直流溅射超低负载金纳米膜电极检测水中As(III)

Tybur Q. Casuse, Angelica D. Benavidez, John B. Plumley, L. Tsui, Abdulmehdi Ali, J. Cerrato, F. Garzon
{"title":"直流溅射超低负载金纳米膜电极检测水中As(III)","authors":"Tybur Q. Casuse, Angelica D. Benavidez, John B. Plumley, L. Tsui, Abdulmehdi Ali, J. Cerrato, F. Garzon","doi":"10.1149/2754-2726/ac6d67","DOIUrl":null,"url":null,"abstract":"This study investigates the use of DC sputtering, physical vapor deposition as a facile method for creating ultralow loading, Au/C electrodes for use in the detection of As (III) in water. The sputtered nanofilm electrodes on carbon papers, substantially reduces the amount of Au consumed per electrode, <10 μg cm−2, compared to use of wire, foil, or screen-printed electrodes. Linear stripping voltammetry (LSV) was chosen for analytical simplicity and ease of automation. Electrodes using Au nanoparticles supported on Vulcan XC 72 R carbon were also investigated but were not viable for LSV analysis due to capacitive current charging of the high surface area carbon. The DC sputtered, Au nanofilm electrodes were used to create calibration curves for concentrations of As (III) between 5 and 50 μg l−1 and the standard addition method was used in a surface water sample with 5.5 μg l−1 total As. Peak areas plotted against concentration displayed strong linear correlation with meaningful detection below the USEPA maximum contaminant level (MCL) of 10 μg l−1. To our knowledge, this is the first study which utilizes the facile and mass manufacturable DC sputtering method to produce As (III) sensing electrodes. The results of this study have implications for the development of single use, low-cost nanofilm electrodes for field As (III) electroanalysis.","PeriodicalId":72870,"journal":{"name":"ECS sensors plus","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2022-05-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"5","resultStr":"{\"title\":\"DC Sputtered Ultralow Loading Gold Nanofilm Electrodes for Detection of As (III) in Water\",\"authors\":\"Tybur Q. Casuse, Angelica D. Benavidez, John B. Plumley, L. Tsui, Abdulmehdi Ali, J. Cerrato, F. Garzon\",\"doi\":\"10.1149/2754-2726/ac6d67\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"This study investigates the use of DC sputtering, physical vapor deposition as a facile method for creating ultralow loading, Au/C electrodes for use in the detection of As (III) in water. The sputtered nanofilm electrodes on carbon papers, substantially reduces the amount of Au consumed per electrode, <10 μg cm−2, compared to use of wire, foil, or screen-printed electrodes. Linear stripping voltammetry (LSV) was chosen for analytical simplicity and ease of automation. Electrodes using Au nanoparticles supported on Vulcan XC 72 R carbon were also investigated but were not viable for LSV analysis due to capacitive current charging of the high surface area carbon. The DC sputtered, Au nanofilm electrodes were used to create calibration curves for concentrations of As (III) between 5 and 50 μg l−1 and the standard addition method was used in a surface water sample with 5.5 μg l−1 total As. Peak areas plotted against concentration displayed strong linear correlation with meaningful detection below the USEPA maximum contaminant level (MCL) of 10 μg l−1. To our knowledge, this is the first study which utilizes the facile and mass manufacturable DC sputtering method to produce As (III) sensing electrodes. The results of this study have implications for the development of single use, low-cost nanofilm electrodes for field As (III) electroanalysis.\",\"PeriodicalId\":72870,\"journal\":{\"name\":\"ECS sensors plus\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2022-05-06\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"5\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ECS sensors plus\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1149/2754-2726/ac6d67\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ECS sensors plus","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1149/2754-2726/ac6d67","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 5

摘要

本研究探讨了使用直流溅射,物理气相沉积作为一种简便的方法来创建超低负载,用于检测水中as (III)的Au/C电极。与使用金属丝、箔或丝网印刷电极相比,在碳纸上溅射纳米膜电极大大减少了每个电极消耗的Au量,<10 μg cm - 2。采用线性溶出伏安法(LSV)分析简便,易于自动化。研究人员还研究了在Vulcan XC 72 R碳上负载金纳米颗粒的电极,但由于高表面积碳的容性电流充电,因此不适合进行LSV分析。采用直流溅射、Au纳米膜电极建立了As (III)浓度在5 ~ 50 μg l−1之间的校准曲线,并在总As为5.5 μg l−1的地表水样品中采用标准添加法。根据浓度绘制的峰面积与USEPA最大污染物水平(MCL)为10 μg l−1以下的有意义检测显示出很强的线性相关性。据我们所知,这是第一个利用简单和可批量制造的直流溅射方法生产As (III)传感电极的研究。这项研究的结果对开发单用途、低成本的纳米膜电极用于场As (III)电分析具有重要意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
DC Sputtered Ultralow Loading Gold Nanofilm Electrodes for Detection of As (III) in Water
This study investigates the use of DC sputtering, physical vapor deposition as a facile method for creating ultralow loading, Au/C electrodes for use in the detection of As (III) in water. The sputtered nanofilm electrodes on carbon papers, substantially reduces the amount of Au consumed per electrode, <10 μg cm−2, compared to use of wire, foil, or screen-printed electrodes. Linear stripping voltammetry (LSV) was chosen for analytical simplicity and ease of automation. Electrodes using Au nanoparticles supported on Vulcan XC 72 R carbon were also investigated but were not viable for LSV analysis due to capacitive current charging of the high surface area carbon. The DC sputtered, Au nanofilm electrodes were used to create calibration curves for concentrations of As (III) between 5 and 50 μg l−1 and the standard addition method was used in a surface water sample with 5.5 μg l−1 total As. Peak areas plotted against concentration displayed strong linear correlation with meaningful detection below the USEPA maximum contaminant level (MCL) of 10 μg l−1. To our knowledge, this is the first study which utilizes the facile and mass manufacturable DC sputtering method to produce As (III) sensing electrodes. The results of this study have implications for the development of single use, low-cost nanofilm electrodes for field As (III) electroanalysis.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
期刊最新文献
Review—Energy and Power Requirements for Wearable Sensors 3D Printed Carbon Nanotubes Reinforced Polydimethylsiloxane Flexible Sensors for Tactile Sensing Editors’ Choice—Review—Advances in Electrochemical Sensors: Improving Food Safety, Quality, and Traceability Field Testing of a Mixed Potential IoT Sensor Platform for Methane Quantification Automated Quantification of DNA Damage Using Deep Learning and Use of Synthetic Data Generated from Basic Geometric Shapes
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1