ANALISIS KERUSAKAN PIPA BAFFLE PADA SISTEM换热器SUATU PROSES TRANSFER PANAS[换热过程中换热器系统上挡板管的失效分析]

IF 0.6 Q4 METALLURGY & METALLURGICAL ENGINEERING Metalurgija Pub Date : 2017-03-12 DOI:10.14203/metalurgi.v28i3.262
E. Febriyanti
{"title":"ANALISIS KERUSAKAN PIPA BAFFLE PADA SISTEM换热器SUATU PROSES TRANSFER PANAS[换热过程中换热器系统上挡板管的失效分析]","authors":"E. Febriyanti","doi":"10.14203/metalurgi.v28i3.262","DOIUrl":null,"url":null,"abstract":"FAILURE ANALYSIS OF BAFFLE TUBE ON HEAT EXCHANGER SYSTEM IN HEAT TRANSFER PROCESS. This paper discussed about combination between erosion attack and corrosion process as a factor cause of baffle tube leaking in heat exchanger system and given some solution to prevent similar case in future. Heat exchangers transfer heat from a hot fluid to a colder fluid through the combined mechanisms of conduction and forced convection. When the heat exchanger fail, all of the processing system could be affected. In this research the failed baffle tubes of heat exchanger were investigated by failure analysis methods to find the caused of the failure. Several examinations were carried out to the baffle tubes to obtain detailed data for analysis. Examinations are carried out such as visual and fractography, microstructure, hardness testing, chemical composition analysis of baffle tube material, SEM and EDS. Visual examination shows wall thinning which caused by erosion attack and corrosion product at outside surfaces of baffle tube. Additional data obtained from EDS analysis confirm aggresive / corrosive ion such as Sulphur ion (ion S 2) which spreaded around pipe surface investigated. Erosion attack is caused by steam burst from another pipe which have experienced leaking at steam drum. So, it can be concluded that the cause of failure are combination between erosion attack and corrosion process on the outside surfaces of baffle tube.","PeriodicalId":18462,"journal":{"name":"Metalurgija","volume":"28 1","pages":"185-194"},"PeriodicalIF":0.6000,"publicationDate":"2017-03-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"1","resultStr":"{\"title\":\"ANALISIS KERUSAKAN PIPA BAFFLE PADA SISTEM HEAT EXCHANGER SUATU PROSES TRANSFER PANAS[Failure Analysis of Baffle Tube on Heat Exchanger System in Heat Transfer Process]\",\"authors\":\"E. Febriyanti\",\"doi\":\"10.14203/metalurgi.v28i3.262\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"FAILURE ANALYSIS OF BAFFLE TUBE ON HEAT EXCHANGER SYSTEM IN HEAT TRANSFER PROCESS. This paper discussed about combination between erosion attack and corrosion process as a factor cause of baffle tube leaking in heat exchanger system and given some solution to prevent similar case in future. Heat exchangers transfer heat from a hot fluid to a colder fluid through the combined mechanisms of conduction and forced convection. When the heat exchanger fail, all of the processing system could be affected. In this research the failed baffle tubes of heat exchanger were investigated by failure analysis methods to find the caused of the failure. Several examinations were carried out to the baffle tubes to obtain detailed data for analysis. Examinations are carried out such as visual and fractography, microstructure, hardness testing, chemical composition analysis of baffle tube material, SEM and EDS. Visual examination shows wall thinning which caused by erosion attack and corrosion product at outside surfaces of baffle tube. Additional data obtained from EDS analysis confirm aggresive / corrosive ion such as Sulphur ion (ion S 2) which spreaded around pipe surface investigated. Erosion attack is caused by steam burst from another pipe which have experienced leaking at steam drum. So, it can be concluded that the cause of failure are combination between erosion attack and corrosion process on the outside surfaces of baffle tube.\",\"PeriodicalId\":18462,\"journal\":{\"name\":\"Metalurgija\",\"volume\":\"28 1\",\"pages\":\"185-194\"},\"PeriodicalIF\":0.6000,\"publicationDate\":\"2017-03-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Metalurgija\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.14203/metalurgi.v28i3.262\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q4\",\"JCRName\":\"METALLURGY & METALLURGICAL ENGINEERING\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metalurgija","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.14203/metalurgi.v28i3.262","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"METALLURGY & METALLURGICAL ENGINEERING","Score":null,"Total":0}
引用次数: 1

