基于氧化还原和络合形成反应的辛伐他汀的定量测定

Q3 Physics and Astronomy Ecletica Quimica Pub Date : 2018-02-05 DOI:10.1590/S0100-46702008000200003
K. Basavaiah, O. Z. Devi
{"title":"基于氧化还原和络合形成反应的辛伐他汀的定量测定","authors":"K. Basavaiah, O. Z. Devi","doi":"10.1590/S0100-46702008000200003","DOIUrl":null,"url":null,"abstract":"Two sensitive spectrophotometric methods are described for the determination of simvastatin (SMT) in bulk drug and in tablets. The methods are based on the oxidation of SMT by a measured excess of cerium (IV) in acid medium followed by determination of unreacted oxidant by two different reaction schemes. In one procedure (method A), the residual cerium (IV) is reacted with a fixed concentration of fer- roin and the increase in absorbance is measured at 510 nm. The second approach (method B) involves the reduction of the unreacted cerium (IV) with a fixed quantity of iron (II), and the resulting iron (III) is com- plexed with thiocyanate and the absorbance measured at 470 nm. In both methods, the amount of cerium (IV) reacted corresponds to SMT concentration. The experimental conditions for both methods were opti- mized. In method A, the absorbance is found to increase linearly with SMT concentration (r = 0.9995) whereas in method B, the same decreased (r = -0.9943). The systems obey Beer's law for 0.6-7.5 and 0.5- 5.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 2.7 X 104 and 1.06 X 105 Lmol-1 cm-1, respectively; and the corresponding sandel sensitivity values are 0.0153 and 0.0039µg cm-2, respectively. The limit of detection (LOD) and quantification (LOQ) are reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of SMT in tablets and the results were statistically compared with those of the reference method by applying the Student's t-test and F-test. No interference was observed from the common excipients added to tablets. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard addition procedure.","PeriodicalId":35894,"journal":{"name":"Ecletica Quimica","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2018-02-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"6","resultStr":"{\"title\":\"Cerimetric determination of simvastatin in pharmaceuticals based on redox and complex formation reactions\",\"authors\":\"K. Basavaiah, O. Z. Devi\",\"doi\":\"10.1590/S0100-46702008000200003\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Two sensitive spectrophotometric methods are described for the determination of simvastatin (SMT) in bulk drug and in tablets. The methods are based on the oxidation of SMT by a measured excess of cerium (IV) in acid medium followed by determination of unreacted oxidant by two different reaction schemes. In one procedure (method A), the residual cerium (IV) is reacted with a fixed concentration of fer- roin and the increase in absorbance is measured at 510 nm. The second approach (method B) involves the reduction of the unreacted cerium (IV) with a fixed quantity of iron (II), and the resulting iron (III) is com- plexed with thiocyanate and the absorbance measured at 470 nm. In both methods, the amount of cerium (IV) reacted corresponds to SMT concentration. The experimental conditions for both methods were opti- mized. In method A, the absorbance is found to increase linearly with SMT concentration (r = 0.9995) whereas in method B, the same decreased (r = -0.9943). The systems obey Beer's law for 0.6-7.5 and 0.5- 5.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 2.7 X 104 and 1.06 X 105 Lmol-1 cm-1, respectively; and the corresponding sandel sensitivity values are 0.0153 and 0.0039µg cm-2, respectively. The limit of detection (LOD) and quantification (LOQ) are reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of SMT in tablets and the results were statistically compared with those of the reference method by applying the Student's t-test and F-test. No interference was observed from the common excipients added to tablets. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard addition procedure.\",\"PeriodicalId\":35894,\"journal\":{\"name\":\"Ecletica Quimica\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2018-02-05\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Ecletica Quimica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/S0100-46702008000200003\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Physics and Astronomy\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Ecletica Quimica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/S0100-46702008000200003","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Physics and Astronomy","Score":null,"Total":0}
引用次数: 6

