类药物机器人辅助手术系统的可行性研究

IF 2.3 4区 计算机科学 Q2 Computer Science International Journal of Advanced Robotic Systems Pub Date : 2023-05-01 DOI:10.1177/17298806231152704
G. Capovilla, E. Tagkalos, Caterina Froiio, E. Hadzijusufoviç, F. Berlth, P. Grimminger
{"title":"类药物机器人辅助手术系统的可行性研究","authors":"G. Capovilla, E. Tagkalos, Caterina Froiio, E. Hadzijusufoviç, F. Berlth, P. Grimminger","doi":"10.1177/17298806231152704","DOIUrl":null,"url":null,"abstract":"The hinotori™ surgical robotic system, by Medicaroid (Medicaroid Corporation, Kobe, Japan), is a new robotic system for minimally invasive surgery. We aimed at evaluating its usability and accessibility in a preclinical setting. This was a preclinical feasibility study. Two groups of surgeons, one with three experienced robotic surgeons (group 1) and one with three robotic-surgery naive participants (group 2), performed the following tasks using the hinotori™ system in a simulated preclinical setting: console setup, docking, instrument exchange, undocking, and suturing. Each participant repeated each task three times. The time required for performing each repetition and the count of failed repetitions were the primary outcomes of the study. The subjectively perceived workload in performing the tasks, as measured by the NASA-TLX score, was the secondary outcome. The improvement of participants within the three repetitions as well as a comparison between the performances of group 1 and 2 were evaluated. The time required to perform each task decreased with repetitions for both groups, so did the subjective workload score. The time measures required to perform the tasks and the mental effort scores were comparable between the two groups for the console setup, docking, instrument exchange, and undocking tasks. The NASA-TLX score was also comparable between the two groups for the console setup and the emergency undocking tasks and decreased significantly within all tasks after the third repetition. The incidence of failed repetitions was higher in group 2 for the suturing task, however the difference was not statistically significant. The results confirmed the usability of the hinotori™ system in a preclinical setting for both highly trained surgeons and nonexperienced operators and its accessibility for both long-time users of other systems and first-time users.","PeriodicalId":50343,"journal":{"name":"International Journal of Advanced Robotic Systems","volume":" ","pages":""},"PeriodicalIF":2.3000,"publicationDate":"2023-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Medicaroid robotic assisted surgery system: A feasibility study\",\"authors\":\"G. Capovilla, E. Tagkalos, Caterina Froiio, E. Hadzijusufoviç, F. Berlth, P. Grimminger\",\"doi\":\"10.1177/17298806231152704\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"The hinotori™ surgical robotic system, by Medicaroid (Medicaroid Corporation, Kobe, Japan), is a new robotic system for minimally invasive surgery. We aimed at evaluating its usability and accessibility in a preclinical setting. This was a preclinical feasibility study. Two groups of surgeons, one with three experienced robotic surgeons (group 1) and one with three robotic-surgery naive participants (group 2), performed the following tasks using the hinotori™ system in a simulated preclinical setting: console setup, docking, instrument exchange, undocking, and suturing. Each participant repeated each task three times. The time required for performing each repetition and the count of failed repetitions were the primary outcomes of the study. The subjectively perceived workload in performing the tasks, as measured by the NASA-TLX score, was the secondary outcome. The improvement of participants within the three repetitions as well as a comparison between the performances of group 1 and 2 were evaluated. The time required to perform each task decreased with repetitions for both groups, so did the subjective workload score. The time measures required to perform the tasks and the mental effort scores were comparable between the two groups for the console setup, docking, instrument exchange, and undocking tasks. The NASA-TLX score was also comparable between the two groups for the console setup and the emergency undocking tasks and decreased significantly within all tasks after the third repetition. The incidence of failed repetitions was higher in group 2 for the suturing task, however the difference was not statistically significant. The results confirmed the usability of the hinotori™ system in a preclinical setting for both highly trained surgeons and nonexperienced operators and its accessibility for both long-time users of other systems and first-time users.\",\"PeriodicalId\":50343,\"journal\":{\"name\":\"International Journal of Advanced Robotic Systems\",\"volume\":\" \",\"pages\":\"\"},\"PeriodicalIF\":2.3000,\"publicationDate\":\"2023-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International Journal of Advanced Robotic Systems\",\"FirstCategoryId\":\"94\",\"ListUrlMain\":\"https://doi.org/10.1177/17298806231152704\",\"RegionNum\":4,\"RegionCategory\":\"计算机科学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q2\",\"JCRName\":\"Computer Science\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International Journal of Advanced Robotic Systems","FirstCategoryId":"94","ListUrlMain":"https://doi.org/10.1177/17298806231152704","RegionNum":4,"RegionCategory":"计算机科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"Computer Science","Score":null,"Total":0}
引用次数: 0

