MC-ICP-MS快速两柱分离法测定钡同位素组成

IF 3.4 2区 化学 Q1 SPECTROSCOPY Atomic Spectroscopy Pub Date : 2022-06-30 DOI:10.46770/as.2022.105
Kaiyun Chen
{"title":"MC-ICP-MS快速两柱分离法测定钡同位素组成","authors":"Kaiyun Chen","doi":"10.46770/as.2022.105","DOIUrl":null,"url":null,"abstract":": In recent years, the stable isotope composition of barium has emerged as a powerful tracer for understanding crucial geo-social processes; therefore, it is necessary to develop an efficient method for Ba isotopic ratios. Herein, we describe a rapid method for determining the isotopic ratios of Ba using a multi-collector inductively coupled plasma mass spectrometer in the low-resolution mode (Neptune Plus). In this method, the exact amount of the resin and the low eluted volume of the acid used in column purification significantly reduce the time required for Ba separation. Instrumental mass bias calibrations were performed for both standard-sample bracketing (SSB) and double-spike methods. The results show that the double-spike method provided Ba isotopic ratios with higher precision than the SSB technique. The effects of acid molarity and concentration mismatch, as well as the potential matrix effect, were investigated in the wet plasma mode. We evaluated the Ba isotopic compositions of ten geological reference materials, namely, BCR-2, BHVO-2, AGV-2, GSP-2, RGM-2, G-2, GSR-3, GSR-5, GSR-8, and GSR-11. Results indicated that these compositions were highly accurate with respect to the international Ba isotope standard, NIST SRM 3104a. Furthermore, the Ba isotopic compositions of most geological reference materials examined in this study agreed well with previously published data within the quoted analytical uncertainties. The long-term reproducibility analyses of all standards indicated that the obtained isotopic ratios were highly reproducible for δ 138/134 Ba, with precisions of ≤ ±0.05‰ (2SD). Compared to previous reports, we optimized the process of chemical purification, separated Ba samples faster, and improved the efficiency of the analyses employed in this study.","PeriodicalId":8642,"journal":{"name":"Atomic Spectroscopy","volume":null,"pages":null},"PeriodicalIF":3.4000,"publicationDate":"2022-06-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Rapid Two-Column Separation Method For Determining Barium Isotopic Compositions Using MC-ICP-MS\",\"authors\":\"Kaiyun Chen\",\"doi\":\"10.46770/as.2022.105\",\"DOIUrl\":null,\"url\":null,\"abstract\":\": In recent years, the stable isotope composition of barium has emerged as a powerful tracer for understanding crucial geo-social processes; therefore, it is necessary to develop an efficient method for Ba isotopic ratios. Herein, we describe a rapid method for determining the isotopic ratios of Ba using a multi-collector inductively coupled plasma mass spectrometer in the low-resolution mode (Neptune Plus). In this method, the exact amount of the resin and the low eluted volume of the acid used in column purification significantly reduce the time required for Ba separation. Instrumental mass bias calibrations were performed for both standard-sample bracketing (SSB) and double-spike methods. The results show that the double-spike method provided Ba isotopic ratios with higher precision than the SSB technique. The effects of acid molarity and concentration mismatch, as well as the potential matrix effect, were investigated in the wet plasma mode. We evaluated the Ba isotopic compositions of ten geological reference materials, namely, BCR-2, BHVO-2, AGV-2, GSP-2, RGM-2, G-2, GSR-3, GSR-5, GSR-8, and GSR-11. Results indicated that these compositions were highly accurate with respect to the international Ba isotope standard, NIST SRM 3104a. Furthermore, the Ba isotopic compositions of most geological reference materials examined in this study agreed well with previously published data within the quoted analytical uncertainties. The long-term reproducibility analyses of all standards indicated that the obtained isotopic ratios were highly reproducible for δ 138/134 Ba, with precisions of ≤ ±0.05‰ (2SD). Compared to previous reports, we optimized the process of chemical purification, separated Ba samples faster, and improved the efficiency of the analyses employed in this study.\",\"PeriodicalId\":8642,\"journal\":{\"name\":\"Atomic Spectroscopy\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":3.4000,\"publicationDate\":\"2022-06-30\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Atomic Spectroscopy\",\"FirstCategoryId\":\"92\",\"ListUrlMain\":\"https://doi.org/10.46770/as.2022.105\",\"RegionNum\":2,\"RegionCategory\":\"化学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"SPECTROSCOPY\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Atomic Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.46770/as.2022.105","RegionNum":2,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"SPECTROSCOPY","Score":null,"Total":0}
引用次数: 0