摘要

介绍了两种灵敏分光光度法测定原料药和片剂中辛伐他汀含量的方法。该方法是基于在酸性介质中测量过量的铈(IV)对SMT的氧化,然后用两种不同的反应方案测定未反应的氧化剂。在一个程序(方法A)中,残余的铈(IV)与固定浓度的铁络合物反应,在510 nm处测量吸光度的增加。第二种方法(方法B)是用一定量的铁(II)还原未反应的铈(IV),得到的铁(III)与硫氰酸酯共络合,在470 nm处测量吸光度。在这两种方法中,铈(IV)的反应量与SMT的浓度相对应。对两种方法的实验条件进行了优化。在方法A中,发现吸光度随SMT浓度线性增加(r = 0.9995),而在方法B中,吸光度下降(r = -0.9943)。方法A和方法B的浓度分别为0.6-7.5µg mL-1和0.5- 5.0µg mL-1,符合Beer定律。计算得到的摩尔吸光度值分别为2.7 × 104和1.06 × 105 Lmol-1 cm-1;相应的桑德尔灵敏度值分别为0.0153和0.0039µg cm-2。报告了两种方法的检出限(LOD)和定量(LOQ)。根据现行ICH指南确定了方法的日内和日内精密度和准确性。将该方法成功应用于片剂中SMT的测定,并通过学生t检验和f检验与参考方法的结果进行了统计学比较。片剂中常用辅料未见干扰。通过标准加成法进行回收率实验,进一步确定了方法的准确性和有效性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Cerimetric determination of simvastatin in pharmaceuticals based on redox and complex formation reactions
Two sensitive spectrophotometric methods are described for the determination of simvastatin (SMT) in bulk drug and in tablets. The methods are based on the oxidation of SMT by a measured excess of cerium (IV) in acid medium followed by determination of unreacted oxidant by two different reaction schemes. In one procedure (method A), the residual cerium (IV) is reacted with a fixed concentration of fer- roin and the increase in absorbance is measured at 510 nm. The second approach (method B) involves the reduction of the unreacted cerium (IV) with a fixed quantity of iron (II), and the resulting iron (III) is com- plexed with thiocyanate and the absorbance measured at 470 nm. In both methods, the amount of cerium (IV) reacted corresponds to SMT concentration. The experimental conditions for both methods were opti- mized. In method A, the absorbance is found to increase linearly with SMT concentration (r = 0.9995) whereas in method B, the same decreased (r = -0.9943). The systems obey Beer's law for 0.6-7.5 and 0.5- 5.0 µg mL-1 for method A and method B, respectively. The calculated molar absorptivity values are 2.7 X 104 and 1.06 X 105 Lmol-1 cm-1, respectively; and the corresponding sandel sensitivity values are 0.0153 and 0.0039µg cm-2, respectively. The limit of detection (LOD) and quantification (LOQ) are reported for both methods. Intra-day and inter-day precision, and accuracy of the methods were established as per the current ICH guidelines. The methods were successfully applied to the determination of SMT in tablets and the results were statistically compared with those of the reference method by applying the Student's t-test and F-test. No interference was observed from the common excipients added to tablets. The accuracy and validity of the methods were further ascertained by performing recovery experiments via standard addition procedure.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Ecletica Quimica
Ecletica Quimica Chemistry-Chemistry (all)
CiteScore
1.70
自引率
0.00%
发文量
32
审稿时长
28 weeks
期刊最新文献
Optimizing sewage water of Perum Pesona Permata Gading with the assistance of Cu/Mg electrodes as public street lighting based on green technology electricity Estimation of nitrogen dioxide levels on streets from Fortaleza Brazil using passive sampling and multivariate analysis Complex compound of trinitrotriamminecobalt(III): in theoretical studies In memoriam of Cecilia Laluce (1940 - 2023) Phytochemical screening, antiproliferative evaluation, and molecular docking studies of Acacia nilotica fruit from Nigeria
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1