{"title":"利用时间分数导数分析非稳态非牛顿杰弗里血流和磁性纳米颗粒通过狭窄倾斜多孔动脉的运输","authors":"Habtamu Bayissa Yadeta, S. Shaw","doi":"10.1063/5.0165216","DOIUrl":null,"url":null,"abstract":"In the present study, a Caputo–Fabrizio (C–F) time-fractional derivative is introduced to the governing equations to present the flow of blood and the transport of magnetic nanoparticles (MNPs) through an inclined porous artery with mild stenosis. The rheology of blood is defined by the non-Newtonian visco-elastic Jeffrey fluid. The transport of MNPs is used as a drug delivery application for cardiovascular disorder therapy. The momentum and transport equations are solved analytically by using the Laplace transform and the finite Hankel transform along with their inverses, and the solutions are presented in the form of Laplace convolutions. To display the solutions graphically, the Laplace convolutions are solved using the numerical integration technique. The study presents the impacts of different governing parameters on blood and MNP velocities, volumetric flow rate, flow resistance, and skin friction. The study demonstrates that blood and MNP velocities boost with an increase in the fractional order parameter, Darcy number, and Jeffrey fluid parameter. The volumetric flow rate decreases and flow resistance increases with enhancement in stenosis height. The non-symmetric shape of stenosis and the rheology of blood decrease skin friction, whereas enhancement in MNP concentration increases skin friction. A comparison of the present result with the previous work shows excellent agreement. The present study will be beneficial for the field of medical science to further study atherosclerosis therapy and other similar disorders.","PeriodicalId":15088,"journal":{"name":"Journal of Applied Physics","volume":" ","pages":""},"PeriodicalIF":2.7000,"publicationDate":"2023-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Analysis of unsteady non-Newtonian Jeffrey blood flow and transport of magnetic nanoparticles through an inclined porous artery with stenosis using the time fractional derivative\",\"authors\":\"Habtamu Bayissa Yadeta, S. Shaw\",\"doi\":\"10.1063/5.0165216\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"In the present study, a Caputo–Fabrizio (C–F) time-fractional derivative is introduced to the governing equations to present the flow of blood and the transport of magnetic nanoparticles (MNPs) through an inclined porous artery with mild stenosis. The rheology of blood is defined by the non-Newtonian visco-elastic Jeffrey fluid. The transport of MNPs is used as a drug delivery application for cardiovascular disorder therapy. The momentum and transport equations are solved analytically by using the Laplace transform and the finite Hankel transform along with their inverses, and the solutions are presented in the form of Laplace convolutions. To display the solutions graphically, the Laplace convolutions are solved using the numerical integration technique. The study presents the impacts of different governing parameters on blood and MNP velocities, volumetric flow rate, flow resistance, and skin friction. The study demonstrates that blood and MNP velocities boost with an increase in the fractional order parameter, Darcy number, and Jeffrey fluid parameter. The volumetric flow rate decreases and flow resistance increases with enhancement in stenosis height. The non-symmetric shape of stenosis and the rheology of blood decrease skin friction, whereas enhancement in MNP concentration increases skin friction. A comparison of the present result with the previous work shows excellent agreement. The present study will be beneficial for the field of medical science to further study atherosclerosis therapy and other similar disorders.\",\"PeriodicalId\":15088,\"journal\":{\"name\":\"Journal of Applied Physics\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.7000,\"publicationDate\":\"2023-09-08\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of Applied Physics\",\"FirstCategoryId\":\"101\",\"ListUrlMain\":\"https://doi.org/10.1063/5.0165216\",\"RegionNum\":3,\"RegionCategory\":\"物理与天体物理\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"PHYSICS, APPLIED\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Applied Physics","FirstCategoryId":"101","ListUrlMain":"https://doi.org/10.1063/5.0165216","RegionNum":3,"RegionCategory":"物理与天体物理","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"PHYSICS, APPLIED","Score":null,"Total":0}
Analysis of unsteady non-Newtonian Jeffrey blood flow and transport of magnetic nanoparticles through an inclined porous artery with stenosis using the time fractional derivative
In the present study, a Caputo–Fabrizio (C–F) time-fractional derivative is introduced to the governing equations to present the flow of blood and the transport of magnetic nanoparticles (MNPs) through an inclined porous artery with mild stenosis. The rheology of blood is defined by the non-Newtonian visco-elastic Jeffrey fluid. The transport of MNPs is used as a drug delivery application for cardiovascular disorder therapy. The momentum and transport equations are solved analytically by using the Laplace transform and the finite Hankel transform along with their inverses, and the solutions are presented in the form of Laplace convolutions. To display the solutions graphically, the Laplace convolutions are solved using the numerical integration technique. The study presents the impacts of different governing parameters on blood and MNP velocities, volumetric flow rate, flow resistance, and skin friction. The study demonstrates that blood and MNP velocities boost with an increase in the fractional order parameter, Darcy number, and Jeffrey fluid parameter. The volumetric flow rate decreases and flow resistance increases with enhancement in stenosis height. The non-symmetric shape of stenosis and the rheology of blood decrease skin friction, whereas enhancement in MNP concentration increases skin friction. A comparison of the present result with the previous work shows excellent agreement. The present study will be beneficial for the field of medical science to further study atherosclerosis therapy and other similar disorders.
期刊介绍:
The Journal of Applied Physics (JAP) is an influential international journal publishing significant new experimental and theoretical results of applied physics research.
Topics covered in JAP are diverse and reflect the most current applied physics research, including:
Dielectrics, ferroelectrics, and multiferroics-
Electrical discharges, plasmas, and plasma-surface interactions-
Emerging, interdisciplinary, and other fields of applied physics-
Magnetism, spintronics, and superconductivity-
Organic-Inorganic systems, including organic electronics-
Photonics, plasmonics, photovoltaics, lasers, optical materials, and phenomena-
Physics of devices and sensors-
Physics of materials, including electrical, thermal, mechanical and other properties-
Physics of matter under extreme conditions-
Physics of nanoscale and low-dimensional systems, including atomic and quantum phenomena-
Physics of semiconductors-
Soft matter, fluids, and biophysics-
Thin films, interfaces, and surfaces