{"title":"PDMS微流控装置表面处理提高小分子回收率的评价及其在朗格汉斯胰岛分泌代谢物监测中的应用","authors":"Ashley E. Lenhart, and , Robert T. Kennedy*, ","doi":"10.1021/acsmeasuresciau.3c00025","DOIUrl":null,"url":null,"abstract":"<p >Microfluidic devices are becoming an important tool for bioanalysis with applications including studying cell secretion, cell growth, and drug delivery. Small molecules such as drugs, cell products, or nutrients may partition into polydimethylsiloxane (PDMS), a commonly used material for microfluidic devices, potentially leading to poor recovery or inaccurate delivery of such chemicals. To decrease small-molecule partitioning, surface and bulk PDMS treatments have been developed; however, these have been tested on few analytes, or their biocompatibility are unknown. Studies often focus on one analyte, whereas a diversity of chemicals are of interest and possibly affected. In this study, 11 device treatments are tested and applied to 21 biologically relevant small molecules with a variety of chemical structures. Device treatments are characterized using water contact angle measurements and evaluated by measuring recovery of the 21 target analytes using liquid chromatography–mass spectrometry. 1,5-Dimethyl-1,5-diazaundecamethylene polymethobromide (polybrene), a positively charged polymer, produced the least hydrophilic surface and was found to provide the best recovery with most of the analytes having >50% recovery and up to 92% recovery; however, recovery varied by analyte highlighting the importance of analyte diversity rather than targeting a single analyte in evaluating treatments. A polybrene-treated device was applied to investigate secretion from pancreatic islets, which are micro-organs involved in glucose homeostasis and diabetes. Islets secrete small molecules that have been shown to modulate the secretion of islets’ main functional products, glucose-regulating hormones. The polybrene treatment enabled the detection of 20 target analytes from islets-on-chip during isosmotic and hypo-osmotic glucose perfusions and resulted in detection of more significant secretion changes compared to untreated PDMS.</p>","PeriodicalId":29800,"journal":{"name":"ACS Measurement Science Au","volume":"3 5","pages":"380–389"},"PeriodicalIF":4.6000,"publicationDate":"2023-08-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.acs.org/doi/epdf/10.1021/acsmeasuresciau.3c00025","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Surface Treatments of PDMS Microfluidic Devices for Improving Small-Molecule Recovery with Application to Monitoring Metabolites Secreted from Islets of Langerhans\",\"authors\":\"Ashley E. Lenhart, and , Robert T. Kennedy*, \",\"doi\":\"10.1021/acsmeasuresciau.3c00025\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p >Microfluidic devices are becoming an important tool for bioanalysis with applications including studying cell secretion, cell growth, and drug delivery. Small molecules such as drugs, cell products, or nutrients may partition into polydimethylsiloxane (PDMS), a commonly used material for microfluidic devices, potentially leading to poor recovery or inaccurate delivery of such chemicals. To decrease small-molecule partitioning, surface and bulk PDMS treatments have been developed; however, these have been tested on few analytes, or their biocompatibility are unknown. Studies often focus on one analyte, whereas a diversity of chemicals are of interest and possibly affected. In this study, 11 device treatments are tested and applied to 21 biologically relevant small molecules with a variety of chemical structures. Device treatments are characterized using water contact angle measurements and evaluated by measuring recovery of the 21 target analytes using liquid chromatography–mass spectrometry. 1,5-Dimethyl-1,5-diazaundecamethylene polymethobromide (polybrene), a positively charged polymer, produced the least hydrophilic surface and was found to provide the best recovery with most of the analytes having >50% recovery and up to 92% recovery; however, recovery varied by analyte highlighting the importance of analyte diversity rather than targeting a single analyte in evaluating treatments. A polybrene-treated device was applied to investigate secretion from pancreatic islets, which are micro-organs involved in glucose homeostasis and diabetes. Islets secrete small molecules that have been shown to modulate the secretion of islets’ main functional products, glucose-regulating hormones. The polybrene treatment enabled the detection of 20 target analytes from islets-on-chip during isosmotic and hypo-osmotic glucose perfusions and resulted in detection of more significant secretion changes compared to untreated PDMS.</p>\",\"PeriodicalId\":29800,\"journal\":{\"name\":\"ACS Measurement Science Au\",\"volume\":\"3 5\",\"pages\":\"380–389\"},\"PeriodicalIF\":4.6000,\"publicationDate\":\"2023-08-24\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://pubs.acs.org/doi/epdf/10.1021/acsmeasuresciau.3c00025\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ACS Measurement Science Au\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://pubs.acs.org/doi/10.1021/acsmeasuresciau.3c00025\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"CHEMISTRY, ANALYTICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Measurement Science Au","FirstCategoryId":"1085","ListUrlMain":"https://pubs.acs.org/doi/10.1021/acsmeasuresciau.3c00025","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
Evaluation of Surface Treatments of PDMS Microfluidic Devices for Improving Small-Molecule Recovery with Application to Monitoring Metabolites Secreted from Islets of Langerhans
Microfluidic devices are becoming an important tool for bioanalysis with applications including studying cell secretion, cell growth, and drug delivery. Small molecules such as drugs, cell products, or nutrients may partition into polydimethylsiloxane (PDMS), a commonly used material for microfluidic devices, potentially leading to poor recovery or inaccurate delivery of such chemicals. To decrease small-molecule partitioning, surface and bulk PDMS treatments have been developed; however, these have been tested on few analytes, or their biocompatibility are unknown. Studies often focus on one analyte, whereas a diversity of chemicals are of interest and possibly affected. In this study, 11 device treatments are tested and applied to 21 biologically relevant small molecules with a variety of chemical structures. Device treatments are characterized using water contact angle measurements and evaluated by measuring recovery of the 21 target analytes using liquid chromatography–mass spectrometry. 1,5-Dimethyl-1,5-diazaundecamethylene polymethobromide (polybrene), a positively charged polymer, produced the least hydrophilic surface and was found to provide the best recovery with most of the analytes having >50% recovery and up to 92% recovery; however, recovery varied by analyte highlighting the importance of analyte diversity rather than targeting a single analyte in evaluating treatments. A polybrene-treated device was applied to investigate secretion from pancreatic islets, which are micro-organs involved in glucose homeostasis and diabetes. Islets secrete small molecules that have been shown to modulate the secretion of islets’ main functional products, glucose-regulating hormones. The polybrene treatment enabled the detection of 20 target analytes from islets-on-chip during isosmotic and hypo-osmotic glucose perfusions and resulted in detection of more significant secretion changes compared to untreated PDMS.
期刊介绍:
ACS Measurement Science Au is an open access journal that publishes experimental computational or theoretical research in all areas of chemical measurement science. Short letters comprehensive articles reviews and perspectives are welcome on topics that report on any phase of analytical operations including sampling measurement and data analysis. This includes:Chemical Reactions and SelectivityChemometrics and Data ProcessingElectrochemistryElemental and Molecular CharacterizationImagingInstrumentationMass SpectrometryMicroscale and Nanoscale systemsOmics (Genomics Proteomics Metabonomics Metabolomics and Bioinformatics)Sensors and Sensing (Biosensors Chemical Sensors Gas Sensors Intracellular Sensors Single-Molecule Sensors Cell Chips Arrays Microfluidic Devices)SeparationsSpectroscopySurface analysisPapers dealing with established methods need to offer a significantly improved original application of the method.