic wave, shaking direction of an exciting wave and direction of the structure arrangement. Under harmonic waves, the interaction mainly occurs when the excitation frequency is 1-5 Hz. Under seismic waves, when the shaking direction of an exciting wave is perpendicular to the direction of the structure arrangement and the direction of the structure arrangement is parallel to the lateral axis of the structure, the influence on the superstructure is greatest.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
2.80
自引率
8.30%
发文量
37
审稿时长
>12 weeks
期刊最新文献
Reliability-based design of reinforced concrete pipes to satisfy the TEBT Innovative Approach for Enhancing GLULAM Performance with Reinforcing Steel Bars: A BESO-based Study Sequential method of topological optimization in multi-component systems Coupling Modal Analysis with the BEM for the Transient Response of Bar Structures Interacting with Three-Dimensional Soil Profiles Experimental and Numerical Study on Ballistic Impact Response of Vehicle Tires
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1