摘要

日本™ Medicaroid(Medicaroid Corporation,Kobe,Japan)的手术机器人系统是一种用于微创手术的新型机器人系统。我们旨在评估其在临床前环境中的可用性和可访问性。这是一项临床前可行性研究。两组外科医生,一组有三名经验丰富的机器人外科医生(第1组),另一组有3名机器人手术新手(第2组),使用hinotori执行了以下任务™ 模拟临床前环境中的系统:控制台设置、对接、仪器交换、脱离对接和缝合。每个参与者将每个任务重复三次。每次重复所需的时间和失败重复的次数是研究的主要结果。通过NASA-TLX评分衡量,执行任务时主观感知的工作量是次要结果。评估了参与者在三次重复中的进步以及第1组和第2组表现之间的比较。两组完成每项任务所需的时间都随着重复次数的增加而减少,主观工作量得分也随之减少。在控制台设置、对接、仪器交换和脱离对接任务中,两组执行任务所需的时间测量和脑力劳动得分具有可比性。两组在控制台设置和紧急脱离对接任务方面的NASA-TLX得分也具有可比性,并且在第三次重复后的所有任务中都显著下降。第2组缝合任务重复失败的发生率较高,但差异无统计学意义。结果证实了hinotori的可用性™ 该系统在临床前环境中为训练有素的外科医生和无经验的操作员提供,并为其他系统的长期用户和首次用户提供可访问性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
查看原文
分享 分享
微信好友 朋友圈 QQ好友 复制链接
本刊更多论文
Medicaroid robotic assisted surgery system: A feasibility study
The hinotori™ surgical robotic system, by Medicaroid (Medicaroid Corporation, Kobe, Japan), is a new robotic system for minimally invasive surgery. We aimed at evaluating its usability and accessibility in a preclinical setting. This was a preclinical feasibility study. Two groups of surgeons, one with three experienced robotic surgeons (group 1) and one with three robotic-surgery naive participants (group 2), performed the following tasks using the hinotori™ system in a simulated preclinical setting: console setup, docking, instrument exchange, undocking, and suturing. Each participant repeated each task three times. The time required for performing each repetition and the count of failed repetitions were the primary outcomes of the study. The subjectively perceived workload in performing the tasks, as measured by the NASA-TLX score, was the secondary outcome. The improvement of participants within the three repetitions as well as a comparison between the performances of group 1 and 2 were evaluated. The time required to perform each task decreased with repetitions for both groups, so did the subjective workload score. The time measures required to perform the tasks and the mental effort scores were comparable between the two groups for the console setup, docking, instrument exchange, and undocking tasks. The NASA-TLX score was also comparable between the two groups for the console setup and the emergency undocking tasks and decreased significantly within all tasks after the third repetition. The incidence of failed repetitions was higher in group 2 for the suturing task, however the difference was not statistically significant. The results confirmed the usability of the hinotori™ system in a preclinical setting for both highly trained surgeons and nonexperienced operators and its accessibility for both long-time users of other systems and first-time users.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
CiteScore
6.50
自引率
0.00%
发文量
65
审稿时长
6 months
期刊介绍: International Journal of Advanced Robotic Systems (IJARS) is a JCR ranked, peer-reviewed open access journal covering the full spectrum of robotics research. The journal is addressed to both practicing professionals and researchers in the field of robotics and its specialty areas. IJARS features fourteen topic areas each headed by a Topic Editor-in-Chief, integrating all aspects of research in robotics under the journal''s domain.
期刊最新文献
Expanded photo-model-based stereo vision pose estimation using a shooting distance unknown photo Enhanced lightweight deep network for efficient livestock detection in grazing areas Manipulate mechanism design and synchronous motion application for driving simulator A general method for the manipulability analysis of serial robot manipulators Design, simulation, and experiment for the end effector of a spherical fruit picking robot
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
现在去查看 取消
×
提示
确定
0
微信
客服QQ
Book学术公众号 扫码关注我们
反馈
×
意见反馈
请填写您的意见或建议
请填写您的手机或邮箱
已复制链接
已复制链接
快去分享给好友吧!
我知道了
×
扫码分享
扫码分享
Book学术官方微信
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术
文献互助 智能选刊 最新文献 互助须知 联系我们:info@booksci.cn
Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。
Copyright © 2023 Book学术 All rights reserved.
ghs 京公网安备 11010802042870号 京ICP备2023020795号-1