摘要

近年来,钡的稳定同位素组成已成为了解关键地质社会过程的有力示踪剂;因此,有必要开发一种有效的Ba同位素比值测定方法。在此,我们描述了一种在低分辨率模式下使用多收集器电感耦合等离子体质谱计(Neptune Plus)快速测定Ba同位素比率的方法。在这种方法中,精确的树脂量和在柱纯化中使用的低洗脱量的酸显着减少了Ba分离所需的时间。仪器质量偏差校准进行了标准样品包围法(SSB)和双尖峰法。结果表明,双尖峰法比SSB法提供的Ba同位素比值精度更高。在湿等离子体模式下,研究了酸的量浓度和浓度错配以及电位基质效应的影响。对BCR-2、BHVO-2、AGV-2、GSP-2、RGM-2、G-2、GSR-3、GSR-5、GSR-8、GSR-11等10种地质标准物质的Ba同位素组成进行了评价。结果表明,这些成分相对于国际Ba同位素标准NIST SRM 3104a具有很高的准确度。此外,本研究中检测的大多数地质参考物质的Ba同位素组成在引用的分析不确定度范围内与先前发表的数据一致。所有标准品的长期重复性分析表明,所获得的同位素比值对δ 138/134 Ba具有良好的重复性,精密度≤±0.05‰(2SD)。与以往的报道相比,我们优化了化学纯化的过程,更快地分离了Ba样品,提高了本研究的分析效率。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Rapid Two-Column Separation Method For Determining Barium Isotopic Compositions Using MC-ICP-MS
: In recent years, the stable isotope composition of barium has emerged as a powerful tracer for understanding crucial geo-social processes; therefore, it is necessary to develop an efficient method for Ba isotopic ratios. Herein, we describe a rapid method for determining the isotopic ratios of Ba using a multi-collector inductively coupled plasma mass spectrometer in the low-resolution mode (Neptune Plus). In this method, the exact amount of the resin and the low eluted volume of the acid used in column purification significantly reduce the time required for Ba separation. Instrumental mass bias calibrations were performed for both standard-sample bracketing (SSB) and double-spike methods. The results show that the double-spike method provided Ba isotopic ratios with higher precision than the SSB technique. The effects of acid molarity and concentration mismatch, as well as the potential matrix effect, were investigated in the wet plasma mode. We evaluated the Ba isotopic compositions of ten geological reference materials, namely, BCR-2, BHVO-2, AGV-2, GSP-2, RGM-2, G-2, GSR-3, GSR-5, GSR-8, and GSR-11. Results indicated that these compositions were highly accurate with respect to the international Ba isotope standard, NIST SRM 3104a. Furthermore, the Ba isotopic compositions of most geological reference materials examined in this study agreed well with previously published data within the quoted analytical uncertainties. The long-term reproducibility analyses of all standards indicated that the obtained isotopic ratios were highly reproducible for δ 138/134 Ba, with precisions of ≤ ±0.05‰ (2SD). Compared to previous reports, we optimized the process of chemical purification, separated Ba samples faster, and improved the efficiency of the analyses employed in this study.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Atomic Spectroscopy
Atomic Spectroscopy 物理-光谱学
CiteScore
5.30
自引率
14.70%
发文量
42
审稿时长
4.5 months
期刊介绍: The ATOMIC SPECTROSCOPY is a peer-reviewed international journal started in 1962 by Dr. Walter Slavin and now is published by Atomic Spectroscopy Press Limited (ASPL). It is intended for the rapid publication of both original articles and review articles in the fields of AAS, AFS, ICP-OES, ICP-MS, GD-MS, TIMS, SIMS, AMS, LIBS, XRF and related techniques. Manuscripts dealing with (i) instrumentation & fundamentals, (ii) methodology development & applications, and (iii) standard reference materials (SRMs) development can be submitted for publication.
期刊最新文献
Determination of REEs in Seawater RMs (NASS-7, CASS-6, and NMIJ 7204-A) Using Online Automated Separation ICP-MS Analysis System A Glimpse Into The Nature Of Particles Created During Pulsed Laser Ablation Of Arsenic Compounds In Ambient Gases Determination Of Sb Isotope Ratios In Stibnite Using Fs-LA-MC-ICP-MS And Two Potential Reference Materials Study Atom Probe Tomography Reveals Nano-Scale Organic Remaining In Conodont A Spectral Optimization Method To Enhance Handheld LIBS For T91 Aging Grade Classification Using Lorentzian Profile And Kalman Filter
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1