基于改进滑模观测器的风机基准模型传感器故障重构

Mohammed Taouil, Abdelghani El Ougli, B. Tidhaf, Hafida Zrouri
{"title":"基于改进滑模观测器的风机基准模型传感器故障重构","authors":"Mohammed Taouil, Abdelghani El Ougli, B. Tidhaf, Hafida Zrouri","doi":"10.11591/ijece.v13i5.pp5066-5075","DOIUrl":null,"url":null,"abstract":"This paper proposes a fault diagnosis scheme applied to a wind turbine system. The technique used is based on a modified sliding mode observer (SMO), which permits the reconstruction of actuator and sensor faults. A wind turbine benchmark with a real sequence of wind speed is exploited to validate the proposed fault detection and diagnosis scheme. Rotor speed, generator speed, blade pitch angle, and generator torque have different orders of magnitude. As a result, the dedicated sensors are susceptible to faults of quite varying magnitudes, and estimating simultaneous sensor faults with accuracy using a classical SMO is difficult. To address this issue, some modifications are made to the classic SMO. In order to test the efficiency of the modified SMO, several sensor fault scenarios have been simulated, first in the case of separate faults and then in the case of simultaneous faults. The simulation results show that the sensor faults are isolated, detected, and reconstructed accurately in the case of separate faults. In the case of simultaneous faults, with the proposed modification of SMO, the faults are precisely isolated, detected, and reconstructed, even though they have quite different amplitudes; thus, the relative gap does not exceed 0.08% for the generator speed sensor fault.","PeriodicalId":38060,"journal":{"name":"International Journal of Electrical and Computer Engineering","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2023-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Sensor fault reconstruction for wind turbine benchmark model using a modified sliding mode observer\",\"authors\":\"Mohammed Taouil, Abdelghani El Ougli, B. Tidhaf, Hafida Zrouri\",\"doi\":\"10.11591/ijece.v13i5.pp5066-5075\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This paper proposes a fault diagnosis scheme applied to a wind turbine system. The technique used is based on a modified sliding mode observer (SMO), which permits the reconstruction of actuator and sensor faults. A wind turbine benchmark with a real sequence of wind speed is exploited to validate the proposed fault detection and diagnosis scheme. Rotor speed, generator speed, blade pitch angle, and generator torque have different orders of magnitude. As a result, the dedicated sensors are susceptible to faults of quite varying magnitudes, and estimating simultaneous sensor faults with accuracy using a classical SMO is difficult. To address this issue, some modifications are made to the classic SMO. In order to test the efficiency of the modified SMO, several sensor fault scenarios have been simulated, first in the case of separate faults and then in the case of simultaneous faults. The simulation results show that the sensor faults are isolated, detected, and reconstructed accurately in the case of separate faults. In the case of simultaneous faults, with the proposed modification of SMO, the faults are precisely isolated, detected, and reconstructed, even though they have quite different amplitudes; thus, the relative gap does not exceed 0.08% for the generator speed sensor fault.\",\"PeriodicalId\":38060,\"journal\":{\"name\":\"International Journal of Electrical and Computer Engineering\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2023-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Electrical and Computer Engineering\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11591/ijece.v13i5.pp5066-5075\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Computer Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Electrical and Computer Engineering","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11591/ijece.v13i5.pp5066-5075","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Computer Science","Score":null,"Total":0}
引用次数: 0

摘要

提出了一种适用于风力发电系统的故障诊断方案。所使用的技术是基于一个改进的滑模观测器(SMO),它允许重建执行器和传感器故障。利用具有真实风速序列的风力机基准来验证所提出的故障检测与诊断方案。转子转速、发电机转速、叶片俯仰角和发电机转矩有不同的数量级。因此,专用传感器容易受到相当大的变化幅度的故障,并且使用经典SMO精确估计同时传感器故障是困难的。为了解决这个问题,对经典的SMO进行了一些修改。为了测试改进的SMO算法的有效性,首先模拟了不同故障情况下的传感器故障,然后模拟了同时故障情况。仿真结果表明,在分离故障的情况下,传感器故障能够被准确地隔离、检测和重构。在同时发生故障的情况下,采用改进的SMO方法可以精确地隔离、检测和重建故障,即使它们的幅值相差很大;因此,发电机转速传感器故障的相对间隙不超过0.08%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Sensor fault reconstruction for wind turbine benchmark model using a modified sliding mode observer
This paper proposes a fault diagnosis scheme applied to a wind turbine system. The technique used is based on a modified sliding mode observer (SMO), which permits the reconstruction of actuator and sensor faults. A wind turbine benchmark with a real sequence of wind speed is exploited to validate the proposed fault detection and diagnosis scheme. Rotor speed, generator speed, blade pitch angle, and generator torque have different orders of magnitude. As a result, the dedicated sensors are susceptible to faults of quite varying magnitudes, and estimating simultaneous sensor faults with accuracy using a classical SMO is difficult. To address this issue, some modifications are made to the classic SMO. In order to test the efficiency of the modified SMO, several sensor fault scenarios have been simulated, first in the case of separate faults and then in the case of simultaneous faults. The simulation results show that the sensor faults are isolated, detected, and reconstructed accurately in the case of separate faults. In the case of simultaneous faults, with the proposed modification of SMO, the faults are precisely isolated, detected, and reconstructed, even though they have quite different amplitudes; thus, the relative gap does not exceed 0.08% for the generator speed sensor fault.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
International Journal of Electrical and Computer Engineering
International Journal of Electrical and Computer Engineering Computer Science-Computer Science (all)
CiteScore
4.10
自引率
0.00%
发文量
177
期刊介绍: International Journal of Electrical and Computer Engineering (IJECE) is the official publication of the Institute of Advanced Engineering and Science (IAES). The journal is open to submission from scholars and experts in the wide areas of electrical, electronics, instrumentation, control, telecommunication and computer engineering from the global world. The journal publishes original papers in the field of electrical, computer and informatics engineering which covers, but not limited to, the following scope: -Electronics: Electronic Materials, Microelectronic System, Design and Implementation of Application Specific Integrated Circuits (ASIC), VLSI Design, System-on-a-Chip (SoC) and Electronic Instrumentation Using CAD Tools, digital signal & data Processing, , Biomedical Transducers and instrumentation, Medical Imaging Equipment and Techniques, Biomedical Imaging and Image Processing, Biomechanics and Rehabilitation Engineering, Biomaterials and Drug Delivery Systems; -Electrical: Electrical Engineering Materials, Electric Power Generation, Transmission and Distribution, Power Electronics, Power Quality, Power Economic, FACTS, Renewable Energy, Electric Traction, Electromagnetic Compatibility, High Voltage Insulation Technologies, High Voltage Apparatuses, Lightning Detection and Protection, Power System Analysis, SCADA, Electrical Measurements; -Telecommunication: Modulation and Signal Processing for Telecommunication, Information Theory and Coding, Antenna and Wave Propagation, Wireless and Mobile Communications, Radio Communication, Communication Electronics and Microwave, Radar Imaging, Distributed Platform, Communication Network and Systems, Telematics Services and Security Network; -Control[...] -Computer and Informatics[...]
期刊最新文献
Ranking load in microgrid based on fuzzy analytic hierarchy process and technique for order of preference by similarity to ideal solution algorithm for load shedding problem Explainable extreme boosting model for breast cancer diagnosis Automatic optical inspection for detecting keycaps misplacement using Tesseract optical character recognition A thermally aware performance analysis of quantum cellular automata logic gates Technical and market evaluation of thermal generation power plants in the Colombia power system
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1