摘要

换热器系统挡板管在换热过程中的失效分析。本文讨论了冲刷和腐蚀过程的结合是导致换热器系统挡板管泄漏的因素,并提出了防止今后类似情况发生的解决方案。热交换器通过传导和强制对流的组合机制将热从热流体传递到冷流体。当热交换器发生故障时,所有的处理系统都可能受到影响。本研究采用失效分析方法对换热器折流板失效管进行了研究,找出了失效原因。对挡板管进行了多次检查,以获得详细的数据进行分析。进行了外观和断口形貌、微观结构、硬度测试、挡板管材料化学成分分析、SEM和EDS等检查。外观检查显示,挡板管外表面的侵蚀和腐蚀产物导致壁变薄。EDS分析获得的其他数据证实了聚集性/腐蚀性离子,如硫离子(离子S2),其分布在所研究的管道表面周围。侵蚀侵蚀是由另一个管道的蒸汽爆裂引起的,该管道在汽包处发生泄漏。因此,可以认为,失效的原因是导流板管外表面的侵蚀和腐蚀过程的结合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
ANALISIS KERUSAKAN PIPA BAFFLE PADA SISTEM HEAT EXCHANGER SUATU PROSES TRANSFER PANAS[Failure Analysis of Baffle Tube on Heat Exchanger System in Heat Transfer Process]
FAILURE ANALYSIS OF BAFFLE TUBE ON HEAT EXCHANGER SYSTEM IN HEAT TRANSFER PROCESS. This paper discussed about combination between erosion attack and corrosion process as a factor cause of baffle tube leaking in heat exchanger system and given some solution to prevent similar case in future. Heat exchangers transfer heat from a hot fluid to a colder fluid through the combined mechanisms of conduction and forced convection. When the heat exchanger fail, all of the processing system could be affected. In this research the failed baffle tubes of heat exchanger were investigated by failure analysis methods to find the caused of the failure. Several examinations were carried out to the baffle tubes to obtain detailed data for analysis. Examinations are carried out such as visual and fractography, microstructure, hardness testing, chemical composition analysis of baffle tube material, SEM and EDS. Visual examination shows wall thinning which caused by erosion attack and corrosion product at outside surfaces of baffle tube. Additional data obtained from EDS analysis confirm aggresive / corrosive ion such as Sulphur ion (ion S 2) which spreaded around pipe surface investigated. Erosion attack is caused by steam burst from another pipe which have experienced leaking at steam drum. So, it can be concluded that the cause of failure are combination between erosion attack and corrosion process on the outside surfaces of baffle tube.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Metalurgija
Metalurgija 工程技术-冶金工程
CiteScore
1.20
自引率
33.30%
发文量
64
审稿时长
4-8 weeks
期刊介绍: The journal Metalurgija is primary scientific periodical that publishes scientific papers (original papers, preliminary notes, reviewed papers) as well as professional papers from the area of basic, applicable and developing researching in metallurgy and boundary metallurgy areas (physics, chemistry, mechanical engineering). These papers relate to processing ferrous and non-ferrous metallurgy, treating investigating as well as testing of raw materials, semi products and products, especially in the area of improving new materials and possibilities of their implementation. The journal is the only national periodical of this kind in the Republic of Croatia and covers the scientific field of metallurgy, especially: physical metallurgy and materials; process metailurgy, (ferrous and non-ferrous); mechanical metallurgy (processing, power , etc.); related (adjoing) branches: mechanlcal engineering, chemistry, physics etc.
期刊最新文献
STUDY TO MICROSTRUCTURE AND MECHANICAL PROPERTIES OF Mg-Zn-Fe-Cu-Co AS HIGH ENTROPY ALLOYS FOR URETERAL IMPLANT APPLICATION Deposisi Kalsium Karbonat pada Ti-6Al-6Mo[CALCIUM CARBONATE DEPOSITION ON TI-6AL-6MO] THE PRODUCT CHARACTERISTICS OF TREATED-FERRONICKEL SLAG PRODUCED BY ALKALI FUSION AND CARBOTHERMIC PROCESS PENGARUH PENEMPAAN DAN PERLAKUAN PANAS TERHADAP SIFAT MEKANIK DAN KETAHANAN KOROSI PADA MODIFIKASI BAJA LATERIT A-588 STUDY OF INTERGRANULAR CORROSION ON NON-HEAT TREATABLE ALUMINUM ALLOYS IN A COMPRESSOR AFTER-COOLER